AP200
 
AP200 CO2/H2O Atmospheric Profile System
 
IRGA Options - show details
-NA -NA No IRGA
Choose this option if you already have an LI-840A gas analyzer.
-GA -GA LI-840A Gas Analyzer
This option provides a LI-840A Gas Analyzer.
Communication Options - show details
-NCM -NCM No Comms Module
Choose this option if you want to use your own NL115 or CFM100 to store data.
-NL -NL NL116 Module
-CF -CF CFM100 Module
Internal Keyboard Options - show details
-NK -NK No Internal Keyboard
Choose the -NK option if you do not want a CR1000KD mounted inside the AP200 enclosure or if you already have a CR1000KD and don't care to have it mounted.
-KD -KD w/Keyboard & Display
Choose this option if you want a CR1000KD mounted inside of the AP200 enclosure.
Enclosure Mounts - show details
-NM -NM No Enclosure Mounting
-MM -MM Tripod Mast Mounting
Choose the -MM option to mount the AP200 enclosure on a tripod mast or a pole.
-LM -LM CM106 Leg Mounting
Choose the -LM option to mount the AP200 enclosure to the leg base of a CM106 tripod.
-TM -TM Tower Mounting
Choose the -TM option to mount the AP200 enclosure on a tower's legs.
-PM -PM Pole Mounting, 4-10in
Choose the -PM option to mount the AP200 enclosure on a large diameter pole with a 4" to 10" outer diameter.
AP200 Options - show details
-I -I Intake Assemblies

Allowed values: 4-8 ea, increments of 1 ea


Add to your Quote List


Product Details
Typically Ships Within 14 - 21 Days
Restockable Yes
Warranty 1 year
Compliance CE Compliance Image RoHS Compliance Image

The "Typically Ships Within" value is an estimate of the number of calendar days within which this product is ready to ship from Campbell Scientific. Orders with more than 10 built-to-order products will likely increase the time needed to prepare the order for shipping.

To estimate how long it will take to receive an order that contains multiple products, combine the longest Ships Within value with the transit time of the shipping method you select.

Some specialized products have long Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.

Ships With
(8) Spare AP200 Intake Filters, 3 micron
(1) 28552 Support CD containing CR1000 Program
(1) 29236 AP200 Enclosure desiccant pack
(1) 29237 AP200 Enclosure fittings & tools pack
(11) Swagelok nut with ferrules

Common Accessories

15702
 
The 15702 tubing is required for the sample intake assemblies. Order enough tubing to connect all of the sample intake assemblies to the bottom of the enclosure. Maximum roll length is 500 ft.
9922
 
The 9922 is a 20 AWG power cable used to power a heater on the orifice of each intake assembly. The power cable is normally daisy-chained from the enclosure to all the intake assemblies (e.g. one cable connects the enclosure to an intake assembly, and then another cable connects that intake assembly to the next intake assembly, and so on). Select the total length needed and then cut the cable into smaller lengths on-site to do the daisy-chaining.
CABLEPCBL-L
 
CABLEPCBL-L 2-Conductor 16AWG Power Cable
 
One CABLEPCBL is needed per system; choose the -PT cable termination option. This 16-AWG, two-conductor cable has a Santoprene® jacket and stripped and tinned conductors.
CABLEPCBL-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, there is a pre-wired connector on one end of the cable.
CFMC2G
 
The CFMC2G is an industrial-grade CompactFlash card with a 2 GB storage capacity. The card is formatted as FAT32.
17752
 
The 17752 is a single slot, high-speed reader/writer that allows a computer to read data stored on CompactFlash card. The 17752 connects to the computer's USB port.
41303-5A
 
The 107 needs to be housed in the 41303-5A, a naturally aspirated, 6-plate radiation shield. The 41303-5A can attach to a crossarm, mast, or a user-supplied pipe with a 1.0" to 2.1" OD.
RAD06
 
The RAD06 uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion. It also has lower self-heating in bright sunlight combined with higher temperatures (> 24°C (~75°F)) and low wind speeds (< 2m/s (~4.5 mph)), providing a better measurement.
 
28549 AP200 or CPEC200 AC/DC Power Adapter Kit
 
The 28549 can be mounted in the AP200 enclosure to supply the AP200 from AC mains power.
Power Cable Options
-NC -NC No Power Cable
-NAC -NAC North America Cable
-EUC -EUC Europe Cable
-UKC -UKC UK/Ireland Cable
-AUC -AUC Australia/NZ Cable
-CNC -CNC China Cable

Other Accessories

CR1000KD
 
The CR1000KD is offered as an accessory for customers who want the keyboard display but do not want it mounted inside the enclosure.
31021
 
The 31021 may be used as a source of zero air (air free of CO2 and H2O) for performing a field zero of the AP200 gas analyzer.

Replacement Parts

29998
 
The 29998 is a 2.5 cm diameter, Teflon filter with a 3 micron pore size. It is housed in plastic and has Luer Lock syringe fittings. The 29998 is used to replace dirty filters in the AP200 intakes that have become clogged. AP200 intakes shipped before August 2013 used a different filter and orifice; contact Campbell Scientific for replacement parts or intake upgrades.
29999
 
The 29999 orifice element is a replacement part for AP200 intake assemblies shipped in August 2013 or later.
4905
 
The 4905 Single 4-Unit Silica Desiccant Pack is packaged in Tyvek. It is used to desiccate the AP200 enclosure and will periodically need to be replaced.
28878
 
The 28878 is a replacement humidity indicator card. It provides a visual reference of humidity level inside the enclosure. Colored circles change color from blue to pink to indicate humidity levels of 30%, 40%, and 50% relative humidity.
33241
 
The 33241 is the drop-in replacement for the AP200 pump.