CH201
 
CH201 12V Charging Regulator (-40 to +60C)
 
Warranty Lengths
-SW -SW Standard 1yr Warranty
-XW -XW 4yr Warr Extension

Add to your Quote List


Product Details
Restockable Yes
Warranty 1 year
Compliance CE Compliance Image
Ships With
(4) 505 Screw #6-32 x .375 Pan Phillips
(4) 6044 Grommet for #6 or 8 Screw
(1) 28490 Red Wire and Black Wire Power Cable Set

Common Accessories

 
CABLE2CBL-L 2-Conductor 22AWG Cable w/Drain
 
The CABLE2CBL-L is used for SDI-12 or RS-232 communications. It connects the data logger to the communication ports on the CH201.
CABLE2CBL-L Options - show details
-L Pricing is in ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
Choose this option if you are using this cable with a pre-wired enclosure.
 
The 34029 is used to connect a 7 Ahr (BP7) battery to the CH201.
34031
 
The 34031 is used to connect a 12 or 24 AHr (BP12 or BP24) battery to the CH201.
34040
 
The 34040 connects a CH201 power supply to an auxiliary, 12 V flooded battery such as a deep-cycle marine or RV battery. This is helpful when the battery is not in the same enclosure as the charge regulator/controller. The cable length is 3.048 m (10 ft). This two-conductor cable has a two-pin connector on one end that attaches to the power supply, and pigtails on the other end that attach to the battery.
36589
 
The 36589 enables you to connect the BP84 84 Ah 12 V Sealed Rechargeable Battery to our CH charger regulators, such as the CH201.

Other Accessories

BP12
 
The BP12 is a rechargeable, 12 V, 12 Ah battery pack that can power a Campbell Scientific system that has components that have above-average power requirements, such as satellite transmitters.
BP24
 
The BP24 is a rechargeable 12 Vdc, 24 Ah battery pack that can power a Campbell Scientific system. It is intended for high-current-drain systems, such as satellite transmitters, that require more power.
BP84
 
BP84 12V Sealed Rechargeable Battery w/Mounts, 84Ah
 
The BP84 is a rechargeable 12 Vdc, 84 Ah battery pack that can power your system that has larger power requirements. It is typically used when access to ac power is not available.
Cable Options
-CC -CC w/cable to PS/CH Chrg
-GC -GC w/Generic Cable
SP10
 
SP10 10W Solar Panel, 20ft Cable
 
The SP10 is a 10-W photovoltaic power sources capable of recharging batteries. Its 6.1 m (20 ft) cable has stripped and tinned leads. The SP10 has a sufficient charging source for many of our system configurations in tropical to temperate latitudes. It allows unattended operation of systems in remote locations, far from AC electrical sources.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the data logger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a pre-wired enclosure.
-C -C w/ ET/CS110 Connector
With the -C option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station. This is equivalent to the -LC version available for some sensors.
Mounting Options - show details
-SM -SM Std Mounting Kit
Standard mounting to allow solar panel to be mounted directly to the leg of a tower or crossarm.
-EM -EM Extended Mounting Kit
Extended Mounting Kit allows the solar panel to be mounted on a tower or crossarm that puts the panel approximately 25.4 cm (10 in.) from the mast. This reduces shadows on the solar panel from other components or guy wires, which negatively affects the performance of the solar panel. It does, however, increase the wind load on the system.

To see an image of the 31108, visit the 31108 web page.
SP20
 
SP20 20W Solar Panel, 15ft Cable
 
The SP20 is a 20 W solar panel. It is often used for system configurations that have higher-than-average power requirements, or in higher elevation and latitude locations. It connects to Campbell Scientific power supplies and battery bases to recharge the battery, and it allows unattended operation of systems in remote locations that are far from ac electrical sources.
Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the data logger.
-PW -PW w/Pre-Wire Connector
With the -PW option, the cable terminates in a connector that attaches to a pre-wired enclosure.
Mounting Options - show details
-SM -SM Std Mounting Kit
Standard mounting to allow solar panel to be mounted directly to the leg of a tower or crossarm.
-EM -EM Extended Mounting Kit
Extended Mounting Kit allows the solar panel to be mounted on a tower or crossarm that puts the panel approximately 25.4 cm (10 in.) from the mast. This reduces shadows on the solar panel from other components or guy wires, which negatively affects the performance of the solar panel. It does, however, increase the wind load on the system.

To see an image of the 31108, visit the 31108 web page.
SP50-L
 
SP50-L 50W Solar Panel
 
The SP50-L 50 W solar panel is a photovoltaic power source capable of recharging batteries. It is used for systems that require 50 W solar panels. The SP50 allows unattended operation of systems in remote locations, far from ac electrical sources.
SP50-L Options - show details
-L Pricing is in ft cable per SP50

Allowed values: 1-50 ft, increments of 1 ft

A 20-ft length is typical; maximum length is 50 ft.
Cable Termination Options
-PT -PT w/Tinned Wires
-PW -PW w/Pre-Wire Connector
SP90-L
 
SP90-L 90W Solar Panel
 
The SP90-L 90 W solar panel is a photovoltaic power source capable of recharging batteries. It is used in systems that require high-power solar panels. The SP90 allows unattended operation of systems in remote locations, far from ac electrical sources.
SP90-L Options - show details
-L Pricing is in ft cable per SP90

Allowed values: 1-50 ft, increments of 1 ft

Cable Termination Options
-PT -PT w/Tinned Wires
-PW -PW w/Pre-Wire Connector

Replacement Parts

505
 
These screws, along with the 6044 grommets, are commonly used together to secure our equipment to the backplates of our enclosures.
6044
 
These grommets are commonly used with the 505 screws to secure our equipment to the backplates of our enclosures.
28490
 
The 28490 includes two wires—one red and one black. These wires differ only in their insulation color; they have the same same length (1 ft) and gage (18 AWG). The red and black wires are used to connect a Campbell Scientific power supply to a data logger.

Services

Campbell Scientific offers full repair services for this product. Contact us for an RMA (Returned Material Authorization).