Sections:
Common Accessories,
Replacement Parts
SR50A-L Pricing Details
Educational Discounts: Yes Quantity Discounts: Yes Restockable: Yes Warranty: 1 year
Educational Discounts: Yes Quantity Discounts: Yes Restockable: Yes Warranty: 1 year
| Model | Description | |||
| SR50A-L | CSC Sonic Ranging Sensor | |||
| SR50A-L Options (hide details) | ||||
| -L | ft cable per sensor | |||
|
Maximum cable length is 200 ft for the SDI-12 output, 200 ft for RS-232 output, and 984 ft for the RS-485 output.
|
||||
| Cable Termination Options (hide details) | ||||
| -PT | -PT w/Tinned Wires | |||
|
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
|
||||
| -PW | -PW w/Pre-Wire Connector | |||
|
With the -PW option, the cable terminates in a connector that attaches to a prewired enclosure.
|
||||
| Common Accessories | |
| 19517 | SR50A Mounting Kit |
|
This mounting kit can be used as an alternative to the 19484 mounting stem. The 19517 attaches directly to CM206 crossarm or a user-supplied horizontal pipe with a 1" to 1.75" OD.
|
|
| 19484 | SR50A Mounting Stem |
|
The 19484 mounting stem attaches to the sensor. The stem is then attached to the CM206 crossarm via a CM220 mount, 17953 NU-RAIL fitting, or CM230 Adjustable Inclination Mount.
|
|
| 17953 | 1 x 1 inch NURAIL Crossover Fitting |
|
The 17953 NU-RAIL Crossover Fitting can be used instead of the CM220 to attach the SR50A to a CM206 crossarm. The 19484 mounting stem is also required.
|
|
| CM220 | Right Angle Mounting Kit |
|
The CM220 Right-angle Mounting Bracket attaches this sensor to a CM206 crossarm. The 19484 mounting stem is also required.
|
|
| CM230 | Adjustable Angle Mounting Kit |
|
If the surface is at an angle, the CM230 Adjustable Inclination Mount can be used to position the SR50A so that it is perpendicular to the ground.
|
|
| CM230XL | Adjustable Angle Mounting Kit, Extended Length |
|
The CM230XL provides the same functionality as the CM230, but the CM230XL places the SR50A further from the pole or crossarm.
|
|
| Replacement Parts | ||||
| SR50ACBL-L | Replacement SR50A Cable | |||
|
This cable is available as a replacement item or as a "spare" cable. The SR50ACBL is fitted with a connector for attachment to the SR50A. On the other end, the cable terminates in pigtails for connection to the datalogger.
|
||||
| SR50ACBL-L Options | ||||
| -L | ft per sensor cable | |||
| Cable Termination Options | ||||
| -PT | -PT w/Tinned Wires | |||
| -PW | -PW w/Pre-Wire Connector | |||
| 19486 | SR50A Replacement Transducer Kit | |||
|
The 19486 provides one replacement transducer with connector, an O-ring, two #4091 desiccant bags, and two #905 desiccant bags. The transducer can typically be replaced in the field by the customer (assumes reasonably favorable weather conditions).
|
||||
| 905 | Desiccant 1/2 Unit Bag | |||
|
The 905 Single 0.5-Unit Desiccant Bag is a component of the 19486 transducer kit and is used to desiccate the inside of the SR50A.
|
||||
| 4091 | Desiccant 0.75g Bag | |||
|
Two of these 0.75 g desiccant bags help maintain a non-condensing environment inside of the instrument housing.
|
||||
Resources and Links
Related Documents
Ships With
(1) Test Report
(1) SR50ACBL-L Cable with user-specified length