03301-L
 
03301-L RM Young Wind Sentry Direction Sensor
 
03301-L Options - show details
-L ft cable per sensor

Allowed values: 0-1000 ft, increments of 1 ft

Custom lead lengths are available for up to 1000 feet. Campbell Scientific recommends:
  • 14 ft—sensor mounted atop a CM106B, CM110, or UT10 via a CM202
  • 19 ft—sensor mounted atop a CM115 via a CM202
  • 24 ft—sensor mounted atop a UT20 via a CM202
  • 37 ft—sensor mounted atop a UT30 via a CM202
Mounting - show details
-NM -NM No Mounting
Order the No Mounting Option if the 03301 will be replacing an existing 03301 within a Wind Sentry Set.
-P -PM Pipe Offset Mount
Order the -P option if the 03301 will be deployed on its own mount, and that mount will be next to an anemometer that already has its own mount. This pipe mount is also known as RM Young's model number 03145.
-SM -SM 03101 Conversion Kit
Order -SM option if the 03301 will be mounted next to a previously purchased 03101 Anemometer (Wind Sentry Anemometer). This conversion kit includes the crossarm and other hardware to mount both sensors to a common crossarm as if they had been purchased originally as a complete Wind Sentry Set.

Add to your Quote List


Product Details
Restockable Yes
Warranty 1 year
Compliance CE Compliance Image
Ships With
(1) 03301CBL-L Replacement Cable for Wind Sentry Vane
(1) Allen wrench from original mfg

Common Accessories

7623
 
The 7623 is an aluminum 0.75" IPS threaded pipe that has a 10" length. It is used with the pipe offset mount (-P option).

Replacement Parts

 
03301CBL-L 03001-L Replacement Wind Direction Sensor Cable
 
The 03301CBL-L consists of a 22 AWG cable with a Santoprene jacket and a connector for attachment to the vane. The 03301CBL can easily be replaced by the user.
Cable Length - show details
-L ft per sensor cable

Allowed values: 1-1000 ft, increments of 1 ft

Custom lead lengths are available for up to 1000 feet. Campbell Scientific recommends:
  • 14 ft—sensor mounted atop a CM106B, CM110, or UT10 via a CM202
  • 19 ft—sensor mounted atop a CM115 via a CM202
  • 24 ft—sensor mounted atop a UT20 via a CM202
  • 37 ft—sensor mounted atop a UT30 via a CM202
17962
 
The 17962 Mounting Conversion Kit should be ordered when the 03301 will be mounted next to a previously purchased 03101 Anemometer (Wind Sentry Wind Speed Sensor). It consists of the crossarm and other hardware to mount both sensors to a common crossarm as if they had been purchased originally as a complete Wind Sentry Set.
 
The 4913 should be ordered when the 03301 will be deployed on its own mount, next to an anemometer that's already on its own mount. This pipe mount is also known as RM Young model number 03145.
6700
 
Replacement of the 6700 potentiometer is fairly difficult to do. It requires the potentiometer to be soldered into place and then calibrated. Returning the sensor to the factory is recommended (an RMA is required).