CS451
CS451
OrderableStainless-Steel Pressure Transducer
Pricing
Request a quote Have pricing access? Sign in
Configuration
- Standard 0.1% Accuracy, 0-2.9 psig (20 kPa)CS451-10-SA-2-SNPart Number: 45036-10-SA-2-SN
- Standard 0.1% Accuracy, 0-7.25 psig (50 kPa)CS451-10-SA-7-SNPart Number: 45036-10-SA-7-SN
- Standard 0.1% Accuracy, 0-14.5 psig (100 kPa)CS451-10-SA-14-SNPart Number: 45036-10-SA-14-SN
- Standard 0.1% Accuracy, 0-29 psig (200 kPa)CS451-10-SA-29-SNPart Number: 45036-10-SA-29-SN
- Standard 0.1% Accuracy, 0-72.5 psig (500 kPa)CS451-10-SA-72-SNPart Number: 45036-10-SA-72-SN
- Standard 0.1% Accuracy, 0-145 psig (1000 kPa)CS451-10-SA-145-SNPart Number: 45036-10-SA-145-SN
- Higher 0.05% Accuracy, 0-7.25 psig (50 kPa)CS451-10-HA-7-SNPart Number: 45036-10-HA-7-SN
- Higher 0.05% Accuracy, 0-14.5 psig (100 kPa)CS451-10-HA-14-SNPart Number: 45036-10-HA-14-SN
- Higher 0.05% Accuracy, 0-29 psig (200 kPa)CS451-10-HA-29-SNPart Number: 45036-10-HA-29-SN
- Higher 0.05% Accuracy, 0-72.5 psig (500 kPa)CS451-10-HA-72-SNPart Number: 45036-10-HA-72-SN
Select a configuration to add to your quote
- Model:
- CS451
- Item Number:
- 45036
- Warranty:
- 1 year
Overview
The CS451 is a pressure transducer with a stainless-steel case. It is used for water-level measurements and can be submerged in most canals, wells, ponds, lakes, and streams. The CS451 outputs either a digital SDI-12 or RS-232 signal to indicate observed pressure and temperature. This output can be read by many of our data loggers.
The CS451 replaces the CS450 transducer. The new transducers have a smaller gap between the water ports and the diaphragm so that less air is trapped that the user must remove during deployment. Trapped air causes the transducer's readings to drift as the air slowly dissolves into the water.
Key Advantages
Ideal for long-term deployment in harsh conditions
Technical Description
The CS451 consists of a piezoresistive sensor and a temperature sensor housed in a 316L stainless-steel case. It has a rugged Hytrel cable that remains flexible, even under harsh environmental conditions. The cable incorporates a vent tube to compensate for atmospheric pressure fluctuations. The vent tube terminates inside a desiccant tube, which prevents water vapor from entering the inner cavity of the transducer. The sensor ships with a desiccant tube that can be replaced in the field.
The CS451 has several pressure range options and two accuracy options (see Ordering Info). The standard accuracy option provides ±0.1% FS TEB over the 0° to 60°C temperature range. The high accuracy option provides ±0.05% FS TEB over the 0° to 60°C temperature range and includes a calibration certificate. TEB is the combined errors due to nonlinearity, hysteresis, non-repeatability, and thermal effects over the compensated temperature range, per ISA S51.1. Please note that the high accuracy option is not available for the 0 to 2.9 psig range option.
Campbell Scientific offers the A151 Vented, Single Sensor Terminal Case that allows the CS451 to be connected to a prewired enclosure (see Ordering Information).
Benefits
- Quality construction to ensure product reliability
- Rugged stainless-steel case protecting the piezoresistive sensor
- Compatible with most Campbell Scientific data loggers
- Fully temperature-compensated
- Low-power sleep state between measurements to reduce power consumption
- Optional weighted nose cone to facilitate submersion
- Optional NPT nose cone to enable usage in closed-pipe applications
- Quick shipment after receipt of order (ARO)
Specifications
- Measurement Time
- < 1.5 s
- Output Options
- SDI-12 (version 1.3) 1200 bps; RS-232 9600 bps
- Water-Level Resolution
- 0.0035% FS
- Worst-Case Temperature Resolution
- 0.006°C
- Dry Storage Temperature Range
- -40° to +100°C
WARNING: Sensor could be damaged if encased in frozen ice. - Operating Temperature Range
- 0° to 60°C
WARNING: Sensor could be damaged if encased in frozen ice. - Temperature Accuracy
- ±0.2°C
- Overpressure
- 2 x pressure range
- Power Requirements
- 6 to 18 Vdc
- Cable Type
- Hytrel Jacket, five conductor, 26 AWG
- NPT Fitting
- 1/4-in. NPS
- Top Cone Material
- Delrin
- Body Material
- 316L stainless steel
- Element Material
- 316L stainless steel
- Distance
- 2.54 cm
(1 in.)
Distance from black line etched on housing to end of NPT fitting2.3 cm(0.9 in.)
Distance from black line etched on housing to end of standard nose cone9.9 cm(3.9 in.)
Distance from black line etched on housing to end of weighted nose cone - Ingress Protection
- Exceeds IP68
- Diameter
- 21.34 mm
(0.84 in.)
- Cable Outer Diameter
- 0.589 cm
(0.232 in.) nominal
0.599 cm(0.236 in.) maximum
- Length
- 213.36 mm
(6.875 in.)
- Cable Weight
- 0.0421 kg/m
(0.0283 lb/ft)
- Weight
- 0.17 kg
(0.37 lb) without cable
Air Gap
- Standard & Weighted Nose Cone
- 0.653 cm
(0.257 in.)
- NPT Fitting
- 2.72 cm
(1.07 in.)
Power Consumption
- Quiescent
- < 50 µA
- Measurement/Communication
- 8 mA
(1 s measurement)
- Maximum
- 40 mA
Measurement Ranges at Fresh Water Depths
- 0 to 2.0 m (6.7 ft)
- 0 to 2.9 psig
The high accuracy (±0.05% FS) option is not available for the 0 to 2.9 psig range option.0 to 20 kPa
The high accuracy (±0.05% FS) option is not available for the 0 to 2.9 psig range option. - 0 to 5.1 m (16.7 ft)
- 0 to 7.25 psig0 to 50 kPa
- 0 to 10.2 m (33.4 ft)
- 0 to 14.5 psig0 to 100 kPa
- 0 to 20.4 m (67 ft)
- 0 to 29 psig0 to 200 kPa
- 0 to 50.9 m (167 ft)
- 0 to 72.5 psig0 to 500 kPa
- 0 to 102 m (334.5 ft)
- 0 to 145 psig0 to 1000 kPa
Accuracy
- Standard Accuracy Option
- ±0.1% full-scale-range TEB
Total Error Band (TEB) includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range, per ISA S51.1. - High Accuracy Option
- ±0.05% full-scale-range TEB
The high accuracy (±0.05% full-scale range) option is not available for the 0 to 2.9 psig range option.
Total Error Band (TEB) includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range, per ISA S51.1.
Cable Length
- Standard Lengths
- 5, 10, 15, 25, 30, and 60 m (16.4, 32,8, 49.2, 82.0, 98.4, and 196.9 ft), as well as a user-defined length
- SDI-12
- ~457 m (1500 ft)
maximum, 1 sensor connected to a single port
60 m (200 ft)maximum, 10 sensors connected to a single port
- RS-232
- 60 m (200 ft)
maximum
Accessories
(8)A200
Sensor to PC Interface
Orderable25366
Replacement Desiccant Tube for Pressure Transducers
OrderableA151
Single Sensor Terminal Case, Vented with Desiccant
Orderable25431
Split Mesh Cable Grip, 0.180 to 0.250
Orderable31648
Heyco Cable Grip Liquid Tight
Orderable33815
SDI-12 Terminal Bus Kit
Orderable39642
SDI-12 DIN Rail Terminal Bus Kit without Mounting Bracket
OrderableA151
Single Sensor Terminal Case, Vented with Desiccant
Orderable
Common Accessories
(6)25431
Split Mesh Cable Grip, 0.180 to 0.250
The 25431 Split Mesh Cable Grip is recommended for use in wells to center the cable and to provide a method of suspending the cable, reducing cable stretch.
Orderable25366
Replacement Desiccant Tube for Pressure Transducers
The transducer's cable incorporates a vent tube that terminates inside of the 25366 desiccant tube. The 25366 is offered as a common accessory for customers who want a spare desiccant tube. The 25366 desiccant has a cobalt-free indicator that is orange and turns green when saturated. Please note: Prior to August 2019, the desiccant used in 25366 had a desiccant indicator that contained cobalt and would change color from blue to pink when saturated.
OrderableA200
Sensor to PC Interface
The A200 interfaces a CS451 with a PC, allowing sensor settings to be changed via our Device Configuration Utility (DevConfig).
OrderableA151
Single Sensor Terminal Case, Vented with Desiccant
The A151 is a vented junction box with terminal blocks to connect sensors to an M12 eight-pin connector. It has accessories to allow the use of various lengths of cable and termination options.
Orderable31648
Heyco Cable Grip Liquid Tight
The 31648 is a clamp with 1 in. NPT threads that allows the CS451 to be mated with a 1 in. PVC pipe for installations purposes. A 1 in. female adapter socket with FPT threads is needed between the 31648 and 1 in. PVC pipe. This adapter socket is typically available at stores that sell PVC pipe.
Orderable39642
SDI-12 DIN Rail Terminal Bus Kit without Mounting Bracket
The 39642 makes it easier for you to connect wires from multiple SDI-12 sensors into one set of terminals on a data logger. The 39642 uses six DIN-rail mountable (pn 27479), 6-wire terminal blocks. The 39642 is a jumper that electrically connects two terminal blocks together at a time (pn 32918). This setup allows up to 11 SDI-12 sensors to be connected to one set of terminals on a data logger.
Orderable
Other Accessories
(2)33815
SDI-12 Terminal Bus Kit
The 33815 makes it easier for you to connect wires from multiple SDI-12 sensors into one set of terminals on a data logger. The 33815 uses six DIN-rail mountable (pn 27479) 6-wire terminal blocks. The 33815 jumpers two connectors together at a time (pn 32918). This setup allows up to 11 SDI-12 sensors to be connected to one set of terminals on a data logger.
OrderableA151
Single Sensor Terminal Case, Vented with Desiccant
The A151 is a vented junction box with terminal blocks to connect sensors to the AQWire eight-pin connector. It has accessories to allow the use of various lengths of cable and termination options.
Orderable
Replacement Parts
(2)25366
Replacement Desiccant Tube for Pressure Transducers
The 25366 may be purchased to replace a damaged desiccant tube. The CS451 is shipped with this small desiccant tube attached to it. The transducer's cable includes a vent tube that terminates inside of the 25366. The desiccant tube prevents water vapor from entering the inner cavity of the transducer. The 25366 desiccant has a cobalt-free indicator that is orange and turns green when saturated. Please note: Prior to August 2019, the desiccant used in 25366 had a desiccant indicator that contained cobalt and would change color from blue to pink when saturated.
Orderable29137
3 oz Bottle of Replacement Desiccant
The 29137 is replacement desiccant for this transducer's desiccant tube. It provides enough desiccant to fill the tube approximately 2.5 times. The 29137 desiccant has a cobalt-free indicator that is orange and turns green when saturated. Please note: Prior to August 2019, the desiccant used in 29137 had a desiccant indicator that contained cobalt and would change color from blue to pink when saturated.
Orderable
Services
(2)25425
Calibration with Data for the CS450, CS451, CS455, or CS456
The 25425 requires an RMA (Return Material Authorization) from Campbell Scientific. When it is ordered, we will calibrate the transducer to meet original specifications. Before and after calibration sheets are supplied with the pressure transducer.
Orderable27442
CS45X Recabling Service
Customers can get their transducer recabled but they must get an RMA (Return Material Authorization) and return the transducer to Campbell Scientific. The 27442 is a kit used by Campbell Scientific's Repair Department to recable the transducer. Please note that, the total cost for recabling the transducer is the price of the 27442 kit, plus labor charges, plus the per foot price of the cable.
Orderable
Need Something Not Listed?
(45036)Don't see what you need from among these options? Download the complete configuration list below.
View all product configurationsShips With
(1)- Calibration Certificate
Related Resources
Case Studies

Australia: Sugarcane Soil Nutrient Monitoring
To monitor nutrient losses from sugarcane crop-soil systems; which contribute to the water quality of aquatic and marine ecosystems within the Great Barrier Reef catchment area
Silkwood, QLD, Australia
July 11, 2018
View
Pennsylvania: Flood Warning
Measuring flood conditions and communicating warnings via social media
Upper Providence Township, Montgomery County, Pennsylvania
August 30, 2016
View
United Kingdom: Pioneering Research in Carbon Sequestration
University-based ecology and hydrology research
United Kingdom
January 26, 2024
View
Documents
- Manual
CS451/CS456 Product Manual (online)
View Document - Compliance
CS451, CS456, and 29326-L EU Declaration of Conformity
View Document - Manual
CS451/CS456 Pressure Transducer
April 2026
View Document - Brochure
CS451 Stainless-Steel SDI-12/RS-232 Pressure Transducer
July 2026
View Document
Showing 4 of 5 results
See all DocumentsDownloads
Videos and Tutorials

SDI-12 Sensors | Transparent Mode
November 27, 2013 (7:06)
Communicating with an SDI-12 sensor
Watch
SDI-12 Sensors | Watch or Sniffer Mode
November 27, 2013 (3:20)
Watching communication between an SDI-12 sensor and a datalogger
Watch
Displaying and Customizing Units of Measurement in CampbellCloud
May 17, 2024 (3:38)
How to add units of measurement to the CampbellCloud Data Explorer display
Watch
When the Rains Come: Solutions for Flood Warning and Monitoring
July 3, 2024 (36:24)
Webinar showing how to monitor flood risk with the Aspen 10 and get that data to the cloud
Watch