CSAT3B
CSAT3B
Limited availability3-D Sonic Anemometer with Integrated Electronics
Pricing
Configuration
Sign in for option pricing- Sonic Carrying CaseCSAT3B-SC
- No Carrying CaseCSAT3B-NC
Select a configuration to add to your quote
- Model:
- CSAT3B
- Item Number:
- CSAT3B
- Warranty:
- 1 year
Overview
Campbell Scientific’s CSAT3B 3-D Sonic Anemometer is an update and replacement to the original CSAT3, and remains the 3-D sonic anemometer of choice for eddy-covariance measurements. It has an aerodynamic design, a 10 cm vertical measurement path, operates in a pulsed acoustic mode, and withstands exposure to harsh weather conditions. Three orthogonal wind components (ux, uy, uz) and the sonic temperature (Ts) are measured and output at a maximum rate of 100 Hz.
The most conspicuous innovation of the new design is the elimination of the electronics box. Instead, the electronics are packaged inside the mounting block of the CSAT3B head. This design feature makes installation easier and offers greater flexibility in instrument placement.
Measurements can be triggered from three sources:
- Data logger SDM command
- Data logger CPI command
- CSAT3B internal clock
The SDM and CPI protocols both support mechanisms for synchronizing multiple CSAT3Bs.
Key Advantages
Designed for flux and other turbulence research projects
Benefits
- New conformal coating helps protect sonic transducers in corrosive environments
- Integrated electronics that provide easy mounting of a single piece of hardware
- Integrated inclinometer
- High-precision measurements ideal for turbulence and eddy-covariance studies
- An improved design with a thin, aerodynamic support strut close to the ends of the sensor arms, creating greater rigidity and improved accuracy of sonic temperature
- Data logger sampling supported for any frequency between 1 and 100 Hz
- New CPI communications for more robust, higher bandwidth measurements
- Multiple communication options including SDM, CPI, USB, and RS-485
- Internal temperature and humidity measurements with easily replaced desiccant
- Version 5 algorithm for calculating data outputs; combines the signal sensitivity of version 3 with the rain performance of version 4
- Includes options to filter high frequencies for applications requiring analysis of non-aliased spectra
Specifications
- Sensor
- 3-dimensional sonic anemometer
- Measurement Description
- Highest-quality wind speed and direction
- Operating Temperature Range
- -40 to +50°C
(equivalent to 305 to 368 m s-1 in speed of sound)
- Outputs
- ux, uy, uz, Ts
(ux, uy, uz are wind components referenced to the anemometer axes; Ts is sonic temperature in degrees Celsius.)
- Signal Type/Output
- SDM, CPI, USB, RS-485
- Speed of Sound
- Determined from three acoustic paths.
(Corrected for crosswind effects.)
- Wind Direction Range
- 2.5 to 357.5° in CSAT3B coordinate system
(0 to 360° customized)
- Range
- ± 65 m s–1
(full-scale wind)
- Filter Bandwidths
- 5, 10, or 25 Hz
- Measurement Path Length
- 10.0 cm (3.9 in.) vertical; 5.8 cm (2.3 in.) horizontal
- Transducer Angle from Horizontal
- 60 degrees
- Ingress Protection
- IP67
- Transducer Diameter
- 0.64 cm
(0.25 in.)
- Transducer Mounting Arm Diameter
- 0.84 cm
(0.33 in.)
- Support Arm Diameter
- 1.59 cm
(0.63 in.)
- Anemometer Head Weight
- 1.45 kg
(3.2 lb)
- Anemometer Dimensions
- 60.64 x 12.2 x 43.0 cm
(23.87 x 4.8 x 16.9 in.)
Wind Accuracy
- -NOTE-
- Accuracy specifications assume the following:
-40° to +50°C operating rangeWind speeds < 30 m s-1Wind angles between ±170°
- Maximum Offset Error
- < ±8.0 cm s-1 (ux, uy), < ±4.0 cm s-1 (uz)
- Maximum Gain Error
- < ±2% of reading
(wind vector within ±5° of horizontal)
< ±3% of reading(wind vector within ±10° of horizontal)
< ±6% of reading(wind vector within ±20° of horizontal)
Measurement Resolution
- ux, uy
- 1 mm s-1 rms
- uz
- 0.5 mm s-1 rms
- Ts
- 0.002°C RMS
(at 25°C)
- Wind Direction
- < 0.058°
(ux = uy ≤ 1 m s-1)
Measurement Rates
- Data Logger Triggered
- 1 to 100 Hz
- Unprompted Output (to PC)
- 10, 20, 50, or 100 Hz
- Internal Self-Trigger Rate
- 100 Hz
Measurement Delay
- Data Logger Triggered (no filter)
- 1 trigger period
(1 scan interval)
- Unprompted Output (no filter)
- 10 ms
- Filtered Output (data-logger-prompted or unprompted to PC)
- 795 ms
(with 5 Hz bandwidth filter)
395 ms(with 10 Hz bandwidth filter)
155 ms(with 25 Hz bandwidth filter)
Internal Monitor Measurements
- Update Rate
- 2 Hz
- Inclinometer Accuracy
- ±1°
- Relative Humidity Accuracy
- ±3%
(over 10 to 90% range)
±7%(over 0 to 10% range)
±7%(over 90 to 100 % range)
- Board Temperature Accuracy
- ±2°C
SDM
- -NOTE-
- Used for data-logger-based data acquisition.
- Bit Period
- 10 µs to 1 ms
- Cable Length
- 7.6 m (25 ft) max
(@ 10 µs bit period)
76 m (250 ft) max(@ 1 ms bit period)
- Address Range
- 1 to 14
- Bus Clocks per Sample
- ~200
CPI
- -NOTE-
- Used for data-logger-based data acquisition.
- Baud Rate
- 50 kbps to 1 Mbps
- Cable Length
- 15 m (50 ft) max
(@ 1 Mbps)
122 m (400 ft) max(@ 250 kbps)
853 m (2800 ft) max(@ 50 kbps)
- Address Range
- 1 to 120
- Bus Clocks per Sample
- ~300
RS-485
- -NOTE-
- Used for configuration or PC-based data acquisition.
- Baud Rate
- 9.6 kbps to 115.2 kbps
- Cable Length
- 305 m (1000 ft) max
(@ 115.2 kbps)
610 m (2000 ft) max(@ 9.6 kbps)
- Bus Clocks per Sample
- ~500
(ASCII formatted)
USB
- -NOTE-
- Used for configuration or PC-based data acquisition.
- Connection Speed
- USB 2.0 full speed 12 Mbps
- Cable Length
- 5 m (16.4 ft) maximum
Power Requirements
- Voltage Supply
- 9.5 to 32 Vdc
- Current at 10 Hz Measurement Rate
- 110 mA
(@ 12 Vdc)
65 mA(@ 24 Vdc)
- Current at 100 Hz Measurement Rate
- 145 mA
(@ 12 Vdc)
80 mA(@ 24 Vdc)
Accessories
(15)CSAT3BCBL2
Power-Only Cable for CSAT3B
OrderableCSAT3BCBL3
CPI/RS-485 Cable for CSAT3B
OrderableCSAT3BCBL1
Power/SDM Cable for CSAT3B
Orderable4335
10 AWG Green Copper Stranded Wire
Orderable32473
Power Cable Compensation Plug for the CSAT3B
Orderable10080
Thermocouple Cover for CSAT3, CSAT3B, or IRGASON
Orderable31423
Fine-Wire Thermocouple Cover Backplate
OrderableFW05
Type E Fine-Wire Thermocouple with 0.0005 in. Diameter
OrderableFW/ENC
Fine-Wire Thermocouple Carrying Case (hold four thermocouples)
OrderableFWC
Connector Cable for Fine-Wire Thermocouples
OrderableHUB-SDM8
8-Channel Hub for SDM Peripherals and Power Connections
OrderableCABLE5CBL
5-Conductor 22 AWG Cable with Drain
OrderableHUB-CPI
8-Channel RJ45 Hub for CPI Peripherals
Orderable28899
CAT6 Ethernet Unshielded Cable with RJ45 Connectors, 2 ft
Orderable38476
16 GB microSD Flash aMLC Memory Card
Orderable
Related Resources
Case Studies
Documents
- Manual
CSAT3B Packing Information
January 2019
View Document - Compliance
CSAT3B EU Declaration of Conformity
March 2020
View Document - Compliance
CSAT3B FCC Supplier Declaration of Conformity and FCC Statement
March 2020
View Document - Brochure
CSAT3B 3-D Sonic Anemometer with Integrated Electronics
April 2026
View Document
Showing 4 of 9 results
See all DocumentsDownloads
- CSAT3B OSv3.02Login required
October 14, 2019
OS and FirmwareCurrent CSAT3B Operating System.
- CSAT3B Example Programsv1Login required
October 20, 2020
Software ApplicationsThree example programs. Simple SDM Program: SDM communications are used to collect data from a single CSAT3B. Simple CPI Program: CPI communications are used to collect data from a single CSAT3B. Advanced CPI Program: A single CSAT3B is properly configured and CPI communications are used to collect the data.
- CPI Calculatorv1.0Login required
July 6, 2016
Software ApplicationsThe CPI Calculator is a downloadable Microsoft Excel spreadsheet used to estimate the usage and capacity of a CPI network. The calculator provides an overview on CPI devices including the CDM-A108, CDM-A116, CDM-VW300, CDM-VW305, and the CSAT3B. The calculator can also estimate the measurement speed of the CDM-A108 and CDM-A116 based on the number of channels and measurement parameters. The CPI Calculator is an estimation tool and will help you better understand and design CPI networks by considering the following: What is the capability of each CDM or CPI device What is the CPI network capacity How much of the CPI capacity are the CDMs or CPI devices using