LLAC4

4-Channel Low-Level AC-Conversion Module
LLAC4

LLAC4

Orderable

4-Channel Low-Level AC-Conversion Module

Pricing

Request a quote Have pricing access? Sign in

Model:
LLAC4
Item Number:
16710
Warranty:
1 year

Overview

The LLAC4 is a small peripheral that you can use to increase the number of low-level ac signals that your data logger can monitor. The LLAC4 is often used to measure up to four anemometers, and it is especially useful for wind profiling applications.

Key Advantages

Expands Capacity
Increases number of signals data logger can monitor

Technical Description

The LLAC4 enables four data logger control ports to emulate pulse-counting channels by converting the low-level ac signals to logic levels read by the control ports. To use the LLAC4, the data logger control ports must accept high frequency pulses. The LLAC4 typically measures anemometers but can measure other sensors that output pulse counting signals. 

Minimum AC Input Voltage versus Output Square Wave Frequency

Input Sine Wave
(mV RMS)
Output Range (Hz)
20 1.0 to 20
200 0.5 to 200
2000 0.3 to 10,000
5000 0.3 to 20,000

Benefits

  • Ideal for applications that require high numbers of pulse channels, but fewer control ports, such as in wind prospecting

Specifications

Function
Increases the number of low-level ac signals that a data logger can monitor.
Operational Temperature
-40° to +85°C
Number of Channels
4
Power
0.1 mA

(@ 12 Vdc)

Input Hysteresis
16 mV

(@ 1 Hz)

AC Coupling Removal of DC Offset
≤ ±0.5 V
Maximum AC Input Voltage
±20 V
Cable Length
0.6 m

(2 ft)

Dimensions
5.4 x 8.0 x 2.5 cm

(2.1 x 3.1 x 1.0 in.) without base mounting flanges

5.4 x 11.2 x 2.5 cm

(2.1 x 4.5 x 1.0 in.) with base mounting flanges

Weight
92 g

(3.2 oz)

Compatibility

Data Logger Considerations

The LLAC4 works only with data loggers whose control ports can accept high frequency pulses. The CR23X has four control ports that can be used (5, 6, 7, and 8); the CR200X-series control ports are compatible but are limited to inputs of 1 kHz.

Sensors

The LLAC4 typically measures anemometers. Compatible anemometers include the Wind Monitors, 03002 Wind Sentry Set, and 03101 Wind Sentry Anemometer. (The 014A Anemometer and 034B Windset are not compatible.) The LLAC4 can also measure other sensors that output pulse counting signals.

Related Resources