The CS455 is a pressure transducer for for water level measurements in canals, wells, ponds, harbors, lakes, streams and tanks. It has a rugged titanium case that allows it to be used in saltwater and other harsh environments. The CS455 outputs either a digital SDI-12 or RS-232 signal to indicate observed pressure and temperature. This output can be read by many of our data loggers.
Key Advantages
Ideal for long-term deployment in harsh conditions
Technical Description
The CS455 consists of a piezoresistive sensor and a temperature sensor housed in a titanium case. It has a rugged Hytrel cable that remains flexible, even under harsh environmental conditions. The cable incorporates a vent tube to compensate for atmospheric pressure fluctuations. The vent tube terminates inside a desiccant tube, which prevents water vapor from entering the inner cavity of the transducer.
The CS455 has several pressure range options and two accuracy options (see Ordering Info). The standard accuracy option provides ±0.1% FS TEB over the 0° to 60°C temperature range. The high accuracy option provides ±0.05% FS TEB over the 0° to 60°C temperature range and includes a calibration certificate. TEB is the combined errors due to nonlinearity, hysteresis, non-repeatability, and thermal effects over the compensated temperature range, per ISA S51.1. Please note that the high accuracy option is not available for the 0 to 2.9 psig range option.
Campbell Scientific offers the A150 Desiccated Case that allows the CS455 to be connected to a CWS900 Wireless Sensor Interface (for use in a wireless sensor network) or to be connected to a prewired enclosure (see Ordering Information).
Product Notes
Benefits
- Rugged titanium case protects piezoresistive sensor allowing it to be used in saltwater and other harsh environments
- Quality construction ensures product reliability
- Low-power sleep state between measurements reduces power consumption
- Fully temperature-compensated
- Optional weighted nose cone facilitates submersion
- Compatible with most Campbell Scientific data loggers
- NPT fitting allows it to be used in closed-pipe applications
- Quick shipment after receipt of order (ARO)
- Compatible with the A150 Desiccated Case, which allows it to be connected to the CWS900 and used in a wireless sensor network
Specifications
- Measurement Time
- < 1.5 s
- Outputs
- SDI-12 (version 1.3) 1200 bps; RS-232 9600 bps
- Resolution
- 0.0035% FS
- Operating Temperature
- -10° to +80°C
- Compensated Temperature
- 0° to 60°C
- Temperature Accuracy
- ±0.2°C
- Overpressure
- 2 x pressure range
- Power Requirements
- 6 to 18 Vdc
- Accuracy with Standard Accuracy Option
- ±0.1% FS TEB
(Includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range, per ISA S51.1.)
- Accuracy with High Accuracy Option
- ±0.05% FS TEB
(The high accuracy [±0.05% FS] option is not available for the 0 to 2.9 psig range option.)
- Cable Type
- Hytrel Jacket, five conductor, 26 AWG
- NPT Fitting
- 1/4-in. NPS
- Top Cone Material
- Delrin
- Body Material
- Titanium
- Element Material
- Hastelloy
- Diameter
- 2.13 cm
(0.84 in.)
- Length
- 21.34 cm
(8.4 in.)
- Distance
- 2.86 cm
(1.13 in.) from black line etched on housing to end of NPT fitting
4 cm(1.58 in.) from black line etched on housing to end of standard nose cone
11.59 cm(4.56 in.) from black line etched on housing to end of weighted nose cone
- Weight without Cable
- 0.11 kg
(0.25 lb)
- Cable Weight
- 0.421 kg/m
(0.283 lb/ft)
- Weight
- 0.211 kg
(0.465 lb) for 25414 Weighted Nose Cone
Power Consumption
- Quiescent
- < 80 µA
- Measurement/Communication
- 8 mA
(1-s measurement)
- Maximum
- 40 mA
Pressure Measurement Range
- Option -2
- Up to 2.9 psig
(20 kPa)
- Option -7
- Up to 7.25 psig
(50 kPa)
- Option -14
- Up to 14.5 psig
(100 kPa)
- Option -29
- Up to 29 psig
(200 kPa)
- Option -72
- Up to 72.5 psig
(500 kPa)
- Option -145
- Up to 145 psig
(1000 kPa)
Depth of Fresh Water Measurement Range
- Option -2
- Up to 2.0 m
(6.7 ft)
- Option -7
- Up to 5.1 m
(16.7 ft)
- Option -14
- Up to 10.2 m
(33.4 ft)
- Option -29
- Up to 20.4 m
(67 ft)
- Option -72
- Up to 50.9 m
(167 ft)
- Option -145
- Up to 102 m
(334.5 ft)
Maximum Cable Length
- SDI-12 (1 sensor connected to a single port)
- ~457 m
(1500 ft)
- SDI-12 (10 sensors connected to a single port)
- 60 m
(200 ft)
- RS-232
- 60 m
(200 ft)
Other Accessories
(4)
25414
Weighted Nose Cone for CS450 or CS455
The 25414 nose cone adds 0.465 lbs (0.211 kg) of weight to the CS455. Additional weight makes the transducer easier to submerge to depth.
Orderable
25431
Split Mesh Cable Grip, 0.180 to 0.250
The 25431 Split Mesh Cable grip is recommended for use in wells to center the cable and to provide a method of suspending the cable, reducing cable stretch.
Orderable
25366
Replacement Desiccant Tube for Pressure Transducers
The transducer's cable incorporates a vent tube that terminates inside of the 25366 desiccant tube. The 25366 is offered as a common accessory for customers who want a spare desiccant tube. The 25366 desiccant has a cobalt-free indicator that is orange and turns green when saturated. Please note: Prior to August 2019, the desiccant used in 25366 had a desiccant indicator that contained cobalt and would change color from blue to pink when saturated.
Orderable
A200
Sensor to PC Interface
The A200 interfaces a CS455 with a PC, allowing sensor settings to be changed via our Device Configuration Utility (DevConfig).
Orderable
Replacement Parts
(2)
25366
Replacement Desiccant Tube for Pressure Transducers
The 25366 may be purchased to replace a damaged desiccant tube. The CS455 is shipped with this small desiccant tube attached to it. The transducer's cable includes a vent tube that terminates inside of the 25366. The desiccant tube prevents water vapor from entering the inner cavity of the transducer. The 25366 desiccant has a cobalt-free indicator that is orange and turns green when saturated. Please note: Prior to August 2019, the desiccant used in 25366 had a desiccant indicator that contained cobalt and would change color from blue to pink when saturated.
Orderable
29137
3 oz Bottle of Replacement Desiccant
The 29137 is replacement desiccant for this transducer's desiccant tube. It provides enough desiccant to fill the tube approximately 2.5 times. The 29137 desiccant has a cobalt-free indicator that is orange and turns green when saturated. Please note: Prior to August 2019, the desiccant used in 29137 had a desiccant indicator that contained cobalt and would change color from blue to pink when saturated.
Orderable
Services
(2)25425
Calibration with Data for the CS450, CS451, CS455, or CS456
The 25425 requires an RMA (Return Material Authorization) from Campbell Scientific. When it is ordered, we will calibrate the CS455 to meet original specifications. Before and after calibration sheets are supplied with the pressure transducer.
Orderable27442
CS45X Recabling Service
Customers can get their transducer recabled but they must get an RMA (Return Material Authorization) and return the transducer to Campbell Scientific. The 27442 is a kit used by Campbell Scientific's Repair Department to recable the transducer. Please note that, the total cost for recabling the transducer is the price of the 27442 kit, plus labor charges, plus the per foot price of the cable.
Orderable
Compatibility
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Desiccated Case
The CS455 can be used with the A150. The A150 is a small, self-contained junction box that allows the CS455 to be connected to a continuation cable, a prewired-enclosure connector, or a CWS900-series wireless-sensor connector. Connection to a CWS900-series interface allows the CS455 to be part of a wireless sensor network.
Compatible Products
(15)
Basic Datalogger
Basic Datalogger
RetiredNotes—
Basic Datalogger
Basic Datalogger
RetiredNotes—
CR10
Measurement and Control System
RetiredNotes—
CR200X
Datalogger
RetiredNotes—
CR206X
Datalogger with 900 MHz Spread-Spectrum Radio
RetiredNotes—
CR211X
Datalogger with 922 MHz Spread-Spectrum Radio
End of lifeNotes—
CR216X
Datalogger with 2.4 GHz Spread-Spectrum Radio
RetiredNotes—
CR295X
Datalogger for GOES Satellite Communication
RetiredNotes—
CR800
Measurement and Control Datalogger
RetiredNotes—
CR850
Measurement and Control Datalogger
RetiredNotes—
CR1000
Measurement and Control Datalogger
RetiredNotes—
CR3000
Measurement and Control Datalogger
RetiredNotes—
CR5000
Measurement and Control Datalogger
RetiredNotes—
Datalogger for Measurement and Control
Datalogger for Measurement and Control
RetiredNotes—
Micrologger for Data Acquisition
Micrologger for Data Acquisition
RetiredNotes—
Related Resources
Documents
Press Releases
Product Life Events
- Available for Order
- February 11, 2009
- Retired
- January 31, 2014
- Free Support Until
- December 31, 2023
- Repair Available Until
- December 31, 2023
- End of Life
- December 31, 2028
- Calibration Available Until
- December 31, 2028