45223
45223
OrderableCS451 Pressure Transducer for OEMs
Pricing
Request a quote Have pricing access? Sign in
Configuration
- 0-2.9 psig (20 kPa), No Calibration Cert, w/Standard Nose Cone, No OEM Label, w/10m (33 ft) per SensorCS451OEM-SA-2-NC-SN-NL-10mPart Number: 45223-SA-2-NC-SN-NL-10m
- 0-7.25 psig (50 kPa), No Calibration Cert, w/Standard Nose Cone, No OEM Label, w/10m (33 ft) per SensorCS451OEM-SA-7-NC-SN-NL-10mPart Number: 45223-SA-7-NC-SN-NL-10m
- 0-14.5 psig (100 kPa), No Calibration Cert, w/Standard Nose Cone, No OEM Label, w/15m (50 ft) per SensorCS451OEM-SA-14-NC-SN-NL-15mPart Number: 45223-SA-14-NC-SN-NL-15m
- 0-29 psig (200 kPa), No Calibration Cert, w/Standard Nose Cone, No OEM Label, w/30m (100 ft) per SensorCS451OEM-SA-29-NC-SN-NL-30mPart Number: 45223-SA-29-NC-SN-NL-30m
- 0-72.5 psig (500 kPa), No Calibration Cert, w/Standard Nose Cone, No OEM Label, w/60m (200 ft) per SensorCS451OEM-SA-72-NC-SN-NL-10mPart Number: 45223-SA-72-NC-SN-NL-10m
- 0-145 psig (1000 kPa), w/Calibration Cert, w/NPT Fitting, Company F OEM Label, w/60m (200 ft) per SensorCS451OEM-SA-145-CC-NN-FL-60mPart Number: 45223-SA-145-CC-NN-FL-60m
Select a configuration to add to your quote
- Model:
- 45223
- Item Number:
- 45223
- Warranty:
- 1 year
Overview
This version of the CS451 pressure transducer is for OEMs. It does not have a label so that the OEM can attach their own branding.
Technical Description
The 45223 consists of a piezoresistive sensor and a temperature sensor housed in a 316L stainless-steel case. It has a rugged Hytrel cable that remains flexible, even under harsh environmental conditions. The cable incorporates a vent tube to compensate for atmospheric pressure fluctuations. The vent tube terminates inside a desiccant tube, which prevents water vapor from entering the inner cavity of the transducer.
The 45223 has several pressure range options and two accuracy options (see Ordering). The standard accuracy option provides ±0.1% FS TEB over the 0° to 60°C temperature range. The high accuracy option provides ±0.05% FS TEB over the 0° to 60°C temperature range and includes a calibration certificate. TEB is the combined errors due to nonlinearity, hysteresis, non-repeatability, and thermal effects over the compensated temperature range, per ISA S51.1. Please note that the high accuracy option is not available for the 0 to 2.9 psig range option.
Campbell Scientific offers the A150 Desiccated Case that allows the CS451 to be connected to a CWS900 Wireless Sensor Interface (for use in a wireless sensor network) or to be connected to a prewired enclosure (see Ordering Information).
Benefits
- Quality construction ensures product reliability
- Rugged stainless-steel case protects piezoresistive sensor
- Compatible with most Campbell Scientific dataloggers
- Fully temperature-compensated
- Low-power sleep state between measurements reduces power consumption
- Optional weighted nose cone facilitates submersion
- NPT fitting allows it to be used in closed-pipe applications
- Quick shipment after receipt of order (ARO)
- Compatible with the A150 Desiccated Case, which allows it to be connected to the CWS900 and used in a wireless sensor network
Specifications
- Measurement Time
- < 1.5 s
- Outputs
- SDI-12 (version 1.3) 1200 bps; RS-232 9600 bps
- Resolution
- 0.0035% FS
- Operating Temperature
- -10° to +80°C
WARNING: Sensor could be damaged if encased in frozen ice. - Compensated Temperature
- 0° to 60°C
WARNING: Sensor could be damaged if encased in frozen ice. - Temperature Accuracy
- ±0.2°C
- Overpressure
- 2 x pressure range
- Power Requirements
- 6 to 18 Vdc
- Cable Type
- Hytrel Jacket, five conductor, 26 AWG
- NPT Fitting
- 1/4-in. NPS
- Top Cone Material
- Delrin
- Body Material
- 316L stainless steel
- Element Material
- 316L stainless steel
- Distance
- 2.54 cm
(1 in.)
Distance from black line etched on housing to end of NPT fitting2.3 cm(0.9 in.)
Distance from black line etched on housing to end of standard nose cone9.9 cm(3.9 in.)
Distance from black line etched on housing to end of weighted nose cone - Diameter
- 21.34 mm
(0.84 in.)
- Length
- 213.36 mm
(6.875 in.)
- Cable Weight
- 0.0421 kg/m
(0.0283 lb/ft)
- Weight
- 0.17 kg
(0.37 lb) without cable
Power Consumption
- Quiescent
- < 50 µA
- Measurement/Communication
- 8 mA
(1 s measurement)
- Maximum
- 40 mA
Pressure Measurement Range
- Option -2
- ≤ 2.9 psig
(20 kPa)
- Option -7
- ≤ 7.25 psig
(50 kPa)
- Option -14
- ≤ 14.5 psig
(100 kPa)
- Option -29
- ≤ 29 psig
(200 kPa)
- Option -72
- ≤ 72.5 psig
(500 kPa)
- Option -145
- ≤ 145 psig
(1000 kPa)
Depth of Fresh Water Measurement Range
- Option -2
- ≤ 2.0 m
(6.7 ft)
- Option -7
- ≤ 5.1 m
(16.7 ft)
- Option -14
- ≤ 10.2 m
(33.4 ft)
- Option -29
- ≤ 20.4 m
(67 ft)
- Option -72
- ≤ 50.9 m
(167 ft)
- Option -145
- ≤ 102 m
(334.5 ft)
Accuracy
- Standard Accuracy Option
- ±0.1% full-scale-range TEB
Total Error Band (TEB) includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range, per ISA S51.1. - High Accuracy Option
- ±0.05% full-scale-range TEB
The high accuracy (±0.05% full-scale range) option is not available for the 0 to 2.9 psig range option.
Total Error Band (TEB) includes the combined errors due to nonlinearity, hysteresis, nonrepeatability, and thermal effects over the compensated temperature range, per ISA S51.1.
Maximum Cable Length
- SDI-12
- ~457 m
(1500 ft)
1 sensor connected to a single port60 m(200 ft)
10 sensors connected to a single port - RS-232
- 60 m
(200 ft)
Air Gap
- Standard & Weighted Nose Cone
- 0.653 cm
(0.257 in.)
- NPT Fitting
- 2.72 cm
(1.07 in.)
Common Accessories
(4)25431
Split Mesh Cable Grip, 0.180 to 0.250
The 25431 Split Mesh Cable Grip is recommended for use in wells to center the cable and to provide a method of suspending the cable, reducing cable stretch.
Orderable25366
Replacement Desiccant Tube for Pressure Transducers
The transducer's cable incorporates a vent tube that terminates inside of the 25366 desiccant tube. The 25366 is offered as a common accessory for customers who want a spare desiccant tube. The 25366 desiccant has a cobalt-free indicator that is orange and turns green when saturated. Please note: Prior to August 2019, the desiccant used in 25366 had a desiccant indicator that contained cobalt and would change color from blue to pink when saturated.
OrderableA200
Sensor to PC Interface
The A200 interfaces this transducer with a PC, allowing sensor settings to be changed via our Device Configuration Utility (DevConfig).
OrderableA151
Single Sensor Terminal Case, Vented with Desiccant
The A151 is a vented junction box with terminal blocks to connect sensors to an M12 eight-pin connector. It has accessories to allow the use of various lengths of cable and termination options.
Orderable
Services
(2)25425
Calibration with Data for the CS450, CS451, CS455, or CS456
The 25425 requires an RMA (Return Material Authorization) from Campbell Scientific. When it is ordered, we will calibrate the transducer to meet original specifications. Before and after calibration sheets are supplied with the pressure transducer.
Orderable27442
CS45X Recabling Service
The 27442 kit allows you to replace a damaged cable.
Orderable
Need Something Not Listed?
(45223)Don't see what you need from among these options? Download the complete configuration list below.
View all product configurationsSimilar Products
(1)Compatibility
Desiccated Case
The CS451 can be used with the A150. The A150 is a small, self-contained junction box that allows the CS451 to be connected to a continuation cable, a prewired-enclosure connector, or a CWS900-series wireless-sensor connector. Connection to a CWS900-series interface allows the CS451 to be part of a wireless sensor network.