SR50AH-L
 
SR50AH-L CSC Sonic Ranging Sensor w/Heater
 
SR50AH-L Options - show details
-L ft cable per sensor

Allowed values: 0-1000 ft, increments of 1 ft

-LH ft cable per heater

Allowed values: 0-200 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
Both the sensor cable and the heater cable terminate in pigtails that connect directly to the datalogger. The heater cable attaches to a switched 12 Vdc source.
-PW -PW w/Pre-Wire Connector

Add to your Quote List


Product Details
Restockable Yes
Warranty 2 years
Compliance CE Compliance Image RoHS Compliance Image
Ships With
(1) Test Report
(1) SR50ACBL-L Replacement Cable for SR50A

Common Accessories

19517
 
This mounting kit attaches directly to a CM206 crossarm or user-supplied pole with a 1-in. to 1.75-in. outside diameter.
19484
 
This mounting stem attaches to a sensor. The stem is then attached to the CM206 crossarm or a user-supplied pole via a CM220 mount, 17953 Nu-Rail fitting, or CM230 Adjustable Inclination Mount.
17953
 
The 17953 connects a vertical 1-inch pipe to a horizontal 1-inch pipe. The 17953 is typically used to attach a sensor with a 1-inch vertical pipe mount to a CM202, CM204, or CM206 crossarm. This usage provides functionality similar to the CM220 right-angle mounting bracket.
CM220
 
The CM220 right-angle mounting bracket can attach a sensor with a vertical pipe mount (e.g., most wind sensors) to a crossarm. It is compatible with pipes that have a 1- to 1.5-inch outer diameter.
CM230
 
The CM230 is an adjustable mount to point directional antennas or sensors at a specific target. The inclination can be adjusted to any angle from horizontal to vertical, supporting the use of upward-directed antennas or downward-directed infrared thermometers or snow-depth sensors.
CM230XL
 
The CM230XL is an adjustable mount to point directional antennas or sensors at a specific target. The inclination can be adjusted to any angle from horizontal to vertical, supporting the use of upward-directed antennas or downward-directed infrared thermometers or snow-depth sensors.

Other Accessories

33815
 
The 33815 makes it easier for you to connect wires from multiple SDI-12 sensors into one set of terminals on a data logger. The 33815 uses six DIN-rail mountable (pn 27479) 6-wire terminal blocks. The 33815 jumpers two connectors together at a time (pn 32918). This setup allows up to 11 SDI-12 sensors to be connected to one set of terminals on a data logger.

Replacement Parts

SR50ACBL-L
 
SR50ACBL-L Replacement SR50A Cable
 
Note: This heater cable is only replaceable via a Returned Material Authorization (RMA). This cable is available as a replacement item or as a "spare" cable. The SR50ACBL is fitted with a connector for attachment to the SR50AH. On the other end, the cable terminates in pigtails for connection to the datalogger.
SR50ACBL-L Options - show details
-L ft per sensor cable

Allowed values: 1-1000 ft, increments of 1 ft

Maximum cable length is 200 ft for the SDI-12 output, 200 ft for RS-232 output, and 984 ft for the RS-485 output.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a prewired enclosure.
-C -C w/ET/CS110 Connector
32571
 
The 32571 includes a transducer housing, desiccant, and a replacement O-ring. It is recommended that the transducer housing assembly be replaced every three years, or annually in high-humidity environments.
905
 
Two bags of the 905 desiccant are used inside the electronics housing. The 905 desiccant is not replaced when the transducer is replaced.
4091
 
Six bags of the 4091 desiccant are used to dry the air in the area above the transducer. Six bags are included in the transducer replacement kit.

Services

 
The 30249 is a service for the SR50A provided at the factory. All factory replacements require an RMA (Returned Material Authorization).