LI190R-L Quantum Sensor
Accurate, Versatile
Compatible with most Campbell Scientific dataloggers
weather applications water applications energy applications gas flux & turbulence applications infrastructure applications soil applications

Overview

The LI190R Quantum Sensor, manufactured by LI-COR, accurately measures photosynthetic photon flux density (PPFD), which is the number of photons in the 400 to 700 nm waveband incident per unit time on a unit surface. It uses a silicon photovoltaic detector mounted in a cosine-corrected head. A shunt resistor in the sensor’s cable converts the signal from microamps to millivolts, allowing these sensors to be measured directly by a Campbell Scientific datalogger.
.

Read More

Benefits and Features

  • Ideal for growth chambers and greenhouses
  • Measures photosynthetic photon flux density (PPFD) in both natural and artificial light
  • Compatible with the CWS900-series interfaces, allowing it to be used in a wireless sensor network

The "-L" on a product model indicates that the cable length is specified at the time of order.

Images

Mounted LI190R (items sold separately)
Mounted LI190R (items sold separately)
Mounted LI190R (items sold separately)
Mounted LI190R (items sold separately)

Detailed Description

The LI190R measures solar radiation with a silicon photovoltaic detector mounted in a cosine-corrected head. A shunt resistor in the sensor’s cable converts the signal from microamps to millivolts, allowing the LI190R to be measured directly by a Campbell Scientific datalogger. The LI190R accurately measures Photosynthetic Photon Flux Density (PPFD), which is the number of photons in the 400 to 700 nm waveband incident per unit time on a unit surface. Because PPFD describes photosynthetic activity, the LI190R is ideal for growth chambers and greenhouses. 

Specifications

Light Spectrum Waveband 400 to 700 nm
Calibration ±5% traceable to the U.S. National Institute of Standards Technology (NIST)
Sensitivity Range Typically 5 to 10 μA per 1000 μmoles s-1 m-2
Linearity Maximum deviation of 1% (up to 10,000 μmole s-1 m-2)
Shunt Resistor 604 Ω, 0.1%, 25 ppm
Long-Term Stability < ±2% change over a 1 year period
Response Time < 1 μs
Temperature Dependence 0.15% per °C (maximum)
Cosine Correction Cosine corrected up to 82° angle of incidence
Operating Temperature Range -40° to +65°C
Relative Humidity Range 0 to 100% (non-condensing)
Detector Description High-stability silicon photovoltaic (blue enhanced)
Sensor Housing Description Weatherproof anodized aluminum case with acrylic diffuser and stainless-steel hardware; O-ring seal on the removable base and cable assembly
Diameter 2.36 cm (0.93 in.)
Height 3.63 cm (1.43 in.)
Weight 84 g (2.96 oz)

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Dataloggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300
CR3000
CR310
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800
CR850
CR9000 (retired)
CR9000X

Additional Compatibility Information

Mounts

To ensure accurate measurements, the sensor should be leveled using an LI2003S leveling fixture, which incorporates a bubble level and three adjusting screws. The LI2003S leveling fixture mounts to a tripod using the 015ARM or to a crossarm using the CM225 mount. These sensors should be mounted away from all obstructions and reflective surfaces that might adversely affect the measurement.

Datalogger Considerations

The LI190R-L requires one differential analog input channel per probe.