Spectrum
Spectrum
OrderableSpectral Analysis and High-Speed Analog Input Module
Pricing
Configuration
Sign in for option pricing- 3-ChannelSpectrum-103Part Number: 34877
- 9-ChannelSpectrum-109Part Number: 34879
Select a configuration to add to your quote
- Model:
- Spectrum
- Item Number:
- Spectrum
- Warranty:
- 1 year
Overview
The Spectrum Spectral Analysis and High-Speed Input Module—available in three-channel or nine-channel variants—offers high-speed synchronous sampling for analog inputs, with dedicated analog input hardware that includes amplifiers, filters, and analog-to-digital converters (ADC).
Key Advantages
High-Speed Dynamic Applications
Designed for analog measurements
Technical Description
The Spectrum 103 (three channels) and 109 (nine channels) share the same design, offering a variety of selectable input ranges on each channel.
Synchronization
Synchronization is achieved when all channels are sampled in coordination, based on a shared clock or timing signal.
Each channel is digitized using a 32-bit ADC and offer channel-to-channel sampling synchronization within approximately ±10 ns.
When using the EPI bus to synchronize across multiple modules, module-to-module synchronization is achieved within approximately ±100 ns.
Simultaneous
To achieve simultaneous measurements, where each channel is sampled at exactly the same time, each channel has its own dedicated ADC and processor. All channels begin their measurements at the same time and record over the same time interval—ensuring true time alignment across the board. Special hardware and processing is used to eliminate signal propagation delays and clock drift between modules.
Sample Rate
The Spectrum is capable of sustained high-speed measurements—up to 10,000 Hz per channel continuously. This is faster than any of our other products and allows for detailed insight into fast-changing signals.
When programming, select an anti-aliasing filter for sample rates up to 10 kHz and bandwidths up to 5 kHz.
Three-Axis
Each Spectrum channel offers selectable input ranges: ±200 mV, ±1 V, ±5 V, and ±10 V. The Spectrum 103 and 109, providing three or nine input channels respectively, make them ideal for three-axis accelerometers and strain gages.
Connection via EPI and CPI
Spectrum modules connect to data loggers via EPI or CPI networks using standard Ethernet cables (CAT5e, CAT6, or higher). EPI networks are ideal for Spectrum applications. For smaller channel count setups, a single Spectrum is connected to a traditional CPI-enabled data logger, such as the CR6.
Basic Programming
Short Cut software streamlines basic program creation for reading multiple Spectrum modules. It generates a wiring diagram and a CRBasic program for your data logger. For advanced processing or data management, you can further customize the CRBasic program.
Benefits
- Synchronization across multiple modules
- Simultaneous measurement across all channels
- Sustained high-speed measurements up to 10 kHz
- Ideal for three-axis accelerometers and strain gages
- Connection to data logger via EPI and CPI
- Streamlined creation of basic programs
Specifications
- Operating Temperature Range
- -40° to +70°C
- Storage Temperature
- -55° to +85°C
- IP Rating
- IP20
- Humidity
- 0 to 99%
(non-condensing)
- Number of Channels
- Three differential
(Spectrum 103)
Nine differential(Spectrum 109)
- Input Range
- ±10000 mV, ±5000 mV, ±1000 mV, and ±200 mV
- Common-Mode Input Voltage
- ±15 Vdc
- Absolute Maximum Input Voltage
- ±16 Vdc
- A/D Converters
- 32-bit SAR ADCs
- Measurement Accuracy @ 20°C
- ±(0.04% of reading ±130 μV)
Note: The accuracy specification does not include sensor error or measurement noise. - Input Resistance
- 80 MΩ
- Input Time Constant
- 230 ns
- Input Offset Current
- 5 nA typical, maximum @ 50°C
- Processor
- Digital signal processor 32-bit with floating point units
- Processor Speed
- 400 MHz
- Memory
- 128 MB SRAM
- Power Requirements
- 10 to 30 Vdc voltage
- Dimensions
- 21.6 x 13.7 x 7.6 cm (8.5 x 5.4 x 3.0 in.); additional clearance required for cables and wires
- Weight
- 1.6 kg
(3.53 lb)
Accessories
(8)35690
GRANITE Series DIN Rail Kit for 2 in. Modules
Orderable28899
CAT6 Ethernet Unshielded Cable with RJ45 Connectors, 2 ft
Orderable28900
CAT5e Ethernet Unshielded Cable with RJ45 Connectors, 10 ft
Orderable28901
CAT5e Ethernet Unshielded Cable, RJ45 to RJ45, 50 ft
Orderable8125
Flat-Bladed Screwdriver, 2.5 mm Blade x 50 mm Shaft
Orderable39177
1.67 A 24 Vdc Power Supply
OrderableDAQ Case 15
Data Acquisition (DAQ) Laboratory and Field Case
OrderableGranite Chassis
GRANITE Data Acquisition Systems Chassis
Orderable
Common Accessories
(6)35690
GRANITE Series DIN Rail Kit for 2 in. Modules
The 35690 can be purchased as an accessory to mount the 5.08 cm (2 in.) GRANITE™ modules on a DIN Rail instead of the standard backplate mounting.
Orderable28899
CAT6 Ethernet Unshielded Cable with RJ45 Connectors, 2 ft
The 28899 is a 2 ft, unshielded CAT6 network cable with RJ45 connectors. It is typically used to connect CDM devices together or to an SC-CPI. This cable is also used to connect one of our many Ethernet-capable products to an Ethernet device or network connection.
Orderable28900
CAT5e Ethernet Unshielded Cable with RJ45 Connectors, 10 ft
The 28900 is a 10 ft, unshielded, CAT5e network cable with RJ45 connectors. It is typically used to connect one of our many Ethernet-capable products to an Ethernet device or network connection.
Orderable28901
CAT5e Ethernet Unshielded Cable, RJ45 to RJ45, 50 ft
The 28901 is a 50 ft, unshielded, CAT5e cable with RJ45 connectors. It is typically used to connect CDM devices together or to a data logger. This cable can also be used to connect one of our many Ethernet-capable products to an Ethernet network connection.
Orderable8125
Flat-Bladed Screwdriver, 2.5 mm Blade x 50 mm Shaft
The 8125 is a small, flat-bladed screwdriver that is extremely useful for opening the guillotine terminals on our data loggers and measurement control devices. The blade is 2.5 mm across, and the untapered shaft length is 50 mm. The handle has an approximate length of 9 cm, and it features a rotating end-cap that makes the screwdriver easy to rotate.
Orderable39177
1.67 A 24 Vdc Power Supply
The 39177 converts 100 to 240 Vac to a regulated 24 Vdc. The 39177 comes standard with a USA/Canada plug, with an option to add a kit for international use. On one end, the 39177 has a plug that inserts into a wall socket. There are several cable termination options for the other end of the cable.
Orderable
Other Accessories
(2)DAQ Case 15
Data Acquisition (DAQ) Laboratory and Field Case
The DAQ Case 15 is a cost-effective and convenient carrying case for your valuable data acquisition equipment. This case is specifically configured for GRANITE™ Data Acquisition Systems and Campbell Scientific data loggers. The DAQ Case 15 is optimized for applications that require easy transport in a lab, in the field, or for short-term deployments.
OrderableGranite Chassis
GRANITE Data Acquisition Systems Chassis
The GRANITE™Chassis is a platform for housing a complete GRANITE system. The Chassis can hold up to eight modules, which may include the DAQ (Granite™10, Granite™9, or Granite™6), CH400, and additional GRANITE measurement modules. Portability and protection are fundamental to the design, delivering optimal system performance in demanding conditions—especially when heat must be dissipated quickly. Up to five panel faces (four top, one rear) can be customized to mount a wide variety of connectors, providing rapid connection to the DAQ system, which is ideal for time-sensitive or repetitive testing applications. As a GRANITE system scales to larger arrays of sensors and supporting GRANITE modules, several additional Chassis can be daisy-chained to expand the GRANITE DAQ network. With the optional 38822 Rackmount, Slide-Rail Kit, the Chassis can be easily mounted in a standard four-post server rack cabinet.
Orderable
Replacement Parts
(8)505
Screw #6-32 x .375 Pan Phillips
These screws, along with the 6044 grommets, are commonly used together to secure our equipment to the backplates of our enclosures.
Orderable6044
Grommet for #6 or #8 Screw
These grommets are commonly used with the 505 screws to secure our equipment to the backplates of our enclosures.
Orderable28490
Red Wire and Black Wire Power Cable Set
The 28490 includes two wires—one red and one black. These wires differ only in their insulation color; they have the same same length (1 ft) and gage (18 AWG). The red and black wires are used to connect a Campbell Scientific power supply to a data logger. The 28490 is shipped with our power supplies and may also be purchased as a replacement part.
Orderable28898
CAT6 Ethernet Unshielded Cable with RJ45 Connectors, 6 in.
The 28898 is a 6 in., unshielded, CAT6 network cable with RJ45 connectors. It is typically used to connect CDM devices together or to an SC-CPI. This cable is also used to connect one of our many Ethernet-capable products to an Ethernet device or network connection.
Orderable27555
USB 2.0 Cable, Type A Pin (Male) to Micro B Pin (Male), 6/6.5 ft
The 27555 is a USB Type A to Micro B, pin (male)-to-pin (male) cable, 6 to 6.5 ft long. It connects devices using the Micro B interface to a USB port on a computer.
Orderable29474
Stainless-Steel Screw #10-32 x .500 Slotted Set Cut Point
The 29474 is a ground lug with a slotted notch on its top that may be purchased to replace a lost or damaged ground lug.
Orderable34444
Terminal Connector Screw Plug Marked Spectrum
The 34444 is used with the Spectrum 103 and Spectrum 109 modules and may be ordered to replace a lost or damaged screw plug.
Orderable34614
GRANITE Replacement Power Connector
The 34614 is the four-position power connector that ships with the GRANITE™ data acquisition and measurement modules. It can be purchased as a replacement.
Orderable
Ships With
(15)505
Screw #6-32 x .375 Pan Phillips
OrderableQty 4505
Screw #6-32 x .375 Pan Phillips
OrderableQty 46044
Grommet for #6 or #8 Screw
OrderableQty 46044
Grommet for #6 or #8 Screw
OrderableQty 428490
Red Wire and Black Wire Power Cable Set
Orderable28490
Red Wire and Black Wire Power Cable Set
Orderable28898
CAT6 Ethernet Unshielded Cable with RJ45 Connectors, 6 in.
Orderable28898
CAT6 Ethernet Unshielded Cable with RJ45 Connectors, 6 in.
Orderable27555
USB 2.0 Cable, Type A Pin (Male) to Micro B Pin (Male), 6/6.5 ft
Orderable28899
CAT6 Ethernet Unshielded Cable with RJ45 Connectors, 2 ft
Orderable27555
USB 2.0 Cable, Type A Pin (Male) to Micro B Pin (Male), 6/6.5 ft
Orderable- Quick Deploy Guide (printed and folded)
- Quick Deploy Guide
- Calibration Sheet
- Calibration Sheet
Compatibility
Compatible Products
(4)Granite 9
High-Capacity, High-Speed Data Acquisition System
OrderableNotesThis preferred option requires OS version 1 or greater.
CR6
High-Capacity Data Acquisition System
OrderableNotesCompatibility is limited to a 1 kHz maximum and requires OS version 10 or greater. Limited to one Spectrum on the CPI channel for speeds less than 1,000 Hz.
Granite 10
Measurement and Control Data Acquisition System
OrderableNotesThis preferred option requires OS version 1 or greater.
CR1000Xe
Measurement and Control Datalogger
OrderableNotesCompatibility is limited to a 1 kHz maximum and requires OS version 4 or greater. Limited to one Spectrum on the CPI channel for speeds less than 1,000 Hz.
Related Resources
Documents
- Manual
Spectrum Series Product Manual
May 2026
View Document - Manual
Spectrum Series Product Manual (online)
December 2024
View Document - Compliance
Granite Spectrum UK Declaration of Conformity
April 2024
View Document - Compliance
Granite Spectrum EU Declaration of Conformity
April 2024
View Document
Showing 4 of 7 results
See all DocumentsDownloads
- Spectrum 100 Operating Systemv1.0.0Login required
May 9, 2025
OS and FirmwareCurrent Spectrum 100 Operating System.
- Spectrum Program Examplesv1Login required
December 22, 2025
Software ApplicationsThese example programs demonstrate the use of the CDM_VoltFilt(), CDM_BridgeFilt(), and CDM_FFTFilt() instructions with a Spectrum module. Additional examples include a program illustrating a mixed EPI/CPI network, a program demonstrating data streaming configuration using the FTPClient() instruction, and a program showing how to configure Spectrum modules using the CPIAddModule() instruction.