CR206

Datalogger with 900 MHz Spread-Spectrum Radio
CR206

CR206

Retired

Datalogger with 900 MHz Spread-Spectrum Radio

No longer available to order

This product is retained for service, documentation, and compatibility information.

Replaced by

  • CR300

    Measurement and Control Datalogger

  • CR310

    Measurement and Control Datalogger

Model:
CR206
Item Number:
18179
Warranty:
1 year

Overview

The CR206 Datalogger features an on-board 900 MHz spread-spectrum radio with the functionality of the CR200 Datalogger. The CR206's input channel configuration and small size is optimal for measuring one or two sensors.

When paired with an ENC200 enclosure and the small 16869 battery, the packaged CR206 has a deployment size of only 6 in. by 7 in. This small package is optimal for the CR206 to be used as a wireless sensor within a PakBus network. The CR206 measures the sensors attached to it, then transmits its data wirelessly via its spread-spectrum radio to a master data logger. For more information on how to configure a PakBus system, please read our PakBus Networking Guide in the Related Documents section.

If an alternate spread-spectrum radio is required, see our CR211 and CR216 dataloggers.

Product Notes

see RF401 for antennas

Benefits

  • Ideal where only a few sensors will be measured
  • On-board 12 Vdc lead acid battery charger
  • Stores 128,000 data points (nonvolatile)
  • Data format is table-based
  • Replaces the CR205 datalogger

Specifications

-NOTE-
Note: Additional specifications are listed in the CR200-Series Specifications Sheet.
Internal Radio Operating Frequency Range
910 to 918 MHz
A/D Converter
12 bit
Scan Rate
Once per second

(maximum)

Single-Ended Analog Channels
5

(individually configured)

Analog Voltage Range
0 to +2500 mV
Measurement Resolution
0.6 mV
Excitation Channels
2

(programmable for either +2.5 or +5 volts)

Switched Battery Port
1
Pulse Count Channels
2
Control Ports
2
Battery Voltage Range
7 to 16 Vdc
Communications
RS-232

Other Accessories

(14)

Compatibility

Campbell Scientific’s SDM devices and multiplexers are not supported.

Sensors

The CR206 cannot make differential measurements and is not compatible with thermocouples, our geographic position sensor, fuel moisture/temperature probe, and soil heat flux sensors. However, it can measure a variety of sensors including SDI-12 sensors and 4 to 20 mA sensors. Our CS625 Reflectometer, 109 Thermistor, and CS15 Electric Current Sensor were specifically developed for our CR200-series dataloggers. Other compatible sensors include wind sets, tipping buckets, and barometers. For a complete list of compatible sensors, see the CR200-series brochure.

Communications

The CR206 can communicate with a PC via direct connect, NL100 Ethernet interface, MD485 multidrop modem, and our digital cellular modems. Data can be viewed on the CD295 DataView II display or a PDA (PConnect or PConnectCE software required).

The CR206's internal spread spectrum radio can transmit data to other CR206 loggers or RF401 spread spectrum radios. Certain CR206 settings must match the RF401 settings for communications between the data logger and radio to be successful. The factory default settings of these devices do not match; therefore, they must be reconfigured before communications can take place. Refer to the following application note for more information.

Quick Reference Guide for Setting Up RF401-to-CR206 Communications

If the CR206 is in the transparent mode, it can communicate with the retired CR205 loggers or RF400 radios.

Enclosures

Applications with minimal power requirements can use the ENC200 enclosure to house the data logger and the #16869 sealed rechargeable battery. The ENC200 cannot house a barometer or a battery that is larger than the #16869. However, an ENC10/12 or ENC12/14 enclosure is adequate for most CR206-based systems.

Power Supplies

When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 Ahr or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.

Compatible software

  • Short Cut
  • PC200W
  • PC400 (version 1.0 or higher)
  • LoggerNet (version 2.1 or higher)
  • PConnect (version 3.0 or higher)
  • PConnectCE (version 2.0 or higher)
  • VisualWeather (version 2.0 or higher)

Before March 2005, a CD was shipped with PakCom PC software and PakBus ActiveX (OCX). Effective, 3 March 2005, our DevConfig, PC200W, and Short Cut packages began to include support for the CR200-series dataloggers. These programs are available for download from our website or are on our ResourceCD.

Related Resources

Product Life Events

Available for Order
September 15, 2005
Calibration Available Until
July 30, 2010
Retired
July 30, 2010
Free Support Until
December 31, 2019
End of Life
December 31, 2019
Repair Available Until
December 31, 2019