CR3000
 
CR3000 Micrologger (R)
 
Temperature Ranges - show details
-ST -ST -25 to +50C
Every CR3000 is tested and guaranteed to perform within published specifications over the standard temperature range. Units are tested and shipped to the standard temperature range unless an extended range is specified. Any internal batteries are not tested or guaranteed across the entire standard temperature range.
-XT -XT -40 to +85C
When ordered, the CR3000 is tested and guaranteed to perform over the extended temperature range. Analog accuracies are derated approximately two times over the published specifications. The extended testing covers the -40° to +85°C range. Any internal batteries are not tested or guaranteed across the entire extended temperature range.
Warranty Lengths - show details
-SW -SW Standard 3yr Warranty
At the time of purchase, the CR3000 includes a standard warranty of 36 months. See our full warranty policy in the CR3000 manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our extended warranty adds 48 months to the standard 36-month warranty, bringing the total warranty period to 84 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
Base & Power Options - show details
-NB -NB Base with No Battery
Base without battery is for applications where user-supplied batteries are used.
-ALK -ALK Base w/Alkaline Batt
The alkaline base includes ten alkaline D cells. Operating temperature range is -25° to +50°C.
-RC -RC Rechargeable Base
The rechargeable base option provides two 6-V, 7-Ahr sealed rechargeable batteries that can be trickle-charged via vehicle power (requires DCDC18R), solar panels (typically SP10 or SP20), or ac power (requires 29796 transformer). Operating temperature range is -40° to +60°C.
Calibration Certificate - show details
-NC -NC No Calibration Cert
The CR3000 is shipped without a calibration certificate.
-CC -CC Calibration Cert
When this option is chosen, a two-page calibration certificate is shipped with the CR3000. If you are using the 21852 A2LA/NVLAP Calibration Service, you do not need to order this option because Simco will send you a calibration certificate (see below for a description of the 21852 service).

Add to your Quote List


Product Details
Typically Ships Within 14 - 21 Days
Restockable Yes
Warranty 3 years
Compliance CE Compliance Image RoHS Compliance Image

The "Typically Ships Within" value is an estimate of the number of calendar days within which this product is ready to ship from Campbell Scientific. Orders with more than 10 built-to-order products will likely increase the time needed to prepare the order for shipping.

To estimate how long it will take to receive an order that contains multiple products, combine the longest Ships Within value with the transit time of the shipping method you select.

Some specialized products have long Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.

Ships With
(1) 3315 Type T Thermocouple
(1) 8125 Flat-Bladed Screwdriver, 2.5 mm Blade x 50 mm Shaft
(1) 10873 Serial Data Cable, 9-Pin Female to 9-Pin Male

Common Accessories

DCDC18R
 
The DCDC18R Boost Regulator accepts an 11 to 16 Vdc input and boosts it to 18 Vdc, which allows automotive supply voltages to recharge the CR3000's sealed rechargeable battery.
18359
 
The CR3000's insulated aluminum thermocouple cover is intended to reduce thermal gradients across the analog inputs.
17394
 
The 17394 interface cable provides a USB connector on one end and a 9-pin male RS-232 connector on the other end. The USB connector attaches to the USB port on a PC, and the RS-232 connector attaches to the RS-232 port on the CR3000.
SC110
 
The SC110 consists of two cables. One end of both cables provides stripped, tinned leads for attachment to the datalogger control ports. On the other end, one of the cables is fitted with a 9-pin male connector, and the other cable is fitted with a 9-pin female connector. By having two cables, connection to either an RS-232 DCE or DTE device is supported depending on the cable used.
SC-CPI
 
SC-CPI Datalogger Serial to CPI Interface
 
The SC-CPI allows the CR1000 to communicate with a CDM.
Temperature Ranges - show details
-ST -ST -25 to +50C
Every SC-CPI is tested and guaranteed to perform within published specifications over the standard temperature range.Units are tested and shipped to standard operating range unless extended testing is specified.
-XT -XT -55 to +85C
Extended temperature testing over the -55° to +85°C range is also available. Individual units are subjected to performance tests at these extremes in a test chamber. Units that pass the tests are certified as extended temperature units.
Warranty Lengths - show details
-SW -SW Standard 1yr Warranty
At the time of purchase, the SC-CPI includes a standard warranty of 12 months. See our full warranty policy in the SC-CP manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our extended warranty adds 48 months to the standard 12 month warranty, bringing the total warranty period to 60 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
29796
 
29796 Power Supply 24Vdc 1.67A Output, 100-240Vac 1A Input, 5ft Cable
 
The 29796 converts 100 to 240 Vac to a regulated 24 Vdc. It comes standard with a USA/Canada plug, with an option to add a kit for international use. The cable has 5 ft length and terminates in pigtails with "+" and "-" labels.
Power Cable Options
-US -US US & Canada Plug
-IP -IP 7 International Plugs
SP10
 
SP10 10W Solar Panel, 20ft Cable
 
The SP10 recharges the sealed rechargeable batteries using solar power. It provides a 10 W maximum peak power, 9 W guaranteed minimum power, 0.59 A current at peak, and 16.8 V voltage at peak.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a pre-wired enclosure.
-C -C w/ ET/CS110 Connector
With the -C option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station. This is equivalent to the -LC version available for some sensors.
Mounting Options - show details
-SM -SM Std Mounting Kit
Standard mounting to allow solar panel to be mounted directly to the leg of a tower or crossarm.
-EM -EM Extended Mounting Kit
Extended Mounting Kit allows the solar panel to be mounted on a tower or crossarm that puts the panel approximately 25.4 cm (10 in.) from the mast. This reduces shadows on the solar panel from other components or guy wires, which negatively affects the performance of the solar panel. It does, however, increase the wind load on the system.
SP20
 
SP20 20W Solar Panel, 15ft Cable
 
The SP20 recharges the sealed rechargeable batteries using solar power. It provides a 20 W maximum peak power, 18 W guaranteed minimum peak power, 1.19 A current at peak, and 16.8 V voltage at peak.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a pre-wired enclosure.
Mounting Options - show details
-SM -SM Std Mounting Kit
Standard mounting to allow solar panel to be mounted directly to the leg of a tower or crossarm.
-EM -EM Extended Mounting Kit
Extended Mounting Kit allows the solar panel to be mounted on a tower or crossarm that puts the panel approximately 25.4 cm (10 in.) from the mast. This reduces shadows on the solar panel from other components or guy wires, which negatively affects the performance of the solar panel. It does, however, increase the wind load on the system.
22110
 
22110 Power Supply 24VdC 1.67A Output, 100-240Vac 1A Input for PW Systems
 
The 22110 is a 24 Vdc wall charger that recharges sealed rechargeable battery via ac power. One end of the 22110 connects to the wall socket; either a USA/Canada plug or an international plug is available. The other end has a connector that attaches to the pre-wired enclosure.
Power Cable Options
-US -US US & Canada Plug
-IP -IP 7 International Plugs
 
This service increases delivery time by approximately one week. The 21852 is offered for customers who require calibration validation from an accredited calibration laboratory. When the 21852 is ordered, Campbell Scientific calibrates the datalogger, and then sends the datalogger to Simco Electronics in Salt Lake City, Utah. After Simco receives the datalogger, they perform a calibration validation under the A2LA/NVLAP accreditation. Simco also provides a calibration certificate.

Other Accessories

 
The 18531 is offered for customers who want a paper CR3000 Operators Manual in a 3-ring binder.
27373
 
The 27373 facilitates connecting multiple wires into the same terminal, such as for SDI-12.

Replacement Parts

905
 
The 905 Single 0.5-Unit Desiccant Pack is used to desiccate the inside of the CR3000.
3768
 
This green, plug-in power connector is shipped attached to the face of the CR3000 when the low-profile base is ordered. The 3768 provides screw terminals for connecting the 12 V and GND wires of the power supply. Please note that the power connector for the rechargeable base is the 7843 (see below).
7843
 
This 2-pin, detachable, power supply connector (green) is supplied with the rechargeable base of the CR3000. The 7843 can be purchased to replace a lost or damaged connector.
18173
 
This green terminal strip provides connectors for the excitation and pulse channels. The 18173 may be purchased to have a spare terminal strip or as a replacement item if the strip has been lost or damaged.
18172
 
This green terminal strip provides connectors for the analog input channels labeled 8 through 14. The 18172 may be purchased to have a spare terminal strip or as a replacement item if the strip has been lost or damaged.
18171
 
This green terminal strip provides connectors for the analog input channels labeled 1 through 7. The 18171 may be purchased to have a spare terminal strip or as a replacement item if the strip has been lost or damaged.
18170
 
This green terminal strip provides the connectors for the control and power channels. The 18170 may be purchased to have a spare terminal strip or as a replacement item if the strip has been lost or damaged.
 
The 17315 may be purchased to replace a lost or damaged cover. It sits on the peripheral port to protect it.
13519
 
This 3.6 V lithium battery powers the clock and SRAM when the primary 12 Vdc power supply is not connected. The 13519 needs to be periodically replaced.
10645
 
The 10645 is the screw used in the ground lug.
 
The 18034 orders the two-page calibration certificate for your CR3000. If not specified, the CR3000 will be shipped without a calibration certificate.
8219
 
The 8219 provides one of the 6-Vdc, 7-Ahr sealed rechargeable batteries used in the rechargeable base. To supply 12 Vdc, two 8219 batteries must be wired in series. Customers can generally replace these batteries.
10873
 
The 10873 is a serial cable that is useful for connecting the RS-232 port of the datalogger to the 9-pin RS-232 port of a computer. The cable is six feet long.
3315
 
This type T, 5 in. thermocouple is attached to a differential channel on several of our datalogger wiring panels when the datalogger is shipped. A 3315 may be ordered to replace a thermocouple that has become lost or damaged.
8125
 
The 8125 is a small, flat-bladed screwdriver that is extremely useful for opening the guillotine terminals on our dataloggers and measurement control devices.

Services

 
Retesting is available only for individual units that have previously passed Extended Temperature Testing. Retesting also requires concurrent purchase of recalibration. An RMA (Returned Material Authorization) from Campbell Scientific is required.
18547
 
The 18547 requires an RMA (Returned Material Authorization) from Campbell Scientific. When ordered, the CR3000 is recalibrated to meet original specifications. Recalibration includes standard temperature testing (-25° to +50°C). Before and after calibration sheets are supplied with the datalogger. The calibration price assumes return of a fully functional datalogger; charges for all repairs will be added to the invoice.
 
The 18034 orders a two-page calibration certificate. If you are using the 21852 A2LA/NVLAP Calibration Service, you do not need to order this certificate because Simco will send you a calibration certificate.