v10.07Current NL241 firmware. Requires the Device Configuration Utility and a USB micro cable.
Revision History
- Minor1.The redpine WiFi module firmware version was updated to version 1.7.12.
v10.06October 7, 2020
Download unavailable
- Major1.NL241 now checks for an existing network with the same SSID before creating its network. If a network exists with the same SSID, the NL241 will not create its network.
- Minor2.When creating a network, the NL241 only use channels 1, 6, and 11 when the channel setting is set to Auto (default).
v10.05September 5, 2019
Download unavailable
- 1.Addresses a failure to connect issue if the device has not been communicated with in a while.
v10.03September 4, 2018
Download unavailable
- 1.Changed LED behavior in bridge mode when put in low power by the logger IPNetPower instruction - LED will be off.
- 2.Wi-Fi region now automatically set based on the information obtained from the Access Point.
- 3.Changed the data rate setting in the Wi-Fi module to AUTO when joining an Enterprise Security network.
- 4.Updated the Wi-Fi module firmware to version 1.6.9.1 (and associated API) which addresses the KRACK attack vulnerability.