PS84 84Ah Power Supply w/14 x 16 Enclosure
 
Enclosure Hole Options
-SC -SC 1 Conduit for Cables
-DC -DC 2 Conduits for Cables
-NC -NC No Conduit/Entry Seal
Regulator Options
-NR -NR No Regulator
-SR -SR Sunsaver Regulator
-CR -CR CH200 Regulator
Enclosure Mounts
-NM -NM No Enclosure Mounting
-MM -MM Tripod Mast Mounting
-LM -LM CM1xx Leg Mounting
-TM -TM Tower Mounting
-PM -PM Pole Mounting, 4-10in

Add to your Quote List


Product Details
Restockable Yes
Warranty 1 year
Compliance
Ships With
(1) 7363 Enclosure Supply Kit, Standard Size
(1) 25962 84 Ah Battery
(1) 30066 Battery Terminal Bus Kit (quantity of 2)
(1) Red 18 AWG Power Wire w/ spade lug, 5 ft long
(1) Black 18 AWG Power Wire w/ spade lug, 5 ft long

Common Accessories

10525
 
The 10525 includes adhesive Velcro strips that secure desiccant to the inside door of the enclosure. Two packages of our 4-unit desiccant fit in this desiccant holder.
28701
 
The 28701 is bolted to the enclosure door. It contains a zipped bag for desiccant and an open pocket for documents.
CS210
 
The CS210 Enclosure Humidity Sensor contains an Elan HM2000-series precision bulk polymer relative humidity sensor. It senses relative humidity levels inside the environmental enclosure for the purpose of scheduling desiccant exchange. The desiccant should be exchanged when the sensor indicates an RH level of 35% or more inside the enclosure.
6714
 
The 6714 includes twenty 4-unit Silica Gel Desiccant Bags.

Replacement Parts

25660
 
The 25660 Bridge Grid Plate allows small peripherals to be mounted inside the PS84 power supply enclosure. The PS84 comes with one 25660, but more can be added using the 6044 grommet and 505 screw.
18529
 
The 18529 MorningStar SunSaver-10 10A 12V Regulator outputs up to 10 A at a nominal 12 Vdc. It accepts inputs from one or two solar panels,then regulates the voltage to charge an external battery. The regulator includes a 15-ft (4.6 m) cable to connect it to the rechargeable battery.
25962
 
The 25962 provides the PS84's sealed rechargeable battery, but without the mounting hardware that attaches the battery to the enclosure backplate. It may be purchased as a replacement item.
4419
 
The 4419 helps hold the PS84 in place.
5449
 
The 5449 ground lug is attached to the enclosure. It may be purchased to replace a lost or damaged ground lug.
23
 
The pn 23 nut is available as a replacement item.
30066
 
The 30066 consists of two battery-terminal bus stuffed circuit boards, plus an instruction sheet for using them on a large external battery.
7363
 
The enclosure supply kit includes desiccant, a humidity indicator card, cable ties, wire tie tabs, putty for sealing the conduit, and screws and grommets for attaching peripherals to the enclosure backplate.
25744
 
The 25744 and 25746 are the two parts used to create the standard conduit for Campbell Scientific enclosures. If a portion of the conduit for an ENC or PWENC enclosure becomes lost, the 25744 and 25746 can be ordered as replacements.
25746
 
The 25746 and 25744 are the two parts used to create the standard conduit for Campbell Scientific enclosures. If a portion of the conduit for an ENC or PWENC enclosure becomes lost, the 25746 and 25744 can be ordered as replacements.
560
 
The 560 screw is used to attach a backplate to the inside of an enclosure.
 
This 36 in.ground wire and lug connector can be purchased to replace a ground wire and lug connector that has been lost or damaged.
25659
 
This battery shelf can be ordered to replace a lost or damaged shelf.