RF310M

RF Modem
Automated
Automated

RF310M

Retired

RF Modem

No longer available to order

This product is retained for service, documentation, and compatibility information.

Replaced by

Item Number:
RF310M
Warranty:
1 year

Overview

The RF310M functions as the communication interface between a data logger and an RF310, RF312, or RF313 radio. Extended temperature testing is available for extreme environments.

 

Technical Description

The RF310M functions as the communication interface between a mixed-array data logger and an RF310, RF312, or RF313 radio. It's typically powered with the 5 Vdc provided by the data logger's CS I/O port. When the modem is at a non-data-logger repeater site, a PS100 Power Supply fitted with an A100 adapter is used to power the RF310M. Each RF310M contains dip switches that allow the user to address the modem with a number between 0 and 255.

Specifications

Power
35 mA at 5 Vdc

(from pin 1 on the data logger's CS I/O 9-pin connector)

Standard Operating Temperature Range
-25° to +50°C
Extended Operating Temperature Range
-55° to +70°C
Dimensions
16.3 x 8.4 x 2.5 cm

(6.4 x 3.3 x 1.0 in.) without mounts

17.3 x 11.9 x 2.5 cm

(6.8 x 4.7 x 1.0 in.) with mounts and connectors

Weight
227 g

(8 oz)

Similar Products

(1)

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Radios, Radio Modems, and Radio Base Stations

The RF310M is compatible with the RF310-series radios, the RF310B Base Station (retired), the RF500M Radio Modem, and the RF500B Base Station. If RF310M modems are used in a network containing RF500M modems or RF500B base stations then the RF310M modems must use the -TD PROM; the data loggers must also support PakBus (e.g., CR10X-PB, CR1000).

The RF310M is not compatible with our RF300-series radios, RF95A radio modems, RF315 radio modems, RF232(A) base stations, and PS232 base stations. Retired radios and radio modems (e.g., P50, RF100, RF95) are also not compatible with the RF310M.

Data Logger Considerations

Time division polling and PakBus communications can be used in the same network as long as all of the data loggers are PakBus versions.

Related Resources

Product Life Events

Available for Order
January 1, 1950
Retired
August 16, 2013
Free Support Until
December 31, 2020
End of Life
December 31, 2020
Calibration Available Until
December 31, 2020
Repair Available Until
December 31, 2020