014A-L
 
014A-L Met One Anemometer
 
014A-L Options - show details
-L ft cable per sensor

Allowed values: 0-1000 ft, increments of 1 ft

Custom lead lengths are available for up to 1000 feet. Campbell Scientific recommends:
  • 14 ft—sensor mounted atop a CM106B, CM110, or UT10 via a CM202
  • 19 ft—sensor mounted atop a CM115 via a CM202
  • 24 ft—sensor mounted atop a UT20 via a CM202
  • 37 ft—sensor mounted atop a UT30 via a CM202
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a prewired enclosure.

Add to your Quote List


Product Details
Restockable Yes
Warranty 1 year
Compliance CE Compliance Image
Ships With
(1) NIST Traceable Calibration Certificate & MIL-STD-45662A
(1) 014ACBL-L Replacement Cable for 014A Anemometer
(1) 5/64 in. Allen Wrench (from the manufacturer)

Common Accessories

1049
 
This NU-RAIL® Slip-on Offset Crossover fitting can be used in place of the CM220 to attach the sensor to the 1.0" IPS pipe of a crossarm.
CM220
 
The CM220 is used to mount the 014A to a CM200-series crossarm. It provides the same functionality as the 1049 NU-RAIL fitting.
CM216
 
The CM216 Sensor Mount provides a connection point for this sensor to be attached to the top of a CM106B, CM110, CM115, or CM120 Tripod.

Replacement Parts

 
014ACBL-L 014A-L Replacement Cable
 
The 014ACBL-L consists of a 22 AWG cable with a Santoprene jacket and a connector for attachment to the 014A Anemometer. This cable can easily be replaced by the user.
014ACBL-L Options - show details
-L ft per sensor cable

Allowed values: 1-1000 ft, increments of 1 ft

Custom lead lengths are available for up to 1000 feet. Campbell Scientific recommends:
  • 14 ft—sensor mounted atop a CM106B, CM110, or UT10 via a CM202
  • 19 ft—sensor mounted atop a CM115 via a CM202
  • 24 ft—sensor mounted atop a UT20 via a CM202
  • 37 ft—sensor mounted atop a UT30 via a CM202
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a prewired enclosure.
1184
 
The 1184 Reed Switch is difficult to replace without breaking it. Factory repair is recommended; request an RMA from Campbell Scientific.
16901
 
The 16901 turret label is easily replaced by the customer. This label serves to repel water and is placed over the small access hole in the turret to reduce ingress by water.
3648
 
Two of the 3648 bearings are required. They are difficult to replace without shattering the adjacent reed switch. Factory repair is recommended; request an RMA from Campbell Scientific. The bearings are also available from Met One as p/n A1898.