CR295X

Datalogger for GOES Satellite Communication
multi image upload

CR295X

Retired

Datalogger for GOES Satellite Communication

No longer available to order

This product is retained for service, documentation, and compatibility information.

Replaced by

  • CR300

    Measurement and Control Datalogger

  • CR310

    Measurement and Control Datalogger

Model:
CR295X
Item Number:
21946
Warranty:
3 years

Overview

The CR295X is a small, low-cost data logger that reads input from one or two sensors, then transmits the data using the GOES satellite transmitter. Multiple CR295Xs can be configured as a network, or units can be deployed individually. CRBasic, its full programming language, supports simple or complex programming and many onboard data reduction processes. It supports stand-alone operation in harsh, remote environments.

Key Advantages

Lowest-Cost Data Logger for Use With Satellite
Good for SDI-12 measurements

Technical Description

The CR295X includes an additional RS-232 serial port that allows communications with the TX320, TX312, or SAT HDR GOES satellite transmitter. It has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.

The CR295X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples. (Refer to the Compatibility information on the web page for compatible sensors, peripherals, and software.) Recalibration services are not offered for the CR295X dataloggers.

Benefits

  • Small, low-cost data logger designed for use with GOES satellite transmitters
  • When combined with the TX320 GOES satellite transmitter, the CR295X can be used in extremely remote locations.
  • Ideal applications include wind energy, rural water, water level/flow, aquaculture, water quality
  • Gas Discharge Tube (GDT) protected inputs
  • Optimal for measuring one or two simple sensors
  • Makes SDI-12, single-ended analog, pulse, switch closure, and bridge measurements
  • Battery-backed clock that ensures accurate time is maintained while data logger is disconnected from battery power
  • Program with LoggerNet, PC400, or Short Cut to fit your setup
  • PakBus, Modbus, and SDI-12 protocols supported

Specifications

-NOTE-
Note: Additional specifications are listed in the CR200X-Series Specifications Sheet.
Maximum Scan Rate
1 Hz
Analog Channels
The single-ended analog inputs can also be used as control ports.
5 single-ended (no differential)

individually configured

Pulse Count Channels
2
Switched Excitation Channels
2 voltage
Digital Ports
Certain digital ports can be used to count switch closures.
2 I/O
Communication Ports
2 RS-232
Switched Battery Port
1
Input Voltage Range
0 to 2500 mV
Analog Voltage Accuracy
±(0.25% of reading + (1.2 mV)x(offset))

at -40° to +50°C

Analog Voltage Resolution
0.6 mV
A/D Bits
12
Operating Temperature
-40° to +50°C
Power Requirements
7 to 16 Vdc
Typical Current Drain
~0.2 mA

(quiescent)

~3 mA

(active)

Clock Accuracy
8.2 min./month

(@ -40° to +50°C)

1 min./month

(@ +25°C)

Protocols Supported
PakBus (leaf node only), SDI-12
Warranty
3 years
Dimensions
14.0 x 7.6 x 4.8 cm

(5.5 x 3.0 x 1.9 in.)

Weight
242 g

(8.5 oz)

Memory

Final Storage
512 kB of flash memory for approximately 125,000 data points
Operating System
106 kB of flash memory
Intermediate Storage
8 kB of SRAM for communication buffers, calculations, variables, etc.

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Communications

The CR295X is compatible with our TX320, TX312 (retired), and SAT HDR GOES (retired) satellite transmitters.

The CR295X can communicate with a PC via direct connect, NL201 Network Link Interface, NL240 Wi-Fi Network Link, MD485 multidrop modem, and digital cellular modems. Data can be viewed on an iOS device, an Android device, CD295 DataView II Display, or a user-supplied PDA. To use an iOS or Android device, go to the Apple Store or Google Play and download our LoggerLink Mobile Apps free of charge. User-supplied PDAs require either PConnect or PConnectCE software.

Measurement & Control Peripherals

Campbell Scientific’s SDM devices and multiplexers are not supported.

Power Supplies

Typical power supply is a BP12 12 Ahr or BP24 24 Ahr battery, CH100 or CH200 regulator, and an SP10 or SP20 solar panel. The CR295X includes a cable for connecting it with the satellite transmitter and power supply.

Enclosures

An ENC16/18 enclosure can house the CR295X logger, satellite transmitter, and power supply; smaller enclosures cannot house the power supply required for GOES communications. Hardware is included with the data logger for mounting to an enclosure backplate.

Sensors

The CR295X can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.

Compatible Products

(64)

Related Resources

Product Life Events

Available for Order
December 8, 2009
Calibration Available Until
April 11, 2018
Retired
April 11, 2018
Free Support Until
January 31, 2028
End of Life
January 31, 2028
Repair Available Until
January 31, 2028