SDM-CD16ACA
SDM-CD16ACA
Orderable16-Channel AC/DC Relay Controller
Pricing
Request a quote Have pricing access? Sign in
- Model:
- SDM-CD16ACA
- Item Number:
- 40059
- Warranty:
- 1 year
Overview
With an SDM-CD16ACA, your Campbell Scientific data logger can automatically activate external ac or dc devices such as motors, pumps, heaters, valves, and fans. This ac/dc relay controller has 16 ports for connecting your ac or dc devices. Each port can be controlled automatically by the data logger’s program or controlled manually with an override toggle switch.
The SDM-CD16ACA is a RoHS-compliant version of the SDM-CD16AC.
Key Advantages
Use multiple modules for up to 256 control ports
Technical Description
The SDM-CD16ACA has a toggle switch that provides three positions: ON and OFF for manual override, and AUTO for data logger control.
- In the ON position, the common (COM) and normally open (NO) contacts are closed.
- In the OFF position, the normally open contact is open.
- In the AUTO position, the state of the relay is controlled by the SDM command issued through the data logger’s control ports or SDM terminal.
SDM Operation
The SDM-CD16ACA is a synchronously addressed data logger peripheral. Data logger control ports 1, 2, and 3 are used to address the SDM-CD16ACA, then clock out the desired state of each of the 16 control ports. Up to 15 SDM-CD16ACAs may be addressed, making it possible to control a maximum of 256 ports from the first three data logger control ports.
Benefits
- Allows the data logger to automatically turn devices on or off when a threshold (for example, temperature or water depth) has been reached
- Addresses up to 15 SDM-CD16ACAs, allowing up to 240 ports to be controlled by one data logger
- Includes LEDs that indicate when a port is active
- Provides a manual override for each port
- UL/CUL approved product; RoHS compliant
Specifications
- Function
- Allows a data logger to automatically activate external ac or dc devices such as motors, pumps, heaters, valves, and fans.
- Number of Channels
- 16
- Operating Temperature
- -40° to +55°C
- Humidity
- Non-condensing
- Contact Operation
- Single pole double throw
(break before make)
- Contact Material
- Gold-clad silver
- Wire Range
- 30 to 14 AWG
- Coil Voltage
- 11 to 18 Vdc
- Coil Resistance
- 360 Ω ±10%
- Expected Life (contact closures)
- Mechanical 107
- Actuation/Release Time
- ~4 ms
- Toggle Switch
- ON/OFF manual overrideAUTO for data logger control
- Operating Voltage
- 12 Vdc nominal
(11 to 18 Vdc)
- Standards
- Underwriters Laboratories (UL) listed product (E162021)
- Dimensions
- 24.6 x 5.1 x 8.6 cm
(9.7. x 2.0 x 3.4 in.)
- Weight
- 0.8 kg
(1.8 lb)
Individual Contact Ratings
- Normally Open Rating
- 5 A
(@ 30 Vdc)
5 A(@ 250 Vac, GP)
1 A(@ 240 Vac, Pilot Duty)
3 A(@ 120 Vac, Pilot Duty)
5 A(@ 240 Vac, Resistive)
- Normally Closed Rating
- 1 A
(@ 30 Vdc)
2 A(@ 277 Vac, GP)
3 A(@ 125 Vac, GP)
2 A(@ 120 Vac, Pilot Duty)
3 A(@ 240 Vac, Resistive)
Current Drain @ 12 Vdc
- Quiescent
- 6 mA
- Per Active LED
- 45 mA
(switch on or auto active)
Common Accessories
(3)CABLE5CBL
5-Conductor 22 AWG Cable with Drain
This cable connects the SDM-CD16ACA to the data logger. The CABLE5CBL is a 22 AWG, five conductor cable with a Santoprene jacket and an aluminum Mylar shield. A 1-ft cable length should be sufficient when both datalogger and SDM-CD16ACA are housed within an ENC12/14 enclosure; a 2-ft length may be required if the datalogger and SDM-CD16ACA are housed at opposite ends of an ENC16/18 enclosure.
CRBasic data loggers should use the SDMSpeed instruction if the cable length is longer than 20 ft. The maximum recommended length for the CR7 is 600 ft. For other Edlog dataloggers, the maximum recommended cable length is 20 ft.Orderable8125
Flat-Bladed Screwdriver, 2.5 mm Blade x 50 mm Shaft
If not ordering the data logger on the same order, you might need this small, flat-bladed screwdriver. The 8125 is extremely useful for opening the guillotine terminals on this module. The blade is 2.5 mm across and the untapered shaft length is 50 mm. The handle has an approximate length of 9 cm, and features a rotating end-cap that makes the screwdriver easy to rotate.
Orderable40192
Four-Year Extended Warranty for the SDM-CD16ACA
The 40192 extends the SDM-CD16ACA standard one-year warranty for an additional four years.
Orderable
Replacement Parts
(3)8480
5-Pin Screw Terminal Plug Connector with Threaded Flange
The 8480 Power Connector is for replacement only. This green power connector with screw terminals attaches to the top of the SDM-CD16ACA.
Orderable505
Screw #6-32 x .375 Pan Phillips
These screws, along with the 6044 grommets, are commonly used together to secure our equipment to the backplates of our enclosures.
Orderable6044
Grommet for #6 or #8 Screw
These grommets are commonly used with the 505 screws to secure our equipment to the backplates of our enclosures.
Orderable
Compatibility
Data Logger Considerations
Up to 15 SDMs can be connected to our data loggers. To communicate with connected SDM devices, the CR3000 and CR5000 use the SDM-C1, SDM-C2, and SDM-C3 ports. The other data loggers use ports labeled C1, C2, and C3. The 21X also requires channel 1H.
Programming
The SDMCD16AC Instruction controls SDM-CD16ACA operation in CRBasic. Edlog Instruction 29 controls SDM-CD16ACA operation in the CR7, and Edlog Instruction 104 controls SDM-CD16ACA operation in the CR10(X), CR23X, and 21X data loggers.
Power Considerations
The data logger's rechargeable power supply, connected to our newer 1.2 A wall charger, is sufficient for powering the SDM-CD16ACA. The SDM-CD16ACA's LEDs consume 45 mA each when active. If all 16 LEDs are active at once, a current drain of over 720 mA should be expected. If more than one SDM-CD16ACA will be used, a deep-discharge external battery may be necessary. This external battery should share a common grounding point with the data logger's ground.
Campbell Scientific does not recommended using the data logger’s alkaline batteries to power the SDM-CD16ACA for long-term applications.
Enclosure Considerations
The SDM-CD16ACA requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. Grommets and screws are provided to attach the flanges/bracket to the backplate of our enclosures.
Compatible Products
(10)CR6
High-Capacity Data Acquisition System
OrderableNotes—ENC10/12
Weather-Resistant Enclosure, 10 x 12 inches
OrderableNotes—ENC10/12R
Raised Lid Enclosure, 10 x 12 inches
OrderableNotes—ENC12/14
Weather-Resistant Enclosure, 12 x 14 inches
OrderableNotes—ENC14/16
Weather-Resistant Enclosure, 14 x 16 inches
OrderableNotes—ENC16/18
Weather-Resistant Enclosure, 16 x 18 inches
OrderableNotes—ENC24/30
Painted Steel Enclosure, 24 x 30 inches
OrderableNotes—ENC24/30S
Stainless-Steel Enclosure, 24 x 30 inches
OrderableNotes—Granite 10
Measurement and Control Data Acquisition System
OrderableNotes—Granite 9
High-Capacity, High-Speed Data Acquisition System
OrderableNotes—
Incompatible Products
(2)Related Resources
Documents
- Compliance
SDM-CD16AC and SDM-CD16ACA UL Canada Certificate of Compliance
January 2022
View Document - Compliance
SDM-CD16AC and SDM-CD16ACA UL US Certificate of Compliance
January 2022
View Document - Compliance
SDM-CD16ACA UK Declaration of Conformity
April 2022
View Document - Brochure
SDM-CD16ACA 16-Channel AC/DC Relay Controller
June 2026
View Document
Showing 4 of 6 results
See all Documents