SR50ATH
SR50ATH
Limited availabilitySonic Distance Sensor with Heater and Temperature Sensor
Overview
Note: This product has limited availability. Please consider the SnowVue™10 Digital Snow-Depth Sensor for snow-depth measurements and the TempVue™20 Pt100 Digital Air Temperature Sensor or HygroVue™10 Digital Temperature and Relative Humidity Sensor with M12 Connector for air temperature measurements.
The SR50ATH is a sonic distance sensor with an integrated external temperature probe and heater. Sonic sensors determine distance by emitting an ultrasonic pulse and then measuring the elapsed time between the emission and return of the pulse. The temperature probe allows the SR50AT series to output temperature-corrected values (speed of sound varies with temperature). The integrated heater prevents ice and rime from coating the transducer.
Technical Description
The SR50ATH is an identical unit to the SR50A with the addition of an external temperature sensor and transducer heater. The temperature sensor requires a six-plate radiation shield. The addition of a heating element around the transducer prevents ice and rime from coating the transducer with minimal power requirements. The SR50ATH outputs a temperature-corrected distance reading, eliminating the need for further post-processing, as well as a separate temperature reading.
The SR50ATH was designed to meet the stringent requirements of measuring snow depths and uses a multiple echo processing algorithm to help ensure measurement reliability. The SR50ATH is compatible with all current Campbell Scientific data loggers, as well as many other data acquisition systems.
Benefits
- Integrated temperature probe for providing temperature correction of measurements
- Non-contact method for determining snow depth
- Wide operating temperature range
- Integrated transducer heater; rugged enough for rime and ice environments
- User-selectable options for output
- Uses a multiple echo processing algorithm to help ensure measurement reliability
- Compatible with most Campbell Scientific data loggers
Specifications
- Measurement Time
- < 1.0 s
- Output Options
- SDI-12 version 1.3, RS-232, RS-485
(output options selected by configuring internal jumpers)
- Baud Rates
- 1200 to 38400 bps
(RS-232, RS-485 modes)
- Power Requirements
- 9 to 18 Vdc
(typically powered by data logger’s 12 Vdc power supply)
- Quiescent Power Consumption in SDI-12 Mode
- < 1.0 mA
without heater
- Quiescent Power Consumption in RS-232/RS-485 Mode
- < 1.25 mA
(≤ 9600 bps) without heater
< 2.0 mA(> 9600 bps) without heater
- Active Power Consumption
- 250 mA typical
without heater
- Measurement Range
- 0.5 to 10 m
(1.6 to 32.8 ft)
- Beam Acceptance
- ~30°
- Resolution
- 0.25 mm
(0.01 in.)
- Accuracy
- ±1 cm (0.4 in.) or 0.4% of distance to target (whichever is greatest).
- Operating Temperature Range
- -45° to +50°C
- Temperature Accuracy
- ±0.2°C
(at 0° to 50°C)
±0.75°C(at -45° to 0°C)
- Compliance
- CE compliant
- Diameter
- 7.5 cm
(3 in.)
- Length
- 10.1 cm
(4.0 in.)
- Weight
- 375 g
(13.2 oz) without cable
- Cable Weight
- 250 g
(8.2 oz) for a 4.57-m (15-ft) cable
Heater
- Heater Resistance
- 75 ohm
- Nominal Operating Voltage
- 12 V
(ac or dc) Use a properly conditioned low-noise power source. A noisy power source will affect operation of the sensor.
- Maximum Rated Wattage
- 3 W
- Maximum Rated Voltage
- 15 V
(ac or dc)
- Maximum Operating Temperature
- 25°C
(Turn the heater power off at temperatures above 25°C. This prevents damage to the sensor and reduces power consumption.)
Maximum Cable Length
- -NOTE-
- Cable lengths greater than 60 m require a heavier gage wire if the power supply drops below 11 Vdc.
- SDI-12
- 60 m
(200 ft)
- RS-232
- 60 m
(200 ft) Baud rates ≤ 9600 bps
- RS-485
- 300 m
(984 ft)
Accessories
(12)SR50ATCBL
Replacement SR50AT Cable
Orderable19517
SR50A and SnowVue Mounting Kit
Orderable19484
SR50A and SnowVue Mounting Stem
Orderable17953
1- x 1-in. Nu-Rail Crossover Fitting
OrderableCM221
Right-Angle Mounting Kit
OrderableCM230
Adjustable Inclination Mounting Kit
OrderableCM230XL
Adjustable Angle Mounting Kit, Extended Length
OrderableRAD06
6-Plate Solar Radiation Shield
Orderable41303-5A
6-Plate Solar Radiation Shield
Orderable33815
SDI-12 Terminal Bus Kit
Orderable39133
DIN Rail Terminal Kit with 2 Terminals and 8 Wires
Orderable39642
SDI-12 DIN Rail Terminal Bus Kit without Mounting Bracket
Orderable
Common Accessories
(10)SR50ATCBL
Replacement SR50AT Cable
The SR50ATCBL cable may be ordered to add or replace a cable
Orderable19517
SR50A and SnowVue Mounting Kit
This mounting kit attaches directly to a CM206 crossarm or user-supplied pole with a 1-in. to 1.75-in. outside diameter.
Orderable19484
SR50A and SnowVue Mounting Stem
This mounting stem attaches to a sensor. The stem is then attached to the CM206 crossarm or a user-supplied pole via a CM220 mount, 17953 Nu-Rail fitting, or CM230 Adjustable Inclination Mount.
Orderable17953
1- x 1-in. Nu-Rail Crossover Fitting
The 17953 connects a vertical 1-inch pipe to a horizontal 1-inch pipe. The 17953 is typically used to attach a sensor with a 1-inch vertical pipe mount to a CM202, CM204, or CM206 crossarm. This usage provides functionality similar to the CM220 right-angle mounting bracket.
OrderableCM230
Adjustable Inclination Mounting Kit
The CM230 is an adjustable mount to point directional antennas or sensors at a specific target. The inclination can be adjusted to any angle from horizontal to vertical, supporting the use of upward-directed antennas or downward-directed infrared thermometers or snow-depth sensors.
OrderableCM221
Right-Angle Mounting Kit
The CM221 mounts a pipe or tube at 90° to another pipe or tube. It is typically used to attach a sensor with a vertical pipe (including most wind sensors) to a crossarm. The cast aluminum, right-angle mounting bracket has 3.8 cm (1.5 in.) U-bolts and hardware and will accommodate tubing with a 1- to 1.5-in. outer diameter.
OrderableCM230XL
Adjustable Angle Mounting Kit, Extended Length
The CM230XL is an adjustable mount to point directional antennas or sensors at a specific target. The inclination can be adjusted to any angle from horizontal to vertical, supporting the use of upward-directed antennas or downward-directed infrared thermometers or snow-depth sensors.
Orderable41303-5A
6-Plate Solar Radiation Shield
The 41303-5A is a naturally aspirated, 6-plate radiation shield. Its louvered construction allows air to pass freely through the shield, serving to keep the probe at or near ambient temperature. The shield's white color reflects solar radiation.
OrderableRAD06
6-Plate Solar Radiation Shield
When exposed to sunlight, the SR50ATH must be housed in a radiation shield. The RAD06 uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion. It also has lower self-heating in bright sunlight combined with higher temperatures (> 24°C (~75°F)) and low wind speeds (< 2m/s (~4.5 mph)), providing a better measurement.
Orderable39642
SDI-12 DIN Rail Terminal Bus Kit without Mounting Bracket
The 39642 makes it easier for you to connect wires from multiple SDI-12 sensors into one set of terminals on a data logger. The 39642 uses six DIN-rail mountable (pn 27479), 6-wire terminal blocks. The 39642 is a jumper that electrically connects two terminal blocks together at a time (pn 32918). This setup allows up to 11 SDI-12 sensors to be connected to one set of terminals on a data logger.
Orderable
Replacement Parts
(4)SR50ATCBL
Replacement SR50AT Cable
Note: This heater cable is only replaceable via a Returned Material Authorization (RMA).
Orderable42816
1/2-Unit Desiccant Bags (quantity of 10)
The 42816 desiccant is used to desiccate small subassemblies. For example, the KH20 Krypton Hygrometer and the base of the CR3000 Measurement and Control Datalogger each require two bags. Multi-packs are recommended for customers who need to desiccate multiple enclosures or systems.
Orderable42945
1 g Bag of Desiccant (quantity of 10)
The 42945 consists of 10 1-g bags of desiccant for drying the air in the area above an instrument. Six bags of the desiccant are used to dry the air in the area above the transducer. Purchase of additional bags is recommended to use as spares or to rotate bags with time.
Orderable32571
SR50AH or SR50ATH Replacement Transducer Maintenance Kit
The 32571 includes a transducer housing, desiccant, and a replacement O-ring. It is recommended that the transducer housing assembly be replaced every three years, or annually in high-humidity environments.
Orderable
Ships With
(2)- Test Report
SR50ATCBL
Replacement SR50AT Cable
Orderable
Compatibility
Data Logger Considerations
One single-ended channel per probe is required; an excitation channel can be shared by several probes.
Compatible Products
(3)CR310
Measurement and Control Datalogger
OrderableNotesSDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
CR6
High-Capacity Data Acquisition System
OrderableNotesSDI-12, RS-232, and RS-485
CR350
Measurement and Control Datalogger
OrderableNotesSDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface.
Related Resources
Documents
- Brochure
SR50ATH Sonic Ranging Sensor
March 2026
View Document - Manual
SR50A-Series Sonic Ranging Sensors
September 2021
View Document - Compliance
SR50AH, SR50ATH, SR50A, and SR50AT EU Declaration of Conformity
March 2022
View Document - Compliance
SR50AH, SR50ATH, SR50A, and SR50AT UK Declaration of Conformity
March 2022
View Document