Datalogger with 2.4 GHz Spread Spectrum Radio

Datalogger with 2.4 GHz Spread Spectrum Radio
Archive
Archive

Datalogger with 2.4 GHz Spread Spectrum Radio

Retired

No longer available to order

This product is retained for service, documentation, and compatibility information.

Replaced by

  • CR300

    Measurement and Control Datalogger

  • CR310

    Measurement and Control Datalogger

Overview

The CR215 was a small, low-cost data logger with an internal 2.4 GHz spread spectrum radio. It was replaced by the CR216, has improved communication capability. The CR215 can be used within a CR216(X) network, but the CR216(X) needs to be in the transparent mode. Contact one of our application engineers for details.

Benefits

  • On-board 12 Vdc lead acid battery charger

Specifications

A/D Converter
12 bit
Maximum Scan Rate
Once per second
Single-Ended Analog Channels
5, individually configured
Analog Voltage Range
0 to +2500 mV
Measurement Resolution
0.6 mV
Excitation Channels
2

(programmable for either +2.5 or +5 volts)

Switched Battery Port
1
Pulse Count Channels
2
Control Ports
2
Battery Voltage Range
7 to 16 Vdc
Communications
RS-232

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Communications

The CR215's internal spread spectrum radio can transmit data to other CR215 loggers or RF415 radios. It can also communicate with CR216(X) loggers, RF416 radios, or RF432 radios if they are set to the transparent mode. Certain CR215 settings must match the radio's settings for communications between the data logger and radio to be successful. The factory default settings of these devices might not match; therefore, they may need to be reconfigured before communications can take place. 

The CR215 can communicate with a PC via direct connect, NL100 Ethernet interface, MD485 multidrop modem, and digital cellular modems. Data can be viewed on the CD295 DataView II display, Archer-PCon Field PC, or a user-supplied PDA (PConnect or PConnectCE software required).

Measurement & Control Peripherals

The CR215 is not compatible with SDM devices and multiplexers.

Sensors

The CR215 can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.

Enclosures

Applications with minimal power requirements can use the ENC200 enclosure to house the data logger and the #16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the #16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR215-based systems.

Power Supplies

The CR215 uses an external power supply and has a built-in regulator. When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 Ahr or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.

Compatible Products

(55)

Related Resources

Product Life Events

Available for Order
September 17, 2002
Calibration Available Until
September 15, 2005
Retired
September 15, 2005
Free Support Until
December 31, 2019
End of Life
December 31, 2019
Repair Available Until
December 31, 2019