CS456
 
CS456 Pressure Transducer SDI-12 /RS-232, Titanium
 
Cable Length Options
-15 -15 w/15ft per Probe
-17 -17 w/17ft per Probe
-30 -30 w/30ft per Probe
-33 -33 w/33ft per Probe
-50 -50 w/50ft per Probe
-75 -75 w/75ft per Probe
-83 -83 w/83ft per Probe
-100 -100 w/100ft per Probe
-200 -200 w/200ft per Probe
-U -U w/User Defined Length
-U User Specified Length - show details
  -L ft cable per sensor

Allowed values: 1-1500 ft, increments of 1 ft

 
Accuracy Options - show details
-SA -SA Std 0.1% Accuracy
A calibration certificate that contains calibration information specific to the individual sensor is shipped with each unit.
-HA -HA Higher 0.05% Accuracy
The high accuracy option provides ±0.05% FS over the 0° to 60°C temperature range. A calibration certificate that contains calibration information specific to the individual sensor is shipped with each unit.
-SA Pressure Ranges - show details
  -7 -7 0-7.25psig (50kPa)
Select this range if the anticipated pressure on the transducer will never exceed 7.25 psig (50 kPa), which is equivalent to 5.1 m (16.7 ft) of fresh water.
  -14 -14 0-14.5psig (100kPa)
Select this range if the anticipated pressure on the transducer will never exceed 14.5 psig (100 kPa), which is equivalent to 10.2 m (33.4 ft) of fresh water.
  -29 -29 0-29psig (200kPa)
Select this range if the anticipated pressure on the transducer will never exceed 29 psig (200 kPa), which is equivalent to 20.4 m (67 ft) of fresh water.
  -72 -72 0-72.5psig (500kPa)
Select this range if the anticipated pressure on the transducer will never exceed 72.5 psig (500 kPa), which is equivalent to 50.9 m (167 ft) of fresh water.
  -145 -145 0-145psig (1000kPa)
Select this range if the anticipated pressure on the transducer will never exceed 145 psig (1000 kPa), which is equivalent to 102 m (334.5 ft) of fresh water.
-HA Pressure Ranges - show details
  -14 -14 0-14.5psig (100kPa)
Select this range if the anticipated pressure on the transducer will never exceed 14.5 psig (100 kPa), which is equivalent to 10.2 m (33.4 ft) of fresh water.
  -29 -29 0-29psig (200kPa)
Select this range if the anticipated pressure on the transducer will never exceed 29 psig (200 kPa), which is equivalent to 20.4 m (67 ft) of fresh water.
  -72 -72 0-72.5psig (500kPa)
Select this range if the anticipated pressure on the transducer will never exceed 72.5 psig (500 kPa), which is equivalent to 50.9 m (167 ft) of fresh water.
  -145 -145 0-145psig (1000kPa)
Select this range if the anticipated pressure on the transducer will never exceed 145 psig (1000 kPa), which is equivalent to 102 m (334.5 ft) of fresh water.
 
Nose Cone Options - show details
-SN -SN w/Standard Nose Cone
Choose this option for standard applications.
-WN -WN w/Weighted Nose Cone
This weighted nose cone makes it easier to submerge the transducer to depth.
-NN -NN w/NPT Fitting
An NPT nose cone allows the transducer to be used in closed-pipe applications. The NPT nose cone option has a 1/4 in. NPT fitting.

Add to your Quote List


Product Details
Typically Ships Within 14 - 21 Days
Restockable Yes
Warranty 1 year
Compliance CE Compliance Image RoHS Compliance Image

The "Typically Ships Within" value is an estimate of the number of calendar days within which this product is ready to ship from Campbell Scientific. Orders with more than 10 built-to-order products will likely increase the time needed to prepare the order for shipping.

To estimate how long it will take to receive an order that contains multiple products, combine the longest Ships Within value with the transit time of the shipping method you select.

Some specialized products have long Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.

Ships With
(1) Calibration Certificate

Common Accessories

25431
 
The 25431 Split Mesh Cable grip is recommended for use in wells to center the cable and to provide a method of suspending the cable, reducing cable stretch.
25366
 
The transducer's cable incorporates a vent tube that terminates inside of the 25366 desiccant tube. The 25366 is offered as a common accessory for customers who want a spare desiccant tube.
A200
 
The A200 interfaces a CS456 with a PC, allowing sensor settings to be changed via our Device Configuration Utility (DevConfig).
A150-L
 
A150-L Single Sensor Terminal Case, Vented w/Desiccant
 
The A150 desiccated case is a small, self-contained junction box that allows the CS456 to be connected to a PWENC connector.
A150-L Options - show details
-L ft per cable

Allowed values: 0-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a prewired enclosure.
-CWS -CWS w/CWS900 Connector
With the -CWS option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
31648
 
The 31648 is a clamp with 1 in. NPT threads that allows the CS456 to be mated with a 1 in. PVC pipe for installations purposes. A 1 in. female adapter socket with FPT threads is needed between the 31648 and 1 in. PVC pipe. This adapter socket is typically available at stores that sell PVC pipe.

Replacement Parts

25366
 
The 25366 may be purchased to replace a damaged desiccant tube. The CS456 is shipped with this small desiccant tube attached to it. The transducer's cable includes a vent tube that terminates inside of the 25366. The desiccant tube prevents water vapor from entering the inner cavity of the transducer.
29137
 
The 29137 is replacement desiccant for this transducer's desiccant tube. It provides enough desiccant to fill ten desiccant tubes.

Services

 
The 25425 requires an RMA (Returned Material Authorization) from Campbell Scientific. When it is ordered, we will recalibrate the transducer to meet original specifications. Before and after calibration sheets are supplied with the pressure transducer.