BLACKGLOBE
BLACKGLOBE
OrderableTemperature Sensor for Measuring Heat Stress
Pricing
Request a quote Have pricing access? Sign in
Configuration
- w/3m (10 ft) per CableBLACKGLOBE-3mPart Number: 45367-3m
- w/5m (17 ft) per CableBLACKGLOBE-5mPart Number: 45367-5m
- w/10m (33 ft) per CableBLACKGLOBE-10mPart Number: 45367-10m
- w/15m (50 ft) per CableBLACKGLOBE-15mPart Number: 45367-15m
Select a configuration to add to your quote
- Model:
- BLACKGLOBE
- Item Number:
- 45367
- Warranty:
- 1 year
Overview
The Black Globe Temperature Sensor for Heat Stress (Black Globe) uses a thermistor inside a 15.2 cm (6 in.) hollow copper sphere, painted black, to measure radiant temperature. This measurement, along with the measurement of ambient air and wet-bulb temperatures, may be used to calculate the Wet-Bulb Globe Temperature (WBGT) index.
Note: The Black Globe includes four of the 7362 Eight-Inch UV-Resistant Black Cable Ties and one of the 29956 BlackGlobe Mounting Kit.
Key Advantages
Technical Description
Loss of physical and mental efficiency occurs under definable degrees of heat stress. Severe heat stress can lead to fatigue, exhaustion, and possibly even disability or death. The Wet-Bulb Globe Temperature (WBGT) index combines the effects of temperature, humidity, radiant heat, and wind into one single index employed to express environmental heat stress.
Heat stress can be reduced by decreasing the lengths of exposure and decreasing the workload of individuals under heat stress. Situation factors such as the type of clothing worn, the type of work performed, the psychological effects of stress, and availability of fluids can affect the assessment of heat stress. These factors are not easily quantified, and so the individual in a given situation must estimate their significance. Environmental factors such as temperature, humidity, and wind are more easily measured to assess heat stress.
To calculate the WBGT index, the measurement of the black globe (radiant heat), wet bulb (evaporative heat), and ambient air (dry bulb) temperatures are required. The wet-bulb temperature can be calculated using air temperature and relative humidity if a wet-bulb thermometer is not available.
A custom cable length will need to be specified when the Black Globe is ordered. The maximum suggested cable length is 304 meters (1,000 feet).
Specifications
- Temperature Measurement Range
- -5° to +95°C
- Temperature Survival Range
- -50° to +100°C
- Thermistor Interchangeability Error
- < ±0.2°C over 0° to 70°C, and ±0.3 at 95°C
- Polynomial Linearization Error
- < ±0.5°C
(over -7° to +90°C)
- Near Normal Emittance
- 0.957
Replacement Parts
(2)7362
8 in. UV-Resistant Black Cable Tie
The 7362 provides a Tefzel® 8 in. cable tie that is resistant to gamma radiation, UV radiation, and chemicals. Eight of these cable ties are included in the 7364 Cable Tie Kit. Four of these cable ties are shipped with the BlackGlobe. The 7362 may be ordered as a supply of additional ties.
Orderable29956
BlackGlobe Mounting Kit
The 29956 is the mounting kit that is shipped with the BlackGlobe. It allows the BlackGlobe to be attached to a crossarm or mast.
Orderable
Services
(2)SPTEMPCAL
Single-Point Calibration of Temperature Sensor at 25°C
A single-point calibration, STEMPCAL, is available when a thermistor has been purchased to determine offset at 25°C. (Calibration can be made at a different value if requested by purchaser.) Calibration uncertainty is ±0.05°C. Calibration after purchase requires an RMA (Return Material Authorization).
OrderableSPTEMPCAL2
Two-Point Calibration of Temperature Sensor at 0°C and Room Temperature
A two-point calibration, STEMPCAL2, is available when a thermistor has been purchased. The standard two-point calibration determines offsets at 0°C and 20 to 25°C (room temperature) with an uncertainty of ±0.05°C. If a sensor uses a different temperature range or an application requires the calibration to be made at different temperature values, different temperature points can be specified when the service is requested. Calibration after purchase requires an RMA (Return Material Authorization).
Orderable
Compatibility
Data Logger Considerations
The Black Globe requires an analog measurement. One single-ended and one excitation channel are required.