EC155
 
EC155 CO2/H2O Closed-Path Gas Analyzer System
 
Sensing Head Options
-GH -GH Gas Analyzer Only
-SH -SH CSAT3A & Gas Analyzer
-SH Sonic Carrying Case Opt
  -NC -NC No Sonic Case
  -SC -SC Sonic Carrying Case
 
Pressure Sensor Options - show details
-BB -BB Basic Barometer
Choose this option to get a barometer with a total accuracy of ±1.5 kPa (0° to +85°C).
-EB -EB Enhanced Barometer
Choose this option to get a barometer with a total accuracy of ±0.15 kPa (-40° to +60°C).
EC155 Carrying Case Opt
-NG -NG No EC155 Case
-GC -GC EC155 Carrying Case

Add to your Quote List


Product Details
Typically Ships Within 14 - 21 Days
Restockable Yes
Warranty 3 years or 17,500 hours
Compliance CE Compliance Image RoHS Compliance Image

The "Typically Ships Within" value is an estimate of the number of calendar days within which this product is ready to ship from Campbell Scientific. Orders with more than 10 built-to-order products will likely increase the time needed to prepare the order for shipping.

To estimate how long it will take to receive an order that contains multiple products, combine the longest Ships Within value with the transit time of the shipping method you select.

Some specialized products have long Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.

Ships With
(1) 26570 EC155 Mounting Platform
(1) EC155 Certificate of Conformance
(1) EC155 Packing Information Sheet
(1) CM250 Leveling Mounting Kit
(1) 26563 USB Data Cable, Type A Male to IP68 Panel Type Mini-B Male, 4.5 m
(1) 27008 EC155 Foam insert
(1) 4905 Desiccant 4-Unit Bag
(12) 2207 4 in. Nylon Cable Tie
(1) 8125 Flat-Bladed Screwdriver, 2.5 mm Blade x 50 mm Shaft
(2) 17492 Stainless-Steel U-Bolt Screw 5/16-18 x 2.125 with 2 Silicon Bronze Nuts

The EC155 is available only as a component of the CPEC200 Closed-Path Eddy-Covariance System.

Common Accessories

 
CABLEPCBL-L 2-Conductor 16AWG Power Cable
 
This 16-AWG, two-conductor cable with a Santoprene® jacket is used to power the EC155.
CABLEPCBL-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
 
CABLE4CBL-L 4-Conductor 22AWG Cable w/Drain
 
This 4-conductor, 22-AWG cable with drain wire and Santoprene jacket is used to attach the SDM connector on the EC155 electronics box.
CABLE4CBL-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
Choose this option if you are using this cable with a pre-wired enclosure.
 
CABLE2TP-L 2 Twisted Pair 22AWG Cable w/Drain
 
This two-twisted pair, 22-AWG cable with drain wire and Santoprene® jacket is used to attach the Analog Output connector on the EC155 electronics box.
CABLE2TP-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
Choose this option if you are using this cable with a prewired enclosure.
CABLE3TP-L
 
CABLE3TP-L 3 Twisted Pair 24AWG Cable w/Drain
 
The CABLE3TP-L is recommended for connecting the EC155 with an MD485 RS-485 multidrop interface (<500 ft). This three-twisted pair, 24-AWG cable has a Santoprene jacket and drain wire.
CABLE3TP-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector

Other Accessories

27114
 
This sonic anemometer head is similar to the sensor head from the CSAT3 sonic anemometer, but its cable is modified to connect to the EC100 electronics.
EasyFlux WebS
 
EasyFlux™ Web Self-Hosted is a web-based software tool for monitoring CR6- and CR3000-based Campbell Scientific, Inc. eddy-covariance systems. EasyFlux™ Web Self-Hosted is a user-installed version of EasyFlux™ Web that allows users the ability to install on their own server and control updates of the software themselves.

Replacement Parts

33384
 
The 33384 contains two desiccant/scrubber bottles utilizing a non-hazardous molecular sieve. Each bottle contains necessary chemicals and membrane filters for scrubbing CO2 and water vapor from the gas analyzer housing. Empty chemical bottles should be disposed of according to local and federal regulations. SDS (Safety Data Sheet) forms for the chemicals are included in the EC155 manual.
3768
 
The 3768 is the two-pin power connector fastened to the EC155. It can be purchased separately to replace a lost or damaged connector.
 
The EC100-EB includes the EC155 electronics box and a Campbell Scientific CS106 barometer mounted inside of the electronics box.
CM250
 
The CM250 is a leveling mount kit for attaching the EC155 to a crossarm.
 
The 26570 is required to mount the EC155 closed-path gas analyzer and the CSAT3A sonic anemometer head to a mounting structure.
4905
 
The 4905 Single 4-Unit Silica Desiccant Bag is packaged in Tyvek. The supplied desiccant should fill the initial needs of most applications, but should be periodically replaced.
17492
 
The 17492 provides a 5/16" U-bolt and two nuts. This product is used to mount solar panels, mounts, enclosures, or sensors to a mast, tower, or pole.
2207
 
The cable ties are constructed from a flexible, nylon material. A connection is made by pulling the tapered end through the locking end, thus forming a loop. The free end is pulled tight to secure the cables, then trimmed back to the locking end. Once attached, the cable tie must be cut to be removed.
 
The cable is 4.5 m long. It may be purchased to replace a lost or damaged cable.
8125
 
The 8125 is a small, flat-bladed screwdriver that is extremely useful for opening the guillotine terminals on our dataloggers and measurement control devices.
32203
 
The 32203 is a replacement in-line filter kit for the EC155 heated vortex. The kit includes a 25 µm filter and new ¼ in. Swagelok® nuts.
28698
 
The 28698 is a replacement intake filter (qty 1) and should be used for sites with excessive dust.
26072
 
The 26072 is a replacement intake filter (qty 1) and should be used for less dusty sites.
32127
 
The 32127 is a screen that prevents insects (such as mosquitoes or gnats) from entering the vortex intake of the EC155. This 1.27 cm (0.5 in.) diameter screen disc fits into the inlet of the vortex sample air cleaner. It is held in place with an interference fit and does not require adhesive or fasteners. It may be easily removed by using a needle or similar tool.
31461
 
The 31461 facilitates transporting the CSAT3A from site to site. The 31461 is offered as a replacement item for customers who do not have the foam that originally shipped with the CSAT3A.
33434
 
The 33434 is a carrying case without foam inserts that facilitates transporting the CSAT3A. The 33434 is intended for customers who already have foam inserts that were shipped with their CSAT3A.

Services

 
The 27332 provides a recalibration with zero and span. When drift between zero and span checks seems unstable, or when diagnostic output indicates a problem, the instrument should be sent in for a full factory calibration with zero and span. An RMA is required.
 
A zero and span should be done when ambient conditions change significantly (i.e., seasonally). An RMA is required.