RETIRED ›
This product is no longer available and has been replaced by: CS456,CS451. Some accessories, replacement parts, or services may still be available.
CS440-L ACData Sol'ns SPXD-500 4-20 mA Pressure Transducer

Overview

The CS440 submersible pressure transducer output a 4-20 mA signal to indicate observed pressure level. The CURS100 was typically used to convert the 4-20 mA signal to a millivolt signal. The datalogger then converted the millivolt signal to user-selected units (such as psi or feet). The static accuracy was ±0.1% over a 0° to 50°C temperature range.

Read More

The "-L" on a product model indicates that the cable length is specified at the time of order.

Images

Detailed Description

The CS440 was removed from our pricing system on August 22, 2008.

Specifications

Excitation 8 to 24 Vdc
Static Accuracy 0.1% span BFSL
Operating Temperature 0° to 60°C (non-freezing)
Diameter 2.5 cm (1.0 in.)
Cable Diameter 0.74 cm (0.29 in.)
Length 33.0 cm (13 in.)

Compatibility

Datalogger Considerations

The CS440 is measured with a single-ended datalogger instruction after converting the sensor signal from milliamps to millivolts using a 100 Ohm resistor.

Compatible Contemporary Dataloggers

CR200 Series CR800/CR850 CR1000 CR3000 CR5000 CR7X CR9000X

Compatible Retired Dataloggers

CR500 CR510 CR10 CR10X 21X CR23X CR9000