CSAT3B
CSAT3B
Limited availability3-D Sonic Anemometer with Integrated Electronics
Pricing
Request a quote Have pricing access? Sign in
Configuration
- Sonic Carrying CaseCSAT3B-SCPart Number: 42079
- No Carrying CaseCSAT3B-NCPart Number: 42078
Select a configuration to add to your quote
- Model:
- CSAT3B
- Item Number:
- CSAT3B
- Warranty:
- 1 year
Overview
Campbell Scientific’s CSAT3B 3-D Sonic Anemometer is an update and replacement to the original CSAT3, and remains the 3-D sonic anemometer of choice for eddy-covariance measurements. It has an aerodynamic design, a 10 cm vertical measurement path, operates in a pulsed acoustic mode, and withstands exposure to harsh weather conditions. Three orthogonal wind components (ux, uy, uz) and the sonic temperature (Ts) are measured and output at a maximum rate of 100 Hz.
The most conspicuous innovation of the new design is the elimination of the electronics box. Instead, the electronics are packaged inside the mounting block of the CSAT3B head. This design feature makes installation easier and offers greater flexibility in instrument placement.
Measurements can be triggered from three sources:
- Data logger SDM command
- Data logger CPI command
- CSAT3B internal clock
The SDM and CPI protocols both support mechanisms for synchronizing multiple CSAT3Bs.
Key Advantages
Designed for flux and other turbulence research projects
Benefits
- New conformal coating helps protect sonic transducers in corrosive environments
- Integrated electronics that provide easy mounting of a single piece of hardware
- Integrated inclinometer
- High-precision measurements ideal for turbulence and eddy-covariance studies
- An improved design with a thin, aerodynamic support strut close to the ends of the sensor arms, creating greater rigidity and improved accuracy of sonic temperature
- Data logger sampling supported for any frequency between 1 and 100 Hz
- New CPI communications for more robust, higher bandwidth measurements
- Multiple communication options including SDM, CPI, USB, and RS-485
- Internal temperature and humidity measurements with easily replaced desiccant
- Version 5 algorithm for calculating data outputs; combines the signal sensitivity of version 3 with the rain performance of version 4
- Includes options to filter high frequencies for applications requiring analysis of non-aliased spectra
Specifications
- Sensor
- 3-dimensional sonic anemometer
- Measurement Description
- Highest-quality wind speed and direction
- Operating Temperature Range
- -40 to +50°C
(equivalent to 305 to 368 m s-1 in speed of sound)
- Outputs
- ux, uy, uz, Ts
(ux, uy, uz are wind components referenced to the anemometer axes; Ts is sonic temperature in degrees Celsius.)
- Signal Type/Output
- SDM, CPI, USB, RS-485
- Speed of Sound
- Determined from three acoustic paths.
(Corrected for crosswind effects.)
- Wind Direction Range
- 2.5 to 357.5° in CSAT3B coordinate system
(0 to 360° customized)
- Range
- ± 65 m s–1
(full-scale wind)
- Filter Bandwidths
- 5, 10, or 25 Hz
- Measurement Path Length
- 10.0 cm (3.9 in.) vertical; 5.8 cm (2.3 in.) horizontal
- Transducer Angle from Horizontal
- 60 degrees
- Ingress Protection
- IP67
- Transducer Diameter
- 0.64 cm
(0.25 in.)
- Transducer Mounting Arm Diameter
- 0.84 cm
(0.33 in.)
- Support Arm Diameter
- 1.59 cm
(0.63 in.)
- Anemometer Head Weight
- 1.45 kg
(3.2 lb)
- Anemometer Dimensions
- 60.64 x 12.2 x 43.0 cm
(23.87 x 4.8 x 16.9 in.)
Wind Accuracy
- -NOTE-
- Accuracy specifications assume the following:
-40° to +50°C operating rangeWind speeds < 30 m s-1Wind angles between ±170°
- Maximum Offset Error
- < ±8.0 cm s-1 (ux, uy), < ±4.0 cm s-1 (uz)
- Maximum Gain Error
- < ±2% of reading
(wind vector within ±5° of horizontal)
< ±3% of reading(wind vector within ±10° of horizontal)
< ±6% of reading(wind vector within ±20° of horizontal)
Measurement Resolution
- ux, uy
- 1 mm s-1 rms
- uz
- 0.5 mm s-1 rms
- Ts
- 0.002°C RMS
(at 25°C)
- Wind Direction
- < 0.058°
(ux = uy ≤ 1 m s-1)
Measurement Rates
- Data Logger Triggered
- 1 to 100 Hz
- Unprompted Output (to PC)
- 10, 20, 50, or 100 Hz
- Internal Self-Trigger Rate
- 100 Hz
Measurement Delay
- Data Logger Triggered (no filter)
- 1 trigger period
(1 scan interval)
- Unprompted Output (no filter)
- 10 ms
- Filtered Output (data-logger-prompted or unprompted to PC)
- 795 ms
(with 5 Hz bandwidth filter)
395 ms(with 10 Hz bandwidth filter)
155 ms(with 25 Hz bandwidth filter)
Internal Monitor Measurements
- Update Rate
- 2 Hz
- Inclinometer Accuracy
- ±1°
- Relative Humidity Accuracy
- ±3%
(over 10 to 90% range)
±7%(over 0 to 10% range)
±7%(over 90 to 100 % range)
- Board Temperature Accuracy
- ±2°C
SDM
- -NOTE-
- Used for data-logger-based data acquisition.
- Bit Period
- 10 µs to 1 ms
- Cable Length
- 7.6 m (25 ft) max
(@ 10 µs bit period)
76 m (250 ft) max(@ 1 ms bit period)
- Address Range
- 1 to 14
- Bus Clocks per Sample
- ~200
CPI
- -NOTE-
- Used for data-logger-based data acquisition.
- Baud Rate
- 50 kbps to 1 Mbps
- Cable Length
- 15 m (50 ft) max
(@ 1 Mbps)
122 m (400 ft) max(@ 250 kbps)
853 m (2800 ft) max(@ 50 kbps)
- Address Range
- 1 to 120
- Bus Clocks per Sample
- ~300
RS-485
- -NOTE-
- Used for configuration or PC-based data acquisition.
- Baud Rate
- 9.6 kbps to 115.2 kbps
- Cable Length
- 305 m (1000 ft) max
(@ 115.2 kbps)
610 m (2000 ft) max(@ 9.6 kbps)
- Bus Clocks per Sample
- ~500
(ASCII formatted)
USB
- -NOTE-
- Used for configuration or PC-based data acquisition.
- Connection Speed
- USB 2.0 full speed 12 Mbps
- Cable Length
- 5 m (16.4 ft) maximum
Power Requirements
- Voltage Supply
- 9.5 to 32 Vdc
- Current at 10 Hz Measurement Rate
- 110 mA
(@ 12 Vdc)
65 mA(@ 24 Vdc)
- Current at 100 Hz Measurement Rate
- 145 mA
(@ 12 Vdc)
80 mA(@ 24 Vdc)
Accessories
(15)CSAT3BCBL2
Power-Only Cable for CSAT3B
OrderableCSAT3BCBL3
CPI/RS-485 Cable for CSAT3B
OrderableCSAT3BCBL1
Power/SDM Cable for CSAT3B
Orderable4335
10 AWG Green Copper Stranded Wire
Orderable32473
Power Cable Compensation Plug for the CSAT3B
Orderable10080
Thermocouple Cover for CSAT3, CSAT3B, or IRGASON
Orderable31423
Fine-Wire Thermocouple Cover Backplate
OrderableFW05
Type E Fine-Wire Thermocouple with 0.0005 in. Diameter
OrderableFW/ENC
Fine-Wire Thermocouple Carrying Case (hold four thermocouples)
OrderableFWC
Connector Cable for Fine-Wire Thermocouples
OrderableHUB-SDM8
8-Channel Hub for SDM Peripherals and Power Connections
OrderableCABLE5CBL
5-Conductor 22 AWG Cable with Drain
OrderableHUB-CPI
8-Channel RJ45 Hub for CPI Peripherals
Orderable28899
CAT6 Ethernet Unshielded Cable with RJ45 Connectors, 2 ft
Orderable38476
16 GB microSD Flash aMLC Memory Card
Orderable
Common Accessories
(13)CSAT3BCBL1
Power/SDM Cable for CSAT3B
The Power/SDM cable CSAT3BCBL1 is used to deliver power and SDM communications to a CSAT3B.
OrderableCSAT3BCBL2
Power-Only Cable for CSAT3B
The Power-Only cable CSAT3BCBL2 is used to deliver power to a CSAT3B that will use CPI, USB, or RS-485 communications instead of SDM communications.
OrderableCSAT3BCBL3
CPI/RS-485 Cable for CSAT3B
The CPI/RS-485 cable CSAT3BCBL3 is used to deliver CPI or CPI communications between a CSAT3B and a data logger, another CSAT3B, or a wiring hub.
Orderable4335
10 AWG Green Copper Stranded Wire
This 10-gauge copper grounding wire is used to properly ground the sonic anemometer.
Orderable32473
Power Cable Compensation Plug for the CSAT3B
The 32473 compensates for power droop on a long cable and/or when daisy-chaining multiple CSAT3B anemometers.
Campbell Scientific recommends the application of a 32473 plug when a user is using multiple CSAT3Bs or is using a single unit on a very long lead (for example, greater than 99.97 m [328 ft]). The plug requires the 30293 power/SDM cable splitter to connect to the CSAT3B and the power cable simultaneously.Orderable10080
Thermocouple Cover for CSAT3, CSAT3B, or IRGASON
The 10080 is a white thermocouple cover for the FW05, FW1, and FW3 connectors. This cover is placed over the Omega-brand thermocouple connectors and is used to mount the connectors to the side of the CSAT3 or IRGASON FWTC bracket. A CSAT3B or CSAT3A also requires the 31423 Fine-Wire Thermocouple Cover Backplate.
Orderable31423
Fine-Wire Thermocouple Cover Backplate
The 31423 is required to make the fine-wire thermocouple assembly compatible with the CSAT3B.
OrderableFW05
Type E Fine-Wire Thermocouple with 0.0005 in. Diameter
Measures atmospheric temperature gradients or fluctuations with research-grade accuracy.
OrderableFW/ENC
Fine-Wire Thermocouple Carrying Case (hold four thermocouples)
Protects thermocouples during shipping and transport.
OrderableFWC
Connector Cable for Fine-Wire Thermocouples
Connects a fine-wire thermocouple to a data logger.
OrderableCS106
Barometer
The CS106 measures barometric pressure for the range of 500 to 1100 hPa (mBar). This range equates to from below sea level (as in a mine) to over 15,000 feet above sea level.
OrderableHygroVue 10
Digital Temperature and Relative Humidity Sensor with M12 Connector
The HygroVUE™10 offers a combined temperature and relative humidity element in an advanced digital sensor that is ideal for weather networks. The electronics within the sensor provide accurate measurements, and the sensor is easy to use. The digital SDI-12 output allows a simple connection and measurement by many data logging systems. Another benefit is that this digital output avoids the extra errors associated with measuring analog sensors.
Orderable38476
16 GB microSD Flash aMLC Memory Card
The 38476 is a 16 GB microSD flash-memory card designed for use in harsh conditions often presented by environmental and industrial applications in which customers require higher reliability, endurance, and performance but also seek a cost-effective solution to meet budget-planning requirements.
Orderable
Other Accessories
(4)HUB-SDM8
8-Channel Hub for SDM Peripherals and Power Connections
The HUB-SDM8 is intended for customers who want to connect up to five external SDMs to the same data logger, as well as run multiple power connections using 16 AWG wire. The HUB-SDM8 comprises an environmental enclosure with eight compression fittings (two larger) and eight terminal strips.
OrderableCABLE5CBL
5-Conductor 22 AWG Cable with Drain
The CABLE5CBL is a 22 AWG five-conductor cable used to connect the Power/SDM connections from a HUB-SDM8 to the Power and SDM connections on a power source and data logger.
OrderableHUB-CPI
8-Channel RJ45 Hub for CPI Peripherals
The HUB-CPI allows eight CPI (CAN peripheral interface) devices to be connected together in parallel. Typically, this configuration includes one data logger and up to seven CDMs (Campbell distributed modules) or sensors that use CPI.
Orderable28899
CAT6 Ethernet Unshielded Cable with RJ45 Connectors, 2 ft
The 28899 is a 2 ft CAT6 Ethernet cable used to connect a HUB-CPI to a CPI socket on a data logger, or to connect one HUB-CPI to another HUB-CPI.
Orderable
Replacement Parts
(7)28902
Spare Sonic Wicks Kit
The Spare Sonic Wicks Kit includes three upper transducer wicks, three lower transducer wicks, and a wick-installation tool.
Orderable30749
CSAT3B(H) Replacement Desiccant
The 30749 is a small cylindrical canister of desiccant that is used in the CSAT3B to keep the internal electronics dry. The canister should be replaced as soon as the CSAT3B internal relative humidity exceeds 25%, or when the silica gel changes in color from blue to pink.
Orderable30748
CSAT3B(H) Replacement Bubble Level Kit
The 30748 contains a bubble level and three screws. It is used to replace the bubble level on a CSAT3B sonic anemometer.
Orderable30747
CSAT3B Replacement Carrying Case with Foam Insert
The 30747 is a large, rugged carrying case with foam to accommodate a CSAT3B sonic anemometer and its accessories. It is recommended for use when transporting or shipping the CSAT3B.
Orderable33435
CSAT3B Replacement Carrying Case without Foam
The 33435 is a large, rugged carrying case without foam to accommodate a CSAT3B sonic anemometer and its accessories. It is recommended for use when transporting or shipping the CSAT3B. This product is intended for use with foam inserts that were originally shipped with the CSAT3B.
Orderable29191
CSAT3B(H) Foam Case Set
The 29191 is the foam set used to protect the CSAT3B during transport and shipping.
Orderable30179
USB Data Cable, Type A Male to Type Mini-B Male, IP68, 5 m
The 30179 is a 5 m (16 ft) USB cable. One end has a standard type A male connector for easy connection to a PC. The opposite end has a mini-B male connector for connecting to a USB port on a sensor, such as the CSAT3B.
Orderable
Services
(3)16554
CSAT3A/B/BH/C Standard Calibration without CMM or Data
Provides calibration over the CSAT3B operating temperature range without using the coordinate measurement machine (CMM). No data are provided.
Orderable16555
CSAT3A/B/BH/C Calibration with CMM but without Data
Provides calibration over the CSAT3B operating temperature range and coordinate measurement of transducer positions in space relative to the bubble mounting surface. A CMM is used for this process. No data are provided.
Orderable38945
Sonic Anemometer Inspection, Diagnosis, and Evaluation
The 38945 service is for Campbell Scientific sonic anemometers (CSAT3, CSAT3A, CSAT3B, and CSAT3BH) that are sent in for repair service, but, after diagnosis, it is determined that the sensor cannot be repaired or calibrated, or repair is not required. This service fee covers the required sensor testing for the evaluation.
Orderable
Compatibility
The CSAT3B works with standard USB ports on most computers. However, for consistent communications—especially when using multiple USB devices or lower-powered ports (such as those on laptops or hubs without power)—we recommend using a powered USB hub for optimal performance.
Compatible Products
(1)Incompatible Products
(2)Related Resources
Case Studies
Documents
- Manual
CSAT3B Packing Information
January 2019
View Document - Compliance
CSAT3B EU Declaration of Conformity
March 2020
View Document - Compliance
CSAT3B FCC Supplier Declaration of Conformity and FCC Statement
March 2020
View Document - Brochure
CSAT3B 3-D Sonic Anemometer with Integrated Electronics
April 2026
View Document
Showing 4 of 9 results
See all DocumentsDownloads
- CSAT3B OSv3.02Login required
October 14, 2019
OS and FirmwareCurrent CSAT3B Operating System.
- CSAT3B Example Programsv1Login required
October 20, 2020
Software ApplicationsThree example programs. Simple SDM Program: SDM communications are used to collect data from a single CSAT3B. Simple CPI Program: CPI communications are used to collect data from a single CSAT3B. Advanced CPI Program: A single CSAT3B is properly configured and CPI communications are used to collect the data.
- CPI Calculatorv1.0Login required
July 6, 2016
Software ApplicationsThe CPI Calculator is a downloadable Microsoft Excel spreadsheet used to estimate the usage and capacity of a CPI network. The calculator provides an overview on CPI devices including the CDM-A108, CDM-A116, CDM-VW300, CDM-VW305, and the CSAT3B. The calculator can also estimate the measurement speed of the CDM-A108 and CDM-A116 based on the number of channels and measurement parameters. The CPI Calculator is an estimation tool and will help you better understand and design CPI networks by considering the following: What is the capability of each CDM or CPI device What is the CPI network capacity How much of the CPI capacity are the CDMs or CPI devices using