CE4
CE4
Orderable4-Channel Current-Excitation Module
Overview
The CE4 is a current-excitation module that applies a constant current to the heating element of up to four 229 Heat Dissipation Water Matric Potential Sensors. A current-excitation module is required when you use 229 sensors to measure soil water matric potential.
Key Advantages
Provides excitation current for up to 4 model 229 soil-water sensors
Technical Description
A CE4 current excitation module can provide a constant current to the heating element of the 229. The CE4 sources current for up to four 229s. The module requires a 12 Vdc power source. The number of 229 sensors measured by one data logger can be increased by connecting a CE4 to one or more AM16/32-series multiplexers. Up to four multiplexers can be connected to the CE4.
Note: The CE4 module switches currents that are greater than 30 mA, which degrades the contact surfaces of the mechanical relays. Therefore, the multiplexer channels to which the CE4 have been connected may become unsuitable for other applications. (Refer to the multiplexer manual for more information.)
Benefits
- Provides excitation current for up to four 229 sensors
- Allows up to four AM16/32-series multiplexers to be connected, which significantly expands the system's capacity
- Compatible with most Campbell Scientific data loggers
Specifications
- Output
- 50 mA ±0.25 mA
(regulated)
- Output Channels
- 4
- Power
- 12 Vdc source required
- Active Current Drain
- 25 mA + (50 mA) x (number of 229s connected to the CE4)
- Dimensions
- 11.5 x 5.4 x 2.7 cm
(4.5 x 2.1 x 1.1 in.)
- Weight
- 131 g
(4.6 oz)
Replacement Parts
(2)505
Screw #6-32 x .375 Pan Phillips
These screws, along with the 6044 grommets, are commonly used together to secure our equipment to the backplates of our enclosures.
Orderable6044
Grommet for #6 or #8 Screw
These grommets are commonly used with the 505 screws to secure our equipment to the backplates of our enclosures.
Orderable
Compatibility
Data Logger Considerations
The CABLE3CBL can be used to connect the CE4 to the data logger (see Ordering Info).
Power Considerations
The CE4 requires 12 Vdc power. A data logger control port is typically used to activate the module. When the control signal is received, all 4 channels output a 50 mA source current to the connected loads (typically 229 probes). When the control signal is dropped to 0 Vdc, output from the module ceases.
When active, the current required from the 12 V supply is approximately the following:
25 mA + (50 mA)(the number of 229 sensors connected to the CE4 outputs).
Multiplexers
The CE4 can source current for four probes directly. In applications that require more sensors, the output(s) of the CE4 can be connected to as many as four AM16/32B multiplexers, greatly expanding system capacity.
When using multiplexers, the user should be aware that switching currents of greater than 30 mA will degrade the contact surfaces of the mechanical relays. This will adversely affect the suitability of these relays to multiplex low voltage signals. Although a relay used in this manner no longer qualifies for low voltage measurements, it continues to be useful for switching currents in excess of 30 mA. Therefore the user is advised to record which multiplexer channels are used to multiplex the 50 mA excitation for the 229-L probes in order to avoid using those channels for low voltage measurements in future applications.
Enclosure Considerations
The CE4 requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. The CE4's case has mounting flanges for attachment to the 1"-on-center hole grid of Campbell Scientific enclosures. Grommets and screws are provided to attach the flanges to the backplate of our enclosures.
Compatible Products
(7)ENC10/12
Weather-Resistant Enclosure, 10 x 12 inches
OrderableNotes—ENC10/12R
Raised Lid Enclosure, 10 x 12 inches
OrderableNotes—ENC12/14
Weather-Resistant Enclosure, 12 x 14 inches
OrderableNotes—ENC14/16
Weather-Resistant Enclosure, 14 x 16 inches
OrderableNotes—ENC16/18
Weather-Resistant Enclosure, 16 x 18 inches
OrderableNotes—CR6
High-Capacity Data Acquisition System
OrderableNotes—CR1000Xe
Measurement and Control Datalogger