ENC10/12
ENC10/12
OrderableWeather-Resistant Enclosure, 10 x 12 inches
Pricing
Request a quote Have pricing access? Sign in
Configuration
- 3 Entry Seals for Cables, Tripod Mast Mounting45360-3ES-MM-NA-NA
- 2 Conduits for Cables, No Enclosure Mounting45360-DC-NM-NA-NA
- No Conduit/Entry Seal, Tripod Mast Mounting45360-NC-MM-NA-NA
- No Conduit/Entry Seal, 4-10 Inch Pole Mounting45360-NC-PM-NA-NA
- 1 Conduit for Cables, Tripod Mast Mounting45360-SC-MM-NA-NA
- 1 Conduit for Cables, No Enclosure Mounting45360-SC-NM-NA-NA
- 1 Conduit for Cables, 4-10 Inch Pole Mounting45360-SC-PM-NA-NA
- 1 Conduit for Cables, Tower Mounting45360-SC-TM-NA-NA
- No Conduit/Entry Seal, Tower Mounting45360-NC-TM-NA-NA
Select a configuration to add to your quote
- Model:
- ENC10/12
- Item Number:
- 45360
- Warranty:
- 1 year
Overview
The ENC10/12 is a weather-resistant enclosure that is 10 inches wide and 12 inches tall. This enclosure can house and protect a smaller data logger, a power supply, and a small peripheral. Or it can house a peripheral that needs to be housed in an enclosure separate from the data logger.
Please note that a grounding wire is not included with the enclosure.
Key Advantages
Campbell components mount easily and securely
Technical Description
The ENC10/12's backplate is prepunched with half-inch-on-center holes suitable for attaching a data logger, power supply, and a communications or measurement and control peripheral.
The ENC10/12 is shipped with the 7363 enclosure supply kit that consists of desiccant, a humidity indicator card, cable ties, wire tie tabs, putty, grommets, screws, and PVC coupling. Additionally, Campbell Scientific offers a CS210 Enclosure Humidity Sensor for monitoring relative humidity inside of the enclosure. (See Ordering Info on the web page.)
Benefits
- Weather resistant to protect instruments
- Backplate designed so that Campbell Scientific components mount easily and securely
- White, UV-stabilized enclosure reflects solar radiation—reducing temperature gradients inside the enclosure without requiring a separate radiation shield
Specifications
- Color
- White
(Reflects solar radiation, reducing temperature gradients inside the enclosure without using a separate radiation shield.)
- Construction
- Fiberglass-reinforced polyester enclosure with door gasket, external grounding lug, stainless-steel hinge, and lockable hasps
- Enclosure Classification
- NEMA 4X
(before being modified for cable entry)
- Number of Cable-Entry Seals
- 1 medium, 2 small
- Dimensions
- 30.5 x 25.4 x 11.4 cm
(12 x 10 x 4.5 in.) internal
34.06 x 29.03 x 13.23 cm(13.41 x 11.43 x 5.21 in.) external
- Weight
- 4.1 kg
(9.0 lb)
Common Accessories
(4)10525
Desiccant and Document Holder for Enclosures
The 10525 is attached to the inside of the lid of the enclosure with adhesive Velcro strips (supplied). This desiccant holder accommodates two packages of our 4-unit desiccant."
Orderable6714
Four-Unit Desiccant Bags (quantity of 20)
The 6714 includes twenty 4-unit Silica Gel Desiccant Bags.
Orderable42815
Four-Unit Desiccant Bags (quantity of 10)
The 42815 includes 10 large, four-unit desiccant bags, used to absorb humidity within enclosures. Multiple packs are recommended for customers who need to desiccate multiple enclosures or systems.
OrderableCS211
Smart Enclosure Sensor
The CS211 is a low-power, smart sensor designed to monitor temperature and humidity levels inside enclosures. The sensor features an optical door switch to detect door openings and closings, and a multifunctional button that recognizes short, long, and double presses for user-defined actions. Additionally, the CS211 includes an LED indicator to signal enclosure wetness and when desiccant needs to be replaced.
Orderable
Replacement Parts
(14)28878
Replacement Enclosure Humidity Indicator Card
The 28878 is a replacement humidity indicator card. It provides a visual reference of humidity level inside the enclosure. Colored circles change color from blue to pink to indicate humidity levels of 30%, 40%, and 50% relative humidity. Double sticky tape on the back of the card allows it to be easily secured to an enclosure lid.
Orderable6316
Universal Backplate for ENC10/12
The 6316 provides a universal backplate for retrofitting older 10" x 12" enclosures. The anodized aluminum backplate is completely pre-punched with a matrix of half-inch-on-center holes. The 6316 replaced the now-retired 5947 Half Universal Backplate, which contained press-in hardware for the CR10 and 21X (upper half) and a grid of one-inch-on-center holes (lower half).
Orderable
Another backplate used in the ENC10/12 is also retired; the 5622 backplate had a special hole configuration that supported the AM32 multiplexer (the AM32 was a much larger predecessor of the AM16/32B).6832
Enclosure Filter with 60 Micron Pore Size
One 6832 filter may be installed in one of the small compression fittings (cable entry seals) in the ENC10/12 to allow air pressure to equalize between the inside and outside of the enclosure. As such, the filter is used only when the cable entry seals option is selected for the enclosure (item 6447). The filter is typically used when a barometric pressure sensor (or, in some cases, the cable termination of a vented submersible pressure transducer) will be located inside the enclosure. The filter has a 60 micron pore size.
Orderable18955
ENC10/12 Tripod Leg Mounting Kit
The 18955 provides the same bracket as "-LM" mounting option. This bracket may be ordered as a replacement part, if the bracket gets damaged, or if another option was originally chosen. The 18955 allows the enclosure to be attached to the leg base of a CM110, CM115, or CM120 lightweight tripod.
Orderable795
Stainless-Steel Nylock Nut 1/4-20
A couple of these nuts are attached to the enclosure bracket. The nut may be purchased to replace a lost or damaged nut.
Orderable5449
Enclosure Ground Lug
The 5449 ground lug is attached to the enclosure. It may be purchased to replace a lost or damaged ground lug.
Orderable23
Stainless-Steel Nut #10-32
The pn 23 nut is available as a replacement item.
Orderable7363
Enclosure Supply Kit, Standard Size
The enclosure supply kit includes desiccant, a humidity indicator card, cable ties, wire tie tabs, putty for sealing the conduit, and screws and grommets for attaching peripherals to the enclosure backplate.
Orderable25744
1-1/2 Panel Bushing Pin (Male)
The 25744 and 25746 are the two parts used to create the standard conduit for Campbell Scientific enclosures. If a portion of the conduit for an ENC or PWENC enclosure becomes lost, the 25744 and 25746 can be ordered as replacements.
Orderable25746
1-1/2 PVC Coupling PVC Female Adapter
The 25746 and 25744 are the two parts used to create the standard conduit for Campbell Scientific enclosures. If a portion of the conduit for an ENC or PWENC enclosure becomes lost, the 25746 and 25744 can be ordered as replacements.
Orderable560
Screw #10-32 x .312 Pan Phillips
The 560 screw is used to attach a backplate to the inside of an enclosure.
Orderable5725
14 AWG Enclosure Ground Wire, 24 in. long
This 14 gauge ground wire connects the enclosure ground lug to the datalogger.
Orderable3890
Silicone O-Ring
The 3890 is a silicone O-ring used. Customers will periodically need to replace worn-out O-rings.
Orderable6688
Plug for Cable Entry Connector
The 6688 is the plug that fits inside the 31363 Cable Entry Seal when there is not a cable running through it. The 6688 can be ordered to replace a lost plug.
Orderable
Need Something Not Listed?
(45360)Don't see what you need from among these options? Download the complete configuration list below.
View all product configurationsShips With
(1)Similar Products
(5)Compatibility
Peripherals
Retired peripherals that won’t fit in the same ENC10/12 enclosure as the data logger/power supply include the AVW4, AM416, COM100, CR10KD, DC1765, and RC35.
Compatible Products
(2)Incompatible Products
(1)Related Resources
Documents
- Technical Paper
Keeping Pests Away from Equipment (5-Y)
August 2020
View Document - Compliance
Weather-Resistant Enclosures EU Declaration of Conformity
June 2016
View Document - Manual
ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures
June 2021
View Document - Brochure
ENC10/12 Weather-Resistant Enclosure
March 2026
View Document