Resource Center

Hydro-Link (Zip File)

Software applications, data logger operating systems, firmware, and drivers for Campbell Scientific products

Hydro-Link (Zip File)

v2.02.16

Hydro-Link is a browser-based user interface that can be run from a PC or directly from the datalogger. Currently this is only used on the CR300-series dataloggers.  Normally, when Hydro-Link is loaded onto and run directly from a CR300-series datalogger, the datalogger would have the Wi-Fi option or a CR310 with Ethernet.  When running Hydro-Link from the datalogger, smartphones and tablets can also be used to display the interface. 

Follow the Hydro-Link Installation Guide to install from the zip file.

Revision History

v2.02.16June 14, 2022
  • Minor
    Replace any NAN value in CV_Rain_Accum with zero on startup (ClimaVue)
  • Minor
    Don't append the current rain reading to CV_Rain_Accum when it is given as NAN (ClimaVue)
  • Minor
    Make it possible to edit Accumulated Precipitation (CV_Rain_Accum) from the dashboard (ClimaVue)
v2.02April 15, 2021
  • New Feature
    German version is now available.
  • New Feature
    Added Every 15th, 20th, 24th, 30th, and 60th for possible "Included Values" (decimation) selections in GOES configuration.
  • Minor
    Upgraded to CR3xx OS v10.04.
  • Minor
    The Configuration screen isn't accessible in the PC version when the station's configuration file was created by a different language version of HydroLink
  • Minor
    Fixed the PC version to collect Data in TOB1 and XML file format as well as TOA5.
  • Minor
    Fixed the Hourly Window Alarm - the alarm was previously not triggering properly between the hourly start time and hourly stop time.
  • Minor
    The TX325 interface is disabled if it was previously used but not currently in use.
  • Minor
    Any PPP configuration used previously by an external cell modem is removed when initializing GOES or Iridium communications.
  • Minor
    Improved SDI-12 address uniqueness checking.
  • Minor
    Improved message reporting for PakBus encryption login errors.
  • Minor
    Clarify that the datalogger clock synchronization triggered from the dashboard happens only once per trigger execution.
v2.01June 26, 2020
  • New Feature
    Added support for SoilVUE SDI-12 soil moisture sensor.
  • New Feature
    Added support for ClimaVUE complete weather sensor.
  • New Feature
    Added support for ARG314 tipping bucket rain gage.
  • New Feature
    Added support for LevelVUE B10 water level sensor.
  • New Feature
    Added support for the TX325.
  • New Feature
    Added ability to perform a system update from the Configuration page
  • Update tab.
  • Major
    Changes for compatibility with CR300 OS version 10.02.
  • Minor
    Added ability to reset TX325 to factory defaults.
  • Minor
    Added the ability set the Random Transit Interval to a minimum of 1 minute (TX325 only).
  • Minor
    Ability to trigger a random transmission for the TX325 and write the event to a log.
  • Minor
    Set a fixed clock synchronization time for the TX321 (daily, 12:05 PM).
  • Minor
    Added more diagnostic values to GOES_Status_Table.
  • Minor
    Improved ETo calculated value by allowing user to manually enter latitude/longitude/elevation.
  • Minor
    For ClimaVUE, ETo calculations can use GPS values when available (by entering 0 for latitude/longitude/elevation). Non-zero values should be used when GPS is not available or to override the GPS values.
  • Minor
    Changed ETo so that an ET calculation will not be performed if the measurement interval is greater than 1 hour.
  • Minor
    Barometric pressure for ClimaVUE is adjusted to sea level based on elevation.
  • Minor
    Added optional SDI-12 parameters for CS451, CS475A, and generic.
  • Minor
    Increased the maximum number of generic SDI-12 values returned from 9 to 15.
  • Minor
    Renamed the "PakBus/TCP Server Address" setting to "Datalogger/Router IP Address".
  • Minor
    When performing an update from previous Hydro-Link versions, configuration files will be copied from the CSI drive to the CPU drive.
  • Minor
    Added caution messages to inform users about incompatibility with older versions.
  • Minor
    Added a message to inform the user that changes cannot be made to the configuration when logged in as a Read Only user.
  • Minor
    Changed storage location of Settings.json and dash-config.json from CSI to CPU drive.
  • Minor
    Dashboard cosmetic changes.
  • Minor
    Added units and labels to all dashboard variable types.
  • Minor
    Added an "Enable All Outputs" option for sensors with more than four outputs.
  • Minor
    Changed the allowed variable name length to avoid compilation errors.
  • Minor
    Fixed a data type problem with the TCP Port value that could cause connection failures if the value was modified.
  • Minor
    Fixed a problem where the time displayed for the Next Scheduled Transmission could be a very large number.
  • Minor
    Made changes to avoid unknown SHEF code indicators in data.
  • Minor
    Added copyright information to support files.
  • Minor
    Updated desktop app to Electron version 7.1.2.

Connect With Us

phone icon
Phone Number
General: (435) 227-9000
location icon
Corporate Address
815 W 1800 N
Logan, UT 84321
send icon
Email Address
sales@campbellsci.com

As a trusted leader in measurement systems for more than 50 years, our top priority at Campbell Scientific has always been to provide the most accurate, reliable data for research and industry.