HMP60-L
 
HMP60-L Vaisala Temperature/RH Probe
 
HMP60-L Options - show details
-L ft cable per probe

Allowed values: 0-1000 ft, increments of 1 ft

Campbell Scientific recommends:
  • 9 ft length—probe mounted to mast/leg at a 2 m height
  • 11 ft length—probe mounted to a CM202 at 2 m height
  • 14 ft length—probe mounted atop a CM106B, CM110,or UT10 via a CM202
  • 19 ft length—probe mounted atop a CM115 via a CM202
  • 24 ft length—probe mounted atop a UT20 via a CM202
  • 37 ft length—probe mounted atop a UT30 via a CM202
Add two feet to the cable length if you are mounting the enclosure on the leg base of a CM106B, CM110, CM115, or CM120 tripod.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a prewired enclosure.
-CWS -CWS w/CWS900 Connector
With the -CWS option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows this sensor to be used in a wireless sensor network.
-C -C w/ ET/CS110 Connector
With the -C option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.

Add to your Quote List


Product Details
Restockable Yes
Warranty 1 year
Compliance CE Compliance Image

Common Accessories

RAD06
 
The RAD06 uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion. It also has lower self-heating in bright sunlight combined with higher temperatures (> 24°C (~75°F)) and low wind speeds (< 2m/s (~4.5 mph)), providing a better measurement.
41303-5A
 
The 41303-5A provides a six-plate naturally-aspirated radiation shield that houses one HMP60 probe. Its louvered construction allows air to pass freely through the shield thereby keeping the probe at or near ambient temperature. The 41303-5A attaches to a crossarm, mast, or user-supplied pipe with a 1.0" to 2.1" OD.

Other Accessories

41003-5
 
The 41003-5 10-plate radiation shield can be used instead of the 41303-5A six-plate shield, but additional hardware is required (see below).
41322
 
The 41322 adapter plate is used to mount an HMP60 probe in the lower part of a 41003-5 10-plate radiation shield.
RAD10
 
The RAD10 uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion. It also has lower self-heating in bright sunlight combined with higher temperatures (> 24°C (~75°F)) and low wind speeds (< 2m/s (~4.5 mph)), providing a better measurement.

Replacement Parts

 
HMP60CBL-L Replacement HMP60-L Cable
 
The HMP60CBL connects the HMP60 sensor head with input and power terminals on the datalogger.
HMP60CBL-L Options - show details
-L ft per sensor cable

Allowed values: 1-1000 ft, increments of 1 ft

Campbell Scientific recommends:
  • 9 ft length—probe mounted to mast/leg at a 2 m height
  • 11 ft length—probe mounted to a CM202 at 2 m height
  • 14 ft length—probe mounted atop a CM106B, CM110, or UT10 via a CM202
  • 19 ft length—probe mounted atop a CM115 via a CM202
  • 24 ft length—probe mounted atop a UT20 via a CM202
  • 37 ft length—probe mounted atop a UT30 via a CM202
Add two feet to the cable length if you are mounting the enclosure on the leg base of a CM106B, CM110, CM115, or CM120 tripod.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a prewired enclosure.
-CWS -CWS w/CWS900 Connector
With the -CWS option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows this sensor to be used in a wireless sensor network.
-C -C w/ ET/CS110 Connector
9598
 
The 9598 RH Chip is field-replaceable, as needed, eliminating the downtime typically required for the recalibration process. Chip replacement is recommended every 2 to 3 years depending on the application.
32235
 
The 32235 has a 12 mm sensor filter. It is metal-coated PPS plastic with a PTFE membrane. The pore size is 0.2 µm.