Product Details
Typically Ships Within 0 - 7 Days
Restockable Yes
Warranty 1 year
Compliance CE Compliance Image RoHS Compliance Image

The "Typically Ships Within" value is an estimate of the number of calendar days within which this product is ready to ship from Campbell Scientific. Orders with more than 10 built-to-order products will likely increase the time needed to prepare the order for shipping.

To estimate how long it will take to receive an order that contains multiple products, combine the longest Ships Within value with the transit time of the shipping method you select.

Some specialized products have long Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.

Ships With
(2) 7364 UV-Resistant 8 in. Cable Ties (quantity of 12)
(1) 27015 Heat-Resistant Kapton Tape with Silicone Adhesive
(2) 110PV-L 110PV-L15-PT surface mount thermistor
(1) 1113 Flat-Bladed Screwdriver, 3.0 mm Blade x 60 mm Shaft
(4) 6044 Grommet for #6 or 8 Screw
(4) 505 Screw #6-32 x .375 Pan Phillips
(1) 27555 USB 2.0 Cable, Type A Male to Micro B Male, 6/6.5 ft
(1) 33045 CR-PVS1 Quick Deploy Guide
(1) CR300 Calibration Documentation
(1) USB Flash Drive with Device Configuration Utility software

Other Accessories

SC110
 
The SC110 consists of two cables to connect a datalogger with RS-232 DCE and DTE devices. One end of each cable provides stripped, tinned leads for attachment to the control ports on a CR800, CR850, CR1000, CR3000, or CR6 datalogger. On the other end, one of the cables is fitted with a 9-pin male connector, and the other cable is fitted with a 9-pin female connector.
MD485
 
MD485 RS-485 Multidrop Interface
 
The MD485 is an intelligent RS-485 interface that permits a PC to address and communicate with one or more dataloggers over a distance of up to 1200 m. This interface also supports datalogger-to-datalogger communication, callback from a remote datalogger, PC-to-printer communications, and digital camera-to-datalogger connections.
Temperature Ranges - show details
-ST -ST -25 to +50C
The Standard Temperature Testing range is -25° to +50°C. Individual units are warranted to perform within published specifications over this range, which is included with product purchase.
-XT -XT -55 to +85C
Extended Temperature Testing over the -55° to +85°C range is also available. Individual units are subjected to performance tests at these extremes in a test chamber. Units that pass the tests are certified as extended temperature units.

Please note that manual operation of the "Program" button in MD485s may be compromised at extended low temperatures (-25° to -55°C). The Program button is used only when configuration settings are being manually downloaded to the device from a computer.
Warranty Lengths - show details
-SW -SW Standard 1yr Warranty
At the time of purchase, the MD485 includes a standard warranty of 12 months. See our full warranty policy in the MD485 manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our Extended Warranty adds 48 months to the standard 12 month warranty, bringing the total warranty period to 60 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
NL201
 
NL201 Network Link Interface
 
The NL201 is a serial-to-Ethernet interface that provides a wired Ethernet network connection to dataloggers, peripherals, and other serial devices. The NL201 supports sophisticated networking capabilities for PakBus devices and networks.
Temperature Ranges - show details
-ST -ST -25 to +50C
Every NL201 is tested and guaranteed to perform within published specifications over the standard temperature range. Units are tested and shipped to standard operating range unless extended testing is specified.
-XT -XT -55 to +85C
Extended Temperature Testing over the -55° to +85°C range is available. Individual units are subjected to performance tests at these extremes in a test chamber. Units that pass the tests are certified as extended temperature units.
Warranty Lengths - show details
-SW -SW Standard 1yr Warranty
At the time of purchase, the NL201 includes a standard warranty of 12 months. See our full warranty policy in the NL201 manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our Extended Warranty adds 48 months to the standard 12 month warranty, bringing the total warranty period to 60 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
RV50
 
RV50 RV50 Sierra Wireless Airlink 4G Industrial LTE Cellular Gateway
 
The RV50 is an industrial 4G LTE cellular gateway that provides serial and Ethernet connectivity to numerous cellular networks. The RV50 is capable of LTE, CDMA/EV-DO, and GSM/GPRS/EDGE/WCDMA networking and is carrier-approved in North America for Verizon, AT&T, T-Mobile USA, Rogers, Bell, and Telus. The networking and carrier used by the RV50 is determined by the active SIM card(s) inserted into the device. The RV50 does not ship with a SIM card; the SIM card is provided by the carrier when signing up for service. The RV50 automatically falls back to 3G or 2G when 4G coverage is not available.
Country of Usage Option
-NA -NA North America Model
-INT -INT International Model
SP10
 
SP10 10W Solar Panel, 20ft Cable
 
The SP10 is a 10-W photovoltaic power sources capable of recharging batteries. Its 6.1 m (20 ft) cable has stripped and tinned leads that connect to the PS150, PS200, CH150, CH200, or battery base of the CRVW3, CR3000, CR5000, CR7, CR9000X, or CR6.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a pre-wired enclosure.
-C -C w/ ET/CS110 Connector
With the -C option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station. This is equivalent to the -LC version available for some sensors.
Mounting Options - show details
-SM -SM Std Mounting Kit
Standard mounting to allow solar panel to be mounted directly to the leg of a tower or crossarm.
-EM -EM Extended Mounting Kit
Extended Mounting Kit allows the solar panel to be mounted on a tower or crossarm that puts the panel approximately 25.4 cm (10 in.) from the mast. This reduces shadows on the solar panel from other components or guy wires, which negatively affects the performance of the solar panel. It does, however, increase the wind load on the system.
SP20
 
SP20 20W Solar Panel, 15ft Cable
 
The SP20 is a 20 W solar panel. It is often used for system configurations that have higher-than-average power requirements, or in higher elevation and latitude locations. It connects to Campbell Scientific power supplies and battery bases to recharge the battery, and it allows unattended operation of systems in remote locations that are far from ac electrical sources.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a pre-wired enclosure.
Mounting Options - show details
-SM -SM Std Mounting Kit
Standard mounting to allow solar panel to be mounted directly to the leg of a tower or crossarm.
-EM -EM Extended Mounting Kit
Extended Mounting Kit allows the solar panel to be mounted on a tower or crossarm that puts the panel approximately 25.4 cm (10 in.) from the mast. This reduces shadows on the solar panel from other components or guy wires, which negatively affects the performance of the solar panel. It does, however, increase the wind load on the system.
SP50-L
 
SP50-L 50W Solar Panel
 
The SP50-L is a 50 W solar panel used in systems with large power requirements, but not as great as that provided by the 90 W SP90-L. Its cable length is user-specified and attaches to and recharges 12 V flooded batteries.
SP50-L Options - show details
-L ft cable per SP50

Allowed values: 1-50 ft, increments of 1 ft

A 20-ft length is typical; maximum length is 50 ft.
Cable Termination Options
-PT -PT w/Tinned Wires
-PW -PW w/Pre-Wire Connector
SP90-L
 
SP90-L 90W Solar Panel
 
The SP90-L is a 90 W solar panel used in systems with large power requirements. It recharges 12 V batteries. Its cable length is user-specified, and the SP90 allows unattended operation of systems in remote locations, far from ac electrical sources.
SP90-L Options - show details
-L ft cable per SP90

Allowed values: 1-50 ft, increments of 1 ft

Cable Termination Options
-PT -PT w/Tinned Wires
-PW -PW w/Pre-Wire Connector
28370
 
28370 24Vdc 3.8A NEC Class 2 Power Supply Kit (Battery Not Included)
 
The 28370 is a 24 Vdc power-supply kit that includes a 24 Vdc, 3.8 A power supply, along with hardware for mounting and wiring inside standard Campbell Scientific enclosures. The 28370 with the -UL option, as well as part number 27623, are used in UL508A-certified enclosures assembled at Campbell Scientific.
Kit Type
-SK -SK Standard Kit
-UL -UL UL508A Kit
BP7
 
The BP7 is a rechargeable, 12 V, 7 Ah battery that can power a Campbell Scientific system that has components that have average power requirements, such as satellite transmitters. This battery is typically recharged with a panel or wall charger.
BP12
 
The BP12 is a rechargeable, 12 V, 12 Ah battery pack that can power a Campbell Scientific system that has components that have above-average power requirements, such as satellite transmitters.
BP24
 
The BP24 is a rechargeable 12 Vdc, 24 Ah battery pack that can power a Campbell Scientific system. It is intended for high-current-drain systems, such as satellite transmitters, that require more power.
BP84
 
The BP84 is a rechargeable 12 Vdc, 84 Ah battery pack that can power a system with larger power requirements. It is typically used when access to ac power is not available.
 
CABLEPCBL-L 2-Conductor 16AWG Power Cable
 
The CABLEPCBL-L is a 16 AWG, two-conductor cable with a Santoprene jacket. The conductors are stripped and tinned. This generic cable is used to power remote peripherals.
CABLEPCBL-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector

Replacement Parts

110PV-L
 
110PV-L Surface-Mount Temp Probe (-40 to +135C)
 
The 110PV is a thermistor that measures the temperature of a surface by direct contact.
110PV-L Options - show details
-L ft cable per probe

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options
-PT -PT w/Tinned Wires
-PW -PW w/Pre-Wire Connector
-CWS -CWS w/CWS900 Connector
 
The 27015 is a 5 yd roll of Kapton Tape. This tape is recommended for fastening our surface mount temperature sensors to their measurement surface when the temperature may exceed 70°C.
7364
 
The 7364 includes 12 Tefzel® 8 in. cable ties (pn 7362) that are resistant to gamma radiation, UV radiation, and chemicals.
1113
 
The 1113 is used to attach sensor leads to screw terminals.
505
 
These screws, along with the 6044 grommets, are commonly used together to secure our equipment to the backplates of our enclosures.
6044
 
These grommets are commonly used with the 505 screws to secure our equipment to the backplates of our enclosures.
27555
 
The 27555 is a USB Type A to Micro B, male-to-male cable, 6 to 6.5 ft long. It connects devices using the Micro B interface to a USB port on a computer.

Services

 
The 31972 requires an RMA (Returned Material Authorization) from Campbell Scientific. When ordered, we recalibrate the CR300 to meet original specifications. Recalibration includes standard temperature testing (-40° to +70°C). Before and after calibration sheets are supplied with the CR300.