IRGASON
 
IRGASON Integrated CO2/H2O Open-Path Gas Analyzer & 3D Sonic Anemometer
 
Pressure Sensor Options - show details
-BB -BB Basic Barometer
Choose this option to get a barometer with a total accuracy of ±2.2 kPa (0° to +85°C).
-EB -EB Enhanced Barometer
Choose this option to get a barometer with a total accuracy of ±0.85 kPa (0° to +60°C).
Carrying Case Option - show details
-NC -NC No Carrying Case
Choose this option if you do not want an IRGASON® carrying case.
-IC -IC IRGASON Carrying Case
Choose this option if you want an IRGASON® carrying case.

Add to your Quote List


Product Details
Typically Ships Within 14 - 21 Days
Restockable Yes
Warranty 3 years or 17,500 hours
Compliance CE Compliance Image

The "Typically Ships Within" value is an estimate of the number of calendar days within which this product is ready to ship from Campbell Scientific. Orders with more than 10 built-to-order products will likely increase the time needed to prepare the order for shipping.

To estimate how long it will take to receive an order that contains multiple products, combine the longest Ships Within value with the transit time of the shipping method you select.

Some specialized products have long Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.

Ships With
(1) EC100 Replacement Gas Analyzer Electronics with Enclosure
(1) Certificate of Conformance
(1) Packing Information Sheet
(2) 17446 Stainless-Steel U-Bolt Screw 5/16-18 x 1.500 with Silicon Bronze Nuts
(2) 17492 Stainless-Steel U-Bolt Screw 5/16-18 x 2.125 with 2 Silicon Bronze Nuts
(1) 26520 IRGASON and EC150 Replacement Temperature Probe
(12) 2207 4 in. Nylon Cable Tie
(1) CM250 Leveling Mounting Kit
(1) 26563 USB Data Cable, Type A Male to IP68 Panel Type Mini-B Male, 4.5 m
(1) 27798 Foam Insert
(1) 41303-5A 6-Plate Solar Radiation Shield
(1) 4905 Desiccant 4-Unit Bag
(1) 8125 Flat-Bladed Screwdriver, 2.5 mm Blade x 50 mm Shaft
(1) 32897 13X Chemical Molecular Sieve Bottles for IRGASON and EC150

Common Accessories

CABLEPCBL-L
 
CABLEPCBL-L 2-Conductor 16AWG Power Cable
 
This 16 AWG, two-conductor cable with a Santoprene jacket is used to power the IRGASON®.
CABLEPCBL-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, there is a pre-wired connector on one end of the cable.
CABLE4CBL-L
 
CABLE4CBL-L 4-Conductor 22AWG Cable w/Drain
 
This 4-conductor, 22 AWG cable with drain wire and Santoprene jacket is used to attach the SDM connector on the EC100 electronics box.
CABLE4CBL-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
Choose this option if you are using this cable with a pre-wired enclosure.
26390
 
The 26390 is a zero and span shroud kit. A zero and span should be done when ambient conditions change significantly (i.e., seasonally).
31022
 
The Zero Air Generator is a low-cost, handheld source of zero air (air that has been scrubbed of CO2 and water vapor) to be used for zeroing infrared gas analyzers (IRGAs). The 31022 consists of a small pump and a molecular sieve. The pump is powered by 2 AA batteries.
27278
 
The 27278 is a lab stand kit for the IRGASON®.
30217
 
The 30217 is a kit that allows a fine-wire thermocouple to be mounted alongside an IRGASON®. The kit includes a mounting bracket that bolts directly to the CM250 Leveling Mount. The 30217 replaces the 27497 mounting bracket that is included with the IRGASON®.
FW05
 
At least two FW05 thermocouples per IRGASON® are needed; four are recommended. The FW05 consists of a 0.0005" diameter, type E thermocouple mounted on a stainless-steel bayonet. This thermocouple features a simplified junction design over its predecessor, the FWTC05. The FW05's measurement junction resembles that of the 127 thermocouple, used with CA27. The FW/ENC carry case is required (see below).
FW/ENC
 
An FW/ENC Fine Wire Carrying Case is required to ship or carry the fine wire thermocouples. The case can house up to four FW05s.
FWC-L
 
FWC-L Connector Cable for Fine Wire TCs
 
An FWC-L Connector Cable is required for each FW05 ordered. A 35-foot cable length (i.e., FWC-L35) is recommended; four feet of this cable should be bundled inside of the enclosure to minimize heat conduction on the terminal strips. The remaining 31 feet is for mounting the FW05 onto the side of the IRGASON® head.
Cable Length - show details
-L ft cable per sensor

Allowed values: 1-1000 ft, increments of 1 ft

A 20 ft lead length (FWC-L20) is recommended for most applications.
10080
 
The 10080 Thermocouple Cover is placed over the Omega-brand thermocouple connectors and is used to mount the connectors to the side of the IRGASON® head. It also minimizes temperature gradients across the connectors.

Other Accessories

 
CABLE2TP-L 2 Twisted Pair 22AWG Cable w/Drain
 
This cable is needed to connect the Analog Output on the IRGASON® electronics box if using analog output rather than SDM. It is a two-twisted pair, 22 AWG cable with drain wire and Santoprene jacket.
CABLE2TP-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
Choose this option if you are using this cable with a prewired enclosure.
CABLE3TP-L
 
CABLE3TP-L 3 Twisted Pair 24AWG Cable w/Drain
 
This cable is needed to connect the IRGASON® with an MD485 RS-485 multidrop interface if using RS-485 (<500 ft length) rather than SDM. It is a three-twisted pair, 24 AWG cable with drain wire and a Santoprene jacket.
CABLE3TP-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
EasyFlux WebS
 
EasyFlux™ Web Self-Hosted is a web-based software tool for monitoring CR6- and CR3000-based Campbell Scientific, Inc. eddy-covariance systems. EasyFlux™ Web Self-Hosted is a user-installed version of EasyFlux™ Web that allows users the ability to install on their own server and control updates of the software themselves.
EasyFlux WebH
 
EasyFlux WebH EasyFlux Web Software CSI-Hosted One-Time Implementation Fee
 
EasyFlux™ Web CSI-Hosted is a web-based software tool for monitoring CR6- and CR3000-based Campbell Scientific, Inc., eddy-covariance systems. EasyFlux™ Web CSI-Hosted is hosted on Campbell Scientific's own Microsoft Azure server, which allows for automatic updates and maintenance of the software. After users create an account, they are given their own IP address to allow them to easily connect to their data from an Internet-connected device. Monitoring a network of eddy-covariance systems is made easy with real-time data monitoring, customizable alerts, and data download capabilities. EasyFlux™ Web is compatible with open- and closed-path eddy-covariance systems.
Number of Sites
-S5 -S5 Fee for 1-5 sites
-S10 -S10 Fee for 6-10 sites
-S15 -S15 Fee for 11-15 sites
-S20 -S20 Fee for 16-20 sites
EasyFlux PC
 
EasyFlux™ PC is a free computer program that processes high frequency time series data, collected using a Campbell Scientific eddy-covariance flux system, into fluxes following community accepted practices. Fully corrected fluxes of CO2, latent heat (H2O), sensible heat, and momentum are available, in generic, AmeriFlux, and GHG-Europe ASCII formats.
EasyFlux DL
 
EasyFlux™ DL is a free CRBasic program that enables a datalogger to report fully corrected fluxes of CO2, latent heat (H2O), sensible heat, and momentum from a Campbell Scientific open-path eddy-covariance (EC) system. Final fluxes are processed from raw high frequency time series data by applying commonly used corrections found in scientific literature.

Replacement Parts

EC100
 
The EC100 is an electronics module used with Campbell Scientific's CO2/H2O gas analyzers and CSAT3A sonic anemometer head.
28902
 
The sonic wick spares kit is used to replace wicks on a CSAT3, CSAT3A, or IRGASON®. It includes three top wicks, three bottom wicks, an installation tool, and some adhesive.
 
This wick can be placed on the bottom snout of the gas analyzer to help wick away rain droplets from the optical window. Recommended for sites with frequent rain.
 
This wick can be placed on the top snout of the gas analyzer to help wick away rain droplets from the optical window. Recommended for sites with frequent rain.
 
The 30748 includes a bubble level and three screws to replace a lost or damaged part.
CM250
 
The CM250 is a leveling mount kit for attaching the IRGASON® to a crossarm.
26520
 
This special temperature probe is shipped with the EC150 and has a 10 ft cable.
4905
 
The 4905 Single 4-Unit Silica Desiccant Bag is packaged in Tyvek. It is used to desiccate most enclosures (as part of 7363) and weather stations (e.g., 012 - 1 package shipped). The supplied desiccant should fill the initial needs of most applications, but should be periodically replaced. (The 4905 can be purchased in quantities of 20 as part number 6714.)
3768
 
This green, plug-in power connector provides screw terminals for connecting the 12V and G wires.
29991
 
The 29991 is available for replacement if the original carrying case, ordered as an option, has been lost or damaged.
2207
 
The cable ties are constructed from a flexible, nylon material. A connection is made by pulling the tapered end through the locking end, thus forming a loop. The free end is pulled tight to secure the cables, then trimmed back to the locking end. Once attached, the cable tie must be cut to be removed.
26563
 
The cable is 4.5 m long. It may be purchased to replace a lost or damaged cable.
17492
 
The 17492 provides a 5/16" U-bolt and two nuts. This product is used to mount solar panels, mounts, enclosures, or sensors to a mast, tower, or pole.
17446
 
The 17446 provides a U-bolt and two nuts as a replacement for the original U-bolt and nuts.
8125
 
The 8125 is a small, flat-bladed screwdriver that is extremely useful for opening the guillotine terminals on our dataloggers and measurement control devices.
32897
 
The 32897 contains two desiccant/scrubber bottles utilizing a non-hazardous molecular sieve. These are maintenance replacement parts for the IRGASON®. Each bottle contains necessary chemicals and membrane filters for scrubbing CO2 and water vapor from the gas analyzer housing.
 
The Spare Gas Head Wick Kit for the EC150 and IRGASON® includes two gas analyzer head wicks—one for the bottom window and one for the top. These wicks help prevent water from collecting on the window surfaces and minimize signal attenuation.

Services

30389
 
The 30389 provides recalibration of the gas analyzer and sonic anemometer including a new CMM measurement, followed by a zero and span. When sensor diagnostics indicate a problem, the instrument should be sent back for recalibration. An RMA is required.
 
A zero and span should be done when ambient conditions change significantly (i.e., seasonally). If the user does not have a zero/span kit to do this himself/herself, it can be sent in to Campbell Scientific. An RMA is required.