CR216X
CR216X
RetiredDatalogger with 2.4 GHz Spread-Spectrum Radio
Overview
The CR216X is a small, low-cost data logger that includes an internal 2.4 GHz spread-spectrum radio for transmitting data to another CR216(X), an RF416 radio, or RF432 radios. The 2.4 GHz frequency can be used worldwide.
The CR216X provides stand-alone operation in harsh, remote environments. It reads input from one or two sensors, then transmits its data wirelessly via its internal radio. Multiple CR216Xs can be configured as a network, or units can be deployed individually.
Key Advantages
Built-in spread-spectrum radio
Technical Description
The CR216X can be used in a wireless sensor network. Wireless sensor networks are appealing because they are often more economical than trenching, laying conduit, and pulling wire. When used as a wireless sensor, the CR216X measures the sensors attached to it, then transmits its data wirelessly via its spread-spectrum radio to a master data logger. The master data logger must use the PakBus communication protocol (e.g., CR800,CR850, CR1000, CR3000). For more information on how to configure a PakBus system, please read our PakBus Networking Guide.
The CR216X has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.
The CR216X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples. (Refer to the Compatibility information on the web page for compatible sensors, peripherals, and software.) Recalibration services are not offered for the CR216X dataloggers.
Benefits
- Small, low-cost data logger with internal spread spectrum radio for wireless communications
- Integrated radio lets this data logger function like a wireless sensor in a network, transmitting to a master data logger
- Ideal applications include wind energy, rural water, water level/flow, aquaculture, water quality
- Gas Discharge Tube (GDT) protected inputs
- Optimal for measuring one or two simple sensors
- Makes SDI-12, single-ended analog, pulse, switch closure, and bridge measurements
- Battery-backed clock that ensures accurate time is maintained while data logger is disconnected from battery power
- Program with LoggerNet, PC400, or Short Cut to fit your setup
- PakBus, Modbus, and SDI-12 protocols supported
Specifications
- -NOTE-
- Note: Additional specifications are listed in the CR200X-Series Specifications Sheet.
- Internal Spread-Spectrum Radio Operating Frequency Range
- 2.450 to 2.482 GHz
- Transmitter Power Output
- 50 mW
- Maximum Scan Rate
- 1 Hz
- Analog Channels
- The single-ended analog inputs can also be used as control ports.5 single-ended (no differential)
individually configured
- Pulse Count Channels
- 2
- Switched Excitation Channels
- 2 voltage
- Digital Ports
- Certain digital ports can be used to count switch closures.2 I/O
- Communication Ports
- 1 RS-232
- Switched Battery Port
- 1
- Input Voltage Range
- 0 to 2500 mV
- Analog Voltage Accuracy
- ±(0.25% of reading + (1.2 mV)x(offset))
at -40° to +50°C
- Analog Voltage Resolution
- 0.6 mV
- A/D Bits
- 12
- Operating Temperature
- -40° to +50°C
- Power Requirements
- 7 to 16 Vdc
- Typical Current Drain
- ~0.2 mA
(quiescent)
~3 mA(active, no radio)
~36 mA(active, radio receive)
~75 mA(active, radio transmit)
- Clock Accuracy
- 8.2 min./month
(@ -40° to +50°C)
1 min./month(@ +25°C)
- Protocols Supported
- PakBus (leaf node only), SDI-12
- CE Compliance Standards to which Conformity Is Declared
- IEC61326:2002
- Warranty
- 3 years
- Dimensions
- 14.0 x 7.6 x 4.8 cm
(5.5 x 3.0 x 1.9 in.)
- Weight
- 271 g
(9.5 oz)
Memory
- Final Storage
- 512 kB of flash memory for approximately 125,000 data points
- Operating System
- 106 kB of flash memory
- Intermediate Storage
- 8 kB of SRAM for communication buffers, calculations, variables, etc.
Common Accessories
(11)
17394
Converter, USB to DB9 Pin Socket RS-232
One end of the 17394 cable attaches to a USB port on a computer, and the other end of the cable attaches to the data logger's RS-232 port.
Orderable
BP7
7 Ah 12 V Sealed Rechargeable Battery
This sealed rechargeable battery for the CR216X has a 7 A h rating. The BP7 does not fit in the ENC200.
Orderable
15988
Wall Charger
The 15988 recharges the BP7 12 V, 7 A h battery via ac power. Its cable terminates in pigtails for attachment to the data logger's terminal strip.
Orderable
16755
2.4 GHz 13 dBd Yagi Enclosed Antenna with Mounting Hardware
Several antennas are offered. The 16755 is a high-gain (13 dBd), directional (Yagi) antenna that has a narrow beam width, so precise aiming is mandatory. It is useful for longer distances, and when only communicating with one other station (due to narrow beam width). This antenna requires an antenna cable to connect it to the CR216X.
Orderable
16005
2.4 GHz 0 dBd Omnidirectional 1/2 Wave Whip Antenna
Several antennas are offered. The 16005 is a unity gain (0 dBd), 1/2 wave whip, omnidirectional antenna. Its articulating knuckle joint can be oriented vertically or at right angles. This antenna attaches directly to the CR216X; a cable is not required.
Orderable
30411
2.4 GHz 5.8 dBd Omnidirectional Fiberglass Antenna without Mounting Hardware
The 30411 is a higher gain (5.8 dBd) omnidirectional antenna. It is suitable for base station use where you need to communicate with multiple stations located in different directions. The antenna has a TYPE N female connector and requires an antenna cable to connect it to the CR216X. It does not include mounting hardware, and is typically mounted with the 13906 (see below).
Orderable
13906
Mount for Fiberglass Antenex Omnidirectional Antennas
The 13906 provides hardware for mounting the 30411 antenna (see above).
Orderable
COAXRPSMA
LMR195 Antenna Cable with Reverse Polarity SMA and Type N Pin (Male) Connector
Either this cable or the COAXNTN-L (see below) is required when using the 16755 or 30411 antenna. The COAXRPSMA-L is an LMR195 cable that terminates in a type N male connector on the "antenna end" and a Reverse Polarity SMA (RPSMA) connector on the "transceiver end." This cable is recommended for applications where the cable length is less than 10 feet.
Orderable
COAXNTN
RG8 Antenna Cable with 2 Type N Pin (Male) Connectors
Either this cable or the COAXRPSMA-L (see above) is required when using the 16755 or 30411 antenna. The COAXNTN-L is a low-loss RG8 coaxial cable that requires the 31314 surge protection kit to connect it to the CR216. The COAXNTN-L/31314 combination is recommended over the COAXRPSMA-L when the antenna cable will be longer than 10 ft (as measured between the CR216X and the antenna) or when the CR216X will be used in an environment susceptible to lightning or electrostatic buildup.
Orderable
31314
Surge Protection Kit, Type N to RPSMA, 700 to 2700 MHz
The 31314 is an RF surge protection kit with flange mounting bracket. It may be flange-mounted to an enclosure backplate or bulkhead-mounted through an enclosure wall. One side of the surge protector connects to a radio with an RPSMA antenna connection. The other side connects to an antenna/antenna coaxial cable with Type N connector.
Orderable
21212
Black Cold Shrink Tape
This 10 ft (3.1 m) roll of 1"-wide black self-vulcanizing tape can help protect the connection of outdoor antennas. After connecting the coaxial cable to the antenna, wrap the tape around the connectors that are exposed to the environment.
Orderable
Replacement Parts
(4)
6044
Grommet for #6 or #8 Screw
These grommets are commonly used with the 505 screws to secure our equipment to the backplates of our enclosures.
Orderable
10873
Serial Data Cable, 9-Pin Socket (Female) to 9-Pin Pin (Male)
The 10873 is a serial cable that is useful for connecting the RS-232 port of the data logger to the 9-pin RS-232 port of a computer. The cable is six feet long.
Orderable
505
Screw #6-32 x .375 Pan Phillips
These screws, along with the 6044 grommets, are commonly used together to secure our equipment to the backplates of our enclosures.
Orderable
38403
3 V Coin Cell Lithium Battery
The 38403 is a CR2032X 240 mAh coin cell battery that needs to be periodically replaced.
Orderable
Compatibility
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Communications
The CR216X can communicate with a PC via direct connect, NL201 Network Link Interface, NL240 Wi-Fi Network Link, MD485 multidrop modem, and digital cellular modems. Data can be viewed on an iOS device, an Android device, CD295 DataView II Display, or a user-supplied PDA. To use an iOS or Android device, go to the Apple Store or Google Play and download our LoggerLink Mobile Apps free of charge. User-supplied PDAs require either PConnect or PConnectCE software.
The CR216X's internal spread spectrum radio can transmit data to other CR216(X) loggers, RF416 radios, or RF430 radios. Certain CR216X settings must match the radio's settings for communications between the data logger and radio to be successful. The factory default settings of these devices might not match; therefore, they may need to be reconfigured before communications can take place.
If the CR216X is in the transparent mode, it can communicate with the retired CR215 loggers or RF415 radios.
Measurement & Control Peripherals
Campbell Scientific’s SDM devices and multiplexers are not supported.
Sensors
The CR216X can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. It cannot make differential measurements and is not compatible with the freezing-rain/ice, fuel moisture/temperature, geographic position, present weather, soil heat flux, soil matric water potential, and strain sensors listed on our price lists.
Enclosures
Applications with minimal power requirements can use the ENC200 enclosure to house the data logger and the #16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the #16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR216X-based systems.
Power Supplies
The CR216X uses an external power supply and has a built-in regulator. When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 A h or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.
Compatible Products
(64)
014A-L
3-Cup Anemometer
RetiredNotes—
034B-L
Wind Set
RetiredNotes—
083E-L
Temperature and Relative Humidity Sensor
End of lifeNotes—
092-L
Barometer
End of lifeNotes—
109
Temperature Probe
OrderableNotes—
109SS
Stainless-Steel Temperature Probe for Harsh Environments
OrderableNotes—
110PV-L
Surface-Mount Thermistor
RetiredNotes—
237-L
Leaf Wetness Sensor
RetiredNotes—
255-100
Analog Output Evaporation Gauge
OrderableNotes—
03002
Wind Sentry Set
OrderableNotes—
03101
Wind Sentry Anemometer
RetiredNotes—
05103
Wind Monitor
OrderableNotes—
05103-45-L
Wind Monitor, Alpine Version
RetiredNotes—
05106-L
Wind Monitor, Marine Version
RetiredNotes—
05305
RM Young Wind Monitor AQ
OrderableNotes—
27106T
Vertical Propeller Anemometer
OrderableNotes—
52202
Electrically Heated Rain and Snow Gage
OrderableNotes—
A100LK
Vector Anemometer
OrderableNotes—
CS11-L
AC Current Sensor
RetiredNotes—
CS100
Barometric Pressure Sensor
RetiredNotes—
CS106
Barometer
OrderableNotes—
CS215-L
Digital Air Temperature and Relative Humidity Sensor
RetiredNotes—
CS300-L
Pyranometer
RetiredNotes—
CS410-L
Shaft Encoder
End of lifeNotes—
CS451
Stainless-Steel Pressure Transducer
OrderableNotes—
CS456
Titanium Pressure Transducer
OrderableNotes—
CS460-L
Pressure Transducer
RetiredNotes—
CS470
Compact Bubble Water Level Sensor, Standard Accuracy
RetiredNotes—
CS471
Compact Bubble Water Level Sensor, High Accuracy
RetiredNotes—
CS475-L
Radar Water-Level Sensor, 65 ft Maximum Distance
RetiredNotes—
CS475A-L
Radar Water-Level Sensor
RetiredNotes—
CS511
Dissolved Oxygen Sensor
OrderableNotes—
CS625
Water Content Reflectometer for CR200(X)-Series and CR300-Series
RetiredNotes—
CS650
30 cm Soil Moisture and Temperature Sensor
OrderableNotes—
CS655
12 cm Soil Moisture and Temperature Sensor
OrderableNotes—
CS700
Rain Gage with 8 in. Orifice
OrderableNotes—
Datalogger Starter Software
Datalogger Starter Software
RetiredNotes—
ENVIROSCAN
Water-Content-Profile Probe with SDI-12 Interface
End of lifeNotes—
HC2S3-L
Temperature and Relative Humidity Probe
RetiredNotes—
HMP60
Air Temperature and Relative Humidity Sensor
OrderableNotes—
HMP155A
Air Temperature and Relative Humidity Sensor
OrderableNotes—
ICEFREE3A
Anemometer
RetiredNotes—
ICEFREE3V
Wind Vane Sensor
OrderableNotes—
LoggerNet
Data Logger Support Software
OrderableNotesVersion 2.1 or higher

LWS
Leaf-Wetness Sensor
OrderableNotes—
OBS-3+
Turbidity Sensor
RetiredNotes—
OBS300
Turbidity Sensor
RetiredNotes—
OBS500
Smart Turbidity Meter with Antifouling Features
RetiredNotes—
OBS501
Smart Turbidity Meter with Antifouling Features
OrderableNotes—
P2546A
Three-Cup Anemometer with MEASNET Calibration
RetiredNotes—
PC400
Datalogger Support Software
OrderableNotesVersion 1.0 or higher

PCONNECT
Palm Datalogger Software with Connector and Cable
End of lifeNotes—
PCONNECTCE
PocketPC Datalogger Software with Connector and Cable
End of lifeNotesVersion 2.0 or higher

SEN12512
EasyAG Water-Content Probe with SDI-12 Interface
RetiredNotes—
Short Cut
Program Generator for Windows (SCWin)
OrderableNotes—
SR50A-L
Sonic Distance Sensor
RetiredNotes—
TB4
Rain Gage with 8 in. Orifice
OrderableNotes—
TB4MM
Metric Rain Gage with 8 in. Orifice
OrderableNotes—
TE525
Rain Gage with 6 in. Orifice
OrderableNotes—
TE525MM
Metric Rain Gage with 9.6 in. Orifice
OrderableNotes—
TE525WS
Rain Gage with 8 in. Orifice
OrderableNotes—
VISUALWEATHER - Retired
Weather Station Software
End of lifeNotesVersion 2 or higher

WINDSONIC4
2-D Sonic Wind Sensor with SDI-12 Output
OrderableNotes—
WXT520
Weather Sensor
RetiredNotes—
Incompatible Products
(9)
107
Temperature Probe
OrderableNotes—
108
Temperature Probe
OrderableNotes—
43347
RTD Temperature Probe
OrderableNotes—
CS547A
Water Conductivity and Temperature Probe
OrderableNotes—
CS616
30 cm Water Content Reflectometer
OrderableNotes—
CSAT3
3-D Sonic Anemometer
OrderableNotes—
CSIM11
pH Sensor
OrderableNotes—
CSIM11-ORP
ORP Probe
OrderableNotes—
WINDSONIC1
2-D Sonic Wind Sensor with RS-232 Output
OrderableNotes—
Related Resources
Documents
- Manual
PakBus Networking Guide
October 2008
View Document - Technical Paper
RF401-to-CR206 Communications: Quick Reference Guide
November 2009
View Document - Technical Paper
Line of Sight Obstruction
October 2016
View Document - Technical Paper
The Link Budget and Fade Margin
September 2016
View Document
Showing 4 of 11 results
See all DocumentsDownloads
Videos and Tutorials

EC100 Module | Updating the OS
October 30, 2012 (5:06)
Updating the operating system for the electronics module
Watch
LoggerLink Software | An Introduction
January 29, 2013 (12:11)
A mobile app for iOS and Android
Watch
LoggerNet Software | Network Planner
April 16, 2013 (4:05)
Designing a PakBus™ network using the Network Planner tool in LoggerNet
Watch
SDI-12 Sensors | Transparent Mode
November 27, 2013 (7:06)
Communicating with an SDI-12 sensor
Watch
Showing 4 of 19 results
See all Videos and TutorialsProduct Life Events
- Available for Order
- December 8, 2009
- Calibration Available Until
- April 11, 2018
- Retired
- April 11, 2018
- Free Support Until
- January 31, 2028
- End of Life
- January 31, 2028
- Repair Available Until
- January 31, 2028