RETIRED ›
This product is no longer available.
083E-L
 
083E-L Met One Temperature/RH Sensor
 
083E-L Options - show details
-L ft cable per sensor

Allowed values: 0-1000 ft, increments of 1 ft

Campbell Scientific recommends:
  • 9 ft length—probe mounted to mast/leg at a 2 m height
  • 11 ft length—probe mounted to a CM202 at 2 m height
  • 11 ft length—probe mounted atop a CM6 via a CM202
  • 14 ft length—probe mounted atop a CM106, CM110, CM10, or UT10 via a CM202
  • 19 ft length—probe mounted atop a CM115 via a CM202
  • 24 ft length—probe mounted atop a UT20 via a CM202
  • 37 ft length—probe mounted atop a UT30 via a CM202
Add two feet to the cable length if you are mounting the enclosure on the leg base of a CM106, CM110, CM115, or CM120 tripod.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a prewired enclosure.
Product Details
Typically Ships Within 14 - 21 Days
Restockable Yes
Warranty 1 year
Compliance

The "Typically Ships Within" value is an estimate of the number of calendar days within which this product is ready to ship from Campbell Scientific. Orders with more than 10 built-to-order products will likely increase the time needed to prepare the order for shipping.

To estimate how long it will take to receive an order that contains multiple products, combine the longest Ships Within value with the transit time of the shipping method you select.

Some specialized products have long Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.


Common Accessories

41003-5
 
The 41003-5 provides a 10-plate naturally-aspirated radiation shield that houses one 083E probe. Its louvered construction allows air to pass freely through the shield thereby keeping the probe at or near ambient temperature. The 41003-5 attaches to a crossarm, mast, or user-supplied pipe with a 1.0" to 2.1" OD.
RAD14
 
The RAD14 uses a double-louvered design that offers improved sensor protection from driving rain, snow, and insect intrusion. It also has lower self-heating in bright sunlight combined with higher temperatures (> 24°C (~75°F)) and low wind speeds (< 2m/s (~4.5 mph)), providing a better measurement.

Replacement Parts

 
083ECBL-L 083E Replacement Cable
 
The 083ECBL connects the 083E sensor head with input and power terminals on the datalogger.
083ECBL-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Campbell Scientific recommends:
  • 9 ft length—probe mounted to mast/leg at a 2 m height
  • 11 ft length—probe mounted to a CM202 at 2 m height
  • 14 ft length—probe mounted atop a CM106B, CM110, or UT10 via a CM202
  • 19 ft length—probe mounted atop a CM115 via a CM202
  • 24 ft length—probe mounted atop a UT20 via a CM202
  • 37 ft length—probe mounted atop a UT30 via a CM202
Add two feet to the cable length if you are mounting the enclosure on the leg base of a CM106B, CM110, CM115, or CM120 tripod.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a prewired enclosure.
 
The 28430 is a 23.1 kohm precision resistor used with the 083E-L Temperature and Relative Humidity Sensor.
28415
 
The 28415 is the fitting used to mount a 083E-L Temperature and Relative Humidity Sensor in a 41003-5 Solar Radiation Shield.