MS-80-L
 
MS-80-L EKO ISO 9060 Secondary Standard Pyranometer
 
MS-80 Options - show details
-L ft cable per sensor

Allowed values: 0-328 ft, increments of 1 ft

Cable Termination Options
-PT -PT w/Tinned Wires
-PW -PW w/Pre-Wire Connector

Add to your Quote List


Product Details
Restockable Yes
Warranty 5 years
Compliance CE Compliance Image RoHS Compliance Image
Ships With
(2) 25866 M5 x 30 mm Stainless-Steel Screw Cap Hex Socket
(4) Washers (M5)
(2) Nuts (M5)
(1) Sun Screen from original mfg
(1) Temperature Response Measurement Test from original mfg
(1) Cosine Response Measurement Test from original mfg
(1) Calibration Certificate (ISO/IEC 17025/9847) from original mfg
(1) Quick Start Guide from original mfg

Common Accessories

3WHB10K
 
One 3WHB10K is needed per MS-80-L sensor. The 3WHB10K provides the completion resistor required for a 3-wire half-bridge measurement.
CM255
 
One stand is needed per pyranometer. The CM255 is one of four options. The CM255 is used to mount the MS-80-L at an angle.
CMB200
 
The CMB200 Crossarm Brace Kit is designed to provide additional stability when using a crossarm mounted on Campbell Scientific tripods and towers. This kit provides support for crossarms with heavier or sensitive sensor loads, as well as added stability in higher winds. Each kit includes one brace arm and three sets of mounting brackets.

Replacement Parts

 
The 25866 may be purchased to replace a lost or damaged socket.
 
MS-80CBL-L MS-80 Replacement Cable
 
The MS-80CBL replacement cable uses pn 9720 cable, which is a two-twisted pair, 22 AWG cable with a Santoprene jacket. Insulation colors of the twisted pairs are red/black and green/white. An aluminum Mylar shield is grounded via a drain wire.
MS-80CBL Options - show details
-L ft per cable

Allowed values: 1-328 ft, increments of 1 ft

Cable Termination Options
-PT -PT w/Tinned Wires
-PW -PW w/Pre-Wire Connector

Services

33475
 
The 33475 recalibration service is performed using an intermittent shade method with a World Radiometric Reference (WRR) traceable AHF cavity radiometer. The 33475 recalibration is ISO 17025 accredited to the following standards: ASTM G167 and ISO 9846.
33476
 
The 33476 recalibration service is performed using a reference group of pyranometers traceable to World Radiometric Reference (WRR). This recalibration is ISO 17025 accredited to ASTM E824 standard.
33477
 
The 33477 recalibration service is performed indoors using a reference pyranometer of the same make and model. Reference pyranometers are traceable to the World Radiometric Reference (WRR). This recalibration is ISO 17025 accredited to ASTM G207 standard.