v2.02.16Hydro-Link is a browser-based user interface that can be run from a PC or directly from the datalogger. Currently this is only used on the CR300-series dataloggers. Normally, when Hydro-Link is loaded onto and run directly from a CR300-series datalogger, the datalogger would have the Wi-Fi option or a CR310 with Ethernet. When running Hydro-Link from the datalogger, smartphones and tablets can also be used to display the interface.
Revision History
- Minor1.Replace any NAN value in CV_Rain_Accum with zero on startup (ClimaVue)
- Minor2.Don't append the current rain reading to CV_Rain_Accum when it is given as NAN (ClimaVue)
- Minor3.Make it possible to edit Accumulated Precipitation (CV_Rain_Accum) from the dashboard (ClimaVue)
- New Feature1.German version is now available.
- New Feature2.Added Every 15th, 20th, 24th, 30th, and 60th for possible "Included Values" (decimation) selections in GOES configuration.
- Minor3.Upgraded to CR3xx OS v10.04.
- Minor4.The Configuration screen isn't accessible in the PC version when the station's configuration file was created by a different language version of HydroLink
- Minor5.Fixed the PC version to collect Data in TOB1 and XML file format as well as TOA5.
- Minor6.Fixed the Hourly Window Alarm - the alarm was previously not triggering properly between the hourly start time and hourly stop time.
- Minor7.The TX325 interface is disabled if it was previously used but not currently in use.
- Minor8.Any PPP configuration used previously by an external cell modem is removed when initializing GOES or Iridium communications.
- Minor9.Improved SDI-12 address uniqueness checking.
- Minor10.Improved message reporting for PakBus encryption login errors.
- Minor11.Clarify that the datalogger clock synchronization triggered from the dashboard happens only once per trigger execution.
v2.01June 26, 2020
Download unavailable
- New Feature1.Added support for SoilVUE SDI-12 soil moisture sensor.
- New Feature2.Added support for ClimaVUE complete weather sensor.
- New Feature3.Added support for ARG314 tipping bucket rain gage.
- New Feature4.Added support for LevelVUE B10 water level sensor.
- New Feature5.Added support for the TX325.
- New Feature6.Added ability to perform a system update from the Configuration page
- 7.Update tab.
- Major8.Changes for compatibility with CR300 OS version 10.02.
- Minor9.Added ability to reset TX325 to factory defaults.
- Minor10.Added the ability set the Random Transit Interval to a minimum of 1 minute (TX325 only).
- Minor11.Ability to trigger a random transmission for the TX325 and write the event to a log.
- Minor12.Set a fixed clock synchronization time for the TX321 (daily, 12:05 PM).
- Minor13.Added more diagnostic values to GOES_Status_Table.
- Minor14.Improved ETo calculated value by allowing user to manually enter latitude/longitude/elevation.
- Minor15.For ClimaVUE, ETo calculations can use GPS values when available (by entering 0 for latitude/longitude/elevation). Non-zero values should be used when GPS is not available or to override the GPS values.
- Minor16.Changed ETo so that an ET calculation will not be performed if the measurement interval is greater than 1 hour.
- Minor17.Barometric pressure for ClimaVUE is adjusted to sea level based on elevation.
- Minor18.Added optional SDI-12 parameters for CS451, CS475A, and generic.
- Minor19.Increased the maximum number of generic SDI-12 values returned from 9 to 15.
- Minor20.Renamed the "PakBus/TCP Server Address" setting to "Datalogger/Router IP Address".
- Minor21.When performing an update from previous Hydro-Link versions, configuration files will be copied from the CSI drive to the CPU drive.
- Minor22.Added caution messages to inform users about incompatibility with older versions.
- Minor23.Added a message to inform the user that changes cannot be made to the configuration when logged in as a Read Only user.
- Minor24.Changed storage location of Settings.json and dash-config.json from CSI to CPU drive.
- Minor25.Dashboard cosmetic changes.
- Minor26.Added units and labels to all dashboard variable types.
- Minor27.Added an "Enable All Outputs" option for sensors with more than four outputs.
- Minor28.Changed the allowed variable name length to avoid compilation errors.
- Minor29.Fixed a data type problem with the TCP Port value that could cause connection failures if the value was modified.
- Minor30.Fixed a problem where the time displayed for the Next Scheduled Transmission could be a very large number.
- Minor31.Made changes to avoid unknown SHEF code indicators in data.
- Minor32.Added copyright information to support files.
- Minor33.Updated desktop app to Electron version 7.1.2.