CS470
CS470
RetiredCompact Bubble Water Level Sensor, Standard Accuracy
No longer available to order
This product is retained for service, documentation, and compatibility information.
- Model:
- CS470
- Item Number:
- 25498
- Warranty:
- 2 years
Overview
The CS470 is a compact bubbler that generally measures ground or surface water level, but can also measure any liquid level. This bubbler has an accuracy of ±0.02 ft. A Campbell Scientific data logger controls the CS470 pump and calculates the measurements. The bubbler typically communicates with the data logger via the SDI-12 protocol. Many of our data loggers support SDI-12.
Key Advantages
Drift-free measurements and offset compensation
Technical Description
The CS470 contains a piston pump that compresses air. The compressed air flows through a measuring tube into the water being measured. The pressure created in the measuring tube is directly proportional to the water column above a bubble chamber. The CS470 measures both barometric pressure and bubble pressure, one after the other. The height of the water above the bubble chamber is then calculated by taking the difference between the barometric and bubble pressure measurements.
To use the CS470, the acquisition system must include the measuring tube, a bubble chamber, power supply, data logger, and data-logger-connection cable. Campbell Scientific offers the measuring tube, bubble chamber, and cable as Common Accessories. (See the Ordering Info on the web page.) The CS470, data logger, and power supply must be housed in a desiccated environment, typically a Campbell Scientific enclosure. Hardware for mounting the CS470 to an enclosure backplate is shipped with the sensor.
The CS470 can communicate via SDI-12, 4 - 20 mA, or RS-485 (SDI-12 protocol via a physical RS-485 interface). SDI-12 is the preferred protocol when using Campbell Scientific data loggers. Many of our data loggers support SDI-12.
Benefits
- Ideal for areas where submersed sensors can be damaged due to corrosion, contamination, flood-related debris, lightning, or vandalism
- Compatible with most Campbell Scientific data loggers
- Easy to maintain
- Robust pump design provides reliable operation
- Consistent accuracy ensured by drift-free measurements and offset compensation using relative measurement
- Purge function clears the measuring tube and the bubble chamber of contamination
- Does not use pressurized nitrogen tank—requiring less frequent attendance
- Existing tubes can be used
Specifications
- Accuracy
- ±0.61 cm
(±0.02 ft)
- Resolution
- 0.003 ft /0.014 psi
- Power Requirements
- 10 to 30 Vdc
- Measurement Time
- 1 min
- Outputs
- SDI-12 (version 1.3) 1200 bps, 4-20 mA, RS-484 (SDI-12 Protocol via RS-485 interface)
- Measurement Range
- 0 to 15.2 m
(0 to 50 ft)
- Operating Temperature Range
- -20° to +60°C
- Storage Temperature Range
- -40° to +85°C
- Relative Humidity Range
- 10% to 95% RH
(non-condensing)
- Measurement/Communication Current (Typical)
- 320 mAh/day
(1-minute query interval)
25 mAh/day(15-minute query interval)
- Maximum Measuring Tube Length
- 100.6 m
(330 ft)
- Electronics Box Dimensions
- 16.5 x 20.5 x 11.5 cm
(6.5 x 8.1 x 4.5 in.)
- Weight
- 1.5 kg
(3.3 lb)
Common Accessories
(2)
CABLE4CBL
4-Conductor 22 AWG Cable with Drain
The CABLE4CBL-L is used to connect the CS470 to a datalogger. This 22-AWG, four-conductor cable has a Santoprene jacket and an aluminum Mylar shield."
Orderable
25503
Polyethylene Tubing, 3/8 OD x 1/8 ID
The 25503 is polyethylene tubing with an 1/8" inner diameter and a 3/8" outer diameter. The tubing is submerged in the liquid. Specify length, in feet, when ordering.
Orderable
Replacement Parts
(2)
6044
Grommet for #6 or #8 Screw
These grommets are commonly used with the 505 screws to secure our equipment to the backplates of our enclosures.
Orderable
505
Screw #6-32 x .375 Pan Phillips
These screws, along with the 6044 grommets, are commonly used together to secure our equipment to the backplates of our enclosures.
Orderable
Ships With
(4)
505
Screw #6-32 x .375 Pan Phillips
OrderableQty 2
6044
Grommet for #6 or #8 Screw
OrderableQty 21113
Flat-Bladed Screwdriver, 3.0 mm Blade x 60 mm Shaft
- Installation Kit from original manufacturer
Compatibility
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Compatible Products
(15)
Basic Datalogger
Basic Datalogger
RetiredNotes—
Basic Datalogger
Basic Datalogger
RetiredNotes—
CR10
Measurement and Control System
RetiredNotes—
CR200X
Datalogger
RetiredNotes—
CR206X
Datalogger with 900 MHz Spread-Spectrum Radio
RetiredNotes—
CR211X
Datalogger with 922 MHz Spread-Spectrum Radio
End of lifeNotes—
CR216X
Datalogger with 2.4 GHz Spread-Spectrum Radio
RetiredNotes—
CR295X
Datalogger for GOES Satellite Communication
RetiredNotes—
CR800
Measurement and Control Datalogger
RetiredNotes—
CR850
Measurement and Control Datalogger
RetiredNotes—
CR1000
Measurement and Control Datalogger
RetiredNotes—
CR3000
Measurement and Control Datalogger
RetiredNotes—
CR5000
Measurement and Control Datalogger
RetiredNotes—
Datalogger for Measurement and Control
Datalogger for Measurement and Control
RetiredNotes—
Micrologger for Data Acquisition
Micrologger for Data Acquisition
RetiredNotes—
Related Resources
Product Life Events
- Available for Order
- March 12, 2009
- Retired
- December 16, 2016
- Free Support Until
- December 31, 2025
- End of Life
- December 31, 2025
- Calibration Available Until
- December 31, 2025
- Repair Available Until
- December 31, 2025