Prewired Enclosures / PWENC12/14
PWENC12/14
 
PWENC12/14 Pre-Wired Weather- Resistant 12 x 14 inch Enclosure
 
PWENC12/14 Options - show details
-C Connectors per ENC

Allowed values: 1-8 ea, increments of 1 ea

After the -C, enter the number of connectors you need. The PWENC12/14 can have up to eight connectors.
Communication Ports - show details
-NP -NP No 9-Pin Ports
Choose this option if you do not want any 9-pin ports nor an Ethernet port on the outside of your enclosure.
-1P -1P One 9-Pin Port
Choose this option if you want one 9-pin port for connecting communication equipment to the outside of the enclosure. It can be configured as a CS I/O port or RS-232 port. The port will be on the bottom right of the connector panel.
-2P -2P Two 9-Pin Ports
With this option, you get a CS I/O port and an RS-232 port on the outside of the enclosure. The ports will be on the bottom right of the connector panel.
-EP -EP Ethernet Port
This option allows you to connect an Ethernet cable to the enclosure. The Ethernet port will be on the bottom right of the connector panel.
Conduit Option - show details
-NC -NC No Conduit
Choose the -NC option if you do not want to route any of your cables through a conduit.
-SC -SC 1 Conduit
The -SC option provides one 1.5-in diameter conduit on bottom left of connector panel. Multiple cables can be routed through this conduit. The 7363 enclosure supply kit contains a plug that can reduce the conduit's internal diameter to 0.5" and putty for sealing the conduit.
Cable Entry Seal Options - show details
-NE -NE No Cable Entry Seal
Choose the -NE option if you do not want to route any of your cables through a cable-entry seal.
-SE -SE Sm Cable Entry Seal
This option orders one small cable-entry seal that fits a cable with a 0.118" to 0.275" (3 to 7 mm) diameter. The cable entry seal will be on the top left of the connector panel.
-ME -ME Med Cable Entry Seal
This option orders one medium cable entry seal that fits a cable with a 0.231" to 0.394" (5.8 to 10 mm) diameter. The cable entry seal will be on the top left of the connector panel.
Enclosure Mounts - show details
-NM -NM No Enclosure Mounting
With this option, the enclosure is shipped without brackets. Customers who will bolt their enclosure to a flat surface should choose the -NM option. The no bracket option might also be appropriate for applications in which the enclosure will be set on a table.
-MM -MM Tripod Mast Mounting
Order the "-MM" option if you want to mount your enclosure to the mast of one of our tripods or to a user-supplied pole with a 1.25" to 2.1" OD. A three-piece, stainless-steel bracket attaches to the top of the enclosure and an identical three-piece, stainless-steel bracket attaches to the bottom of the enclosure. Each bracket is attached to the mast or pole via a 2" u-bolt.
-LM -LM CM1xx Leg Mounting
The "-LM" option allows the enclosure to be attached to the leg base of a CM106, CM110, CM115, or CM120 tripod. This option includes a metal flange, two stainless-steel brackets, and a 2.5" u-bolt. The brackets attach to the right and left side of the enclosure, and the flange attaches to the tripod near the mast. The flange fits into a notch in one of the brackets, and the other bracket connects to a tripod leg via the u-bolt.
-TM -TM Tower Mounting
Order the "-TM" option if you want to mount your enclosure to a UT10, UT20, or UT30 tower. This mounting bracket option uses the same 3-piece, stainless-steel brackets as the "-MM" option, except the pieces are rearranged so that the flanges are on the side of the bracket instead of in the middle. Four 1.5" u-bolts attach the brackets to the tower legs.

Please note that enclosures with the "-TM" option are shipped configured for the UT10 tower. UT20 and UT30 customers will need to: (1) remove the bolts attaching the bracket to the enclosure, (2) slide out the flange sections so that the distance between the center of each flange is 17", and (3) reattach the bracket to the enclosure using the original bolts.
-PM -PM Pole Mounting, 4-10in
Choose the "-PM" option to mount the enclosure on a pole with a 4" to 10" OD. This option includes two stainless-steel brackets and two metal bands. One bracket is attached to the top of the enclosure and the other bracket is attached to the bottom of the enclosure. The metal bands are then routed through the brackets and wrapped around the pole. Screw clamps at the end of each band are used to tighten the bands around the pole.
-EM -EM ET Pole Mounting, 3in
Choose the "-EM" option to mount the enclosure on a pole with a 3" OD. This option uses strut clamps and a hangar bracket.

Add to your Quote List


Product Details
Typically Ships Within 14 - 21 Days
Restockable No
Warranty 1 year
Compliance

The "Typically Ships Within" value is an estimate of the number of calendar days within which this product is ready to ship from Campbell Scientific. Orders with more than 10 built-to-order products will likely increase the time needed to prepare the order for shipping.

To estimate how long it will take to receive an order that contains multiple products, combine the longest Ships Within value with the transit time of the shipping method you select.

Some specialized products have long Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.

Ships With
(1) 31136 8 GB USB Flash Drive with Campbell Scientific Logo
(1) 7363 Enclosure Supply Kit, Standard Size

Common Accessories

PROGRAM
 
The prewired enclosure includes a simple Short Cut program that measures the sensors and stores the hourly data. If you require a more complex program that, for example, compares values, controls devices, emails data, or initiates call-outs, order this PROGRAM. Your rate will be calculated based on the complexity of the program needed and the time Campbell Scientific needs to develop it.
CS210
 
The CS210 Enclosure Humidity Sensor contains an Elan HM2000-series precision bulk polymer relative humidity sensor. It senses relative humidity levels inside the environmental enclosure for the purpose of scheduling desiccant exchange. The desiccant should be exchanged when the sensor indicates an RH level of 35 percent or more inside the enclosure.
6714
 
The 6714 includes twenty 4-unit Silica Gel Desiccant Bags.
31551
 
The 31551 is a kit to allow stacking of components inside Campbell Scientific enclosures. The kit includes two leg brackets. It is used to raise a datalogger up and off the backplate so that wiring is easier or so that components can be stacked.
31143
 
The 31143 is a hinged stack bracket that is designed to fit a CR1000 datalogger, CR6 datalogger, or multiplexter on either the top or underneath. The hinge enables access to the equipment underneath without disconnecting any wires (assuming that the wires are long enough).
10614
 
This splice kit is used when you need to extend the cables outside of the enclosure.
31312
 
Commonly used with RF407-series or RF451 radio devices, the 31312 is an RF surge protection kit that is installed by Campbell Scientific, bulkhead-mounted through the enclosure wall. One side of the surge protector connects to a radio with an RPSMA antenna connection. The other side connects to an antenna or antenna coaxial cable with a Type N connector.
31315
 
Commonly used with cellular devices, the 31315 is an RF surge protection kit that is installed by Campbell Scientific, bulkhead-mounted through the enclosure wall. One side of the surge protector connects to a radio with an SMA antenna connection. The other side connects to an antenna/antenna coaxial cable with Type N connector.
31318
 
For use with third-party radios such as the FGR-11RC or FGR-115RE. The 31318 is an RF surge protection kit that is installed by Campbell Scientific, bulkhead-mounted through the enclosure wall. One side of the surge protector connects to a radio with a Type N antenna connection. The other side connects to an antenna/antenna coaxial cable with Type N connector.
31321
 
For use with HUGHES9502 and other third-party radios such as the FGR2-PE or XLR Pro. The 31321 is an RF surge protection kit that is installed by Campbell Scientific, bulkhead-mounted through the enclosure wall. One side of the surge protector connects to a radio with a TNC antenna connection. The other side connects to an antenna/antenna coaxial cable with Type N connector.
31324
 
For use with GPS antennas for TX320, AL200, COM9522B, or similar products. The 31324 is a GPS RF surge protection kit that is installed by Campbell Scientific, bulkhead-mounted through the enclosure wall. One side of the surge protector connects to a GPS receiver with an SMA antenna connection. The other side connects to the GPS antenna/antenna coaxial cable with Type N connector. The surge protector passes up to ±6 Vdc, commonly needed for active GPS antenna applications.
31327
 
For use with the TX320. The 31327 is an RF surge protection kit that is installed by Campbell Scientific, bulkhead-mounted through the enclosure wall. One side of the surge protector connects to a radio with a Type N antenna connection. The other side connects to an antenna/antenna coaxial cable with Type N connector.
31330
 
For use with the ST-21 or RF320-series. The 31330 is an RF surge protection kit that is installed by Campbell Scientific, bulkhead-mounted through the enclosure wall. One side of the surge protector connects to a radio with a BNC antenna connection. The other side connects to an antenna/antenna coaxial cable with Type N connector.
27814
 
Specify this to have Campbell Scientific install a CD100 in the enclosure door. The CD100 allows users to enter data and view both real-time and historical data, without opening the enclosure. Users can customize menus and displays, simplifying routine operations. The CD100 is typically used with the CR800 and CR1000.
18132
 
Specify this to have Campbell Scientific install a CD295 Data View II Display in the enclosure door. The CD295 allows users to view real-time data without opening the enclosure. It is used with our CR200(X), CR800, CR1000, and CR3000.
18166
 
Specify #18166 to have Campbell Scientific install an enclosure door switch indicator. This small accessory monitors when the door of the enclosure is open.

Other Accessories

COMCBL1-L
 
COMCBL1-L 9-Pin Male Weatherproof Cable w/Pigtails
 
This weatherproof cable is terminated with a D-sub 9 pin male (DE-9M) connector on one end and pigtail on the other. A typical use is to connect a sensor or peripheral with a DE-9F connection to a COM/C-pair on the CR800, CR1000, or CR3000.
Cable Length - show details
-L ft per cable

Allowed values: 1-80 ft, increments of 1 ft

When used with the CC640 camera, the recommended maximum length is 25 feet.
COMCBL2-L
 
COMCBL2-L 9-Pin Male to 9-Pin Female Weatherproof Cable
 
This weatherproof cable is terminated with a D-sub 9 pin male (DE-9M) connector on one end and D-sub 9 pin female (DE-9F) connector on the other. A typical use is to connect a sensor or peripheral with a DE-9M connection to the RS-232 port of a CR800, CR1000, or CR3000.
Cable Length - show details
-L ft per cable

Allowed values: 1-80 ft, increments of 1 ft

When used with the CC640 camera, the recommended maximum length is 25 feet.
 
The 19332 is a factory-installed 17 in. (43.2 cm) cable attached to a Type N connector on the inside of an enclosure, providing a Type N connector on the outside for attachment of a radio antenna. It is intended for enclosures that will house an RF320-series narrowband radio or TX320 HDR GOES satellite transmitter.
 
The 19333 is a factory-installed 17 in. (43.2 cm) cable attached to a Type N connector on the inside of an enclosure, providing a TNC connector on the outside for attachment of an antenna. It is intended for customers who will use a Raven100-series or Redwing100-series digital cellular modem with a 14454, 20679, or 18285 antenna (not used with the 14453 antenna).
 
The 19334 is a factory-installed 17 in. (43.2 cm) cable with an SMA connector on the inside of an enclosure and a Type N connector on the outside for attachment of an antenna. It is intended for enclosures that will house our RF450 radio, a RavenXT-series cellular modem, or a user-supplied Freewave radio.
19335
 
The 19335 is a factory-installed bulkhead-mounted coaxial cable. The associated enclosure on your order is properly cut to fit the Type N bulkhead connector, and the cable is installed prior to shipment. The cable has a Type N Female bulkhead connector on one end and an RPSMA plug (male) connector on the other. The cable is 17 in. (43.2 cm) of low-loss LMR-195. This cable assembly is generally used with an RF401-series radio, CR206X datalogger, AVW206 spectrum analyzer, or NL240 Wi-Fi interface inside the enclosure and a Type N Male-terminated radio-antenna cable outside the enclosure.
 
The 19336 is a factory-installed 17 in. (43.2 cm) cable attached to an SMA connector on the inside of an enclosure, providing an SMA connector on the outside for attachment of an antenna. It is intended for enclosures that will house the GPS device used with our satellite transmitter.

Replacement Parts

5449
 
The 5449 ground lug is attached to the enclosure. It may be purchased to replace a lost or damaged ground lug.
23
 
The pn 23 nut is available as a replacement item.
7363
 
The enclosure supply kit includes desiccant, a humidity indicator card, cable ties, wire tie tabs, putty for sealing the conduit, and screws and grommets for attaching peripherals to the enclosure backplate.
31136
 
The 31136 provides an alternate method for storing a pre-wired system's electronic files and is ideal for those users who do not have a CD/DVD drive but do have a USB port. The 31136 is shipped with each PWENC12/14 ordered. It can be purchased to replace a lost flash drive or for additional file storage.
 
The 22035 may be ordered to replace a lost or damaged cable.
 
The 25744 and 25746 are the two parts used to create the standard conduit for Campbell Scientific enclosures. If a portion of the conduit for an ENC or PWENC enclosure becomes lost, the 25744 and 25746 can be ordered as replacements.
 
The 25746 and 25744 are the two parts used to create the standard conduit for Campbell Scientific enclosures. If a portion of the conduit for an ENC or PWENC enclosure becomes lost, the 25746 and 25744 can be ordered as replacements.
560
 
The 560 screw is used to attach a backplate to the inside of an enclosure.
 
This 14 gauge ground wire connects the enclosure ground lug to the datalogger.