Measurement and Control Products for WEATHER Measurement and Control Products for WATER Measurement and Control Products for ENERGY Measurement and Control Products for MACHINES Measurement and Control Products for STRUCTURES Measurement and Control Products for EARTH
Eases Programming
Simple way to generate datalogger programs

General Support

User Forum

Visit the Campbell Scientific Forum to submit your question to users around the world.

Ask an Expert

Ask a Question using our simple form and we'll pass it along to one of our experts.

Call Us

Our Application Engineers are ready to answer your questions. Our support numbers are:

Technical Support
US Sales
International Sales
Order Entry
Accounts Receivable
Repairs
435.227.9100
435.227.9120
435.227.9140
435.227.9090
435.227.9092
435.227.9105

Downloads

Short Cut v.2.9 (12.1 MB) Download Now

Short Cut creates simple programs for our CR200-series, CR510, CR500, CR10(X), 21X, CR23X, CR800, CR1000, CR3000, CR5000 and CR9000X dataloggers. Both mixed array and table data operating systems are supported. Short Cut also supports our ET106, ET107 and MetData1 weather stations. The newest version includes the latest sensor files.

FAQ

Q. What's new in SCWin 2.9?

Short Cut for Windows 2.9 includes the following enhancements from 2.8:

  • A new Datalogger step has been added to the Progress panel. In this step, you select the datalogger model and set the scan interval.  When generating a program for a CR9000X, the CR9000X Configuration box also appears on this screen.   
  • When adding a sensor, if more than one of the selected sensor can be added, the choice of how many sensors to add is included as part of the sensor’s form rather than as a separate dialog box.
  • When adding more than one sensor, a dialog box is available that allows you to input unique values for certain calibration and/or conversion factors (e.g., multiplier, offset, gage factor) for each sensor being measured.
  • Each sensor form now includes a wiring tab that shows the wiring for the sensor. This tab allows you to manually change the wiring location, if desired.
  • For some sensors that require an excitation voltage, the sensor form now includes parameters that allow you to calculate Sensors per Excitation Channel. (Exciting more than one sensor with an excitation channel is helpful when the sensors to be measured outnumber the available excitation channels.)
  • An SC115 CS I/O-to-USB Flash Memory Drive check box has been added to the Outputs screen. When this box is selected, new data will be copied to an SC115 when it is plugged into the CS I/O port of the datalogger.
  • Selected Sensors are now shown in a tree format and branches of the tree can be collapsed or expanded as desired. This can be especially useful when the Selected Sensor tree contains multiplexers.
  • New Sensor files:
        27106T Wind Speed Sensor
        CS525 ISFET pH Probe
        CS650/655 Water Content Reflectometer
        CS506 Fuel Moisture Sensor
        NR-LITE2 Net Radiometer
        CNR4 Net Radiometer
        Quarter Bridge Strain Gage
        Half Bridge Strain Gage
        Full Bridge Strain Gage
        Geokon 4000/4050 Vibrating Wire Strain Gage
        Geokon 4100 Series Vibrating Wire Strain Gage
        Geokon 4420 Vibrating Wire Crackmeter
        Geokon 4500 Series Vibrating Wire Piezometer
..more
Q. What's new in SCWin 2.8?

Short Cut for Windows version 2.8 includes two new sensor files:

  • CS450/CS455 Pressure Transducer
  • WindSonic4 (SDI12) Two-Dimensional Ultrasonic Wind Sensor
..more
Q. I can't find a manual for SCWin. Could you send one to me?

We do not offer an individual manual for SCWin. ShortCut information is provided in the LoggerNet, RTDAQ, and PC400 manuals. You can also obtain information from the Help screens within SCWin for assistance.

..more
Q. What's new in SCWin 2.7?

One of the biggest changes in Short Cut for Windows 2.7 is support for the ET107 Evapotranspiration Monitoring Station. Other changes include:

  • New sensor files:
    • 03002 Wind Speed and Direction Sensor
    • 105E (chromel-constantan) Thermocouple
    • AVW200 Two-Channel Vibrating Wire Spectrum Analyzer (vibrating wire sensors connected directly to the AVW200 or to one or two AM16/32 Multiplexers connected to the AVW200)
    • Vibrating Wire Sensor (for generic vibrating wire sensors and the AVW200)
    • WindSonic1 (RS-232) Two-Dimensional Ultrasonic Wind Sensor
    • HMP155 Temperature and Relative Humidity Sensor
    • SR50A Sonic Ranging Sensor (SDI-12 Output)
  • Removed the Add Device button. Peripheral devices are now listed in and selected directly from the Available Sensors and Devices tree.
  • Improved the readability of the wiring diagrams.
..more
Q. What's new in SCWin 2.6?

One of the biggest changes in Short Cut for Windows 2.6 is support for the CR900X Measurement and Control System. A selection of generic measurements and thermocouple sensors for the CR9000X are available for the first time in this release. Other changes include:

  • New sensor files for the CMP3 Pyranometer, the IRR-P Precision Infrared Temperature Sensor, the JC Ultrasonic Depth Sensor, the CNR2 Net Radiometer, the CS106 Barometric Pressure Sensor, the OBS-3+ Turbidity Sensor, and a saturation vapor pressure calculation
  • Advanced tab on the Finish screen for CRBasic datalogger, which allows you to view the CRBasic code and launch the CRBasic Editor
  • Option to send the program to the datalogger from the Results tab on the Finish screen
  • Ability to create custom sensors using existing sensor files as templates
  • Ability to manually set advanced outputs to high or low resolution
..more
Q. What's new in SCWin 2.5?
  1. User Interface: new, wizard-like user interface that makes the process of creating a datalogger program even easier than before.
  2. Dataloggers: support for the CR3000 Micrologger.
  3. Sensors:
    • Images to help you select the correct sensor for your program.
    • CSI sensor files for the CS15 Current Transformer and CS300 Apogee PYR-P Pyranometer.
  4. Wiring Diagrams: supports two additional colors (brown and orange) as well as the the ground symbol.
  5. User selectable print options (Results, Summary, Wiring Diagram, Wiring Text) added to the last step of creating your datalogger program.
  6. Improved Advanced Outputs:
    • “Ring” and “Fill and Stop” table options now supported.
    •  Added the ability to “Store Filemark” when a flag is toggled by the user.
    •  Added the option to set a flag high when a table becomes full.
    •  Added a “Data Event” output option.
..more
Q. What's new in SCWin 2.4?
  1. Added support for interfaces requiring special wiring between the datalogger and sensors:
    • LLAC4 4-channel Low-Level AC Conversion Module
    • SW12V Power Switch Assembly
  2. Added support for outputting data to the CR1000's compactflash module (CFM100).
  3. Added new CSI sensor files:
    • 107 Temperature Probe (4-wire version) for multiplexers
    • 108 Temperature Probe (3-wire) for multiplexers
    • 108 Temperature Probe (4-wire) for multiplexers
    • AGS Level Sensor (Metritape)
    • CNR1 Net Radiometer
    • CS100 Barometric Pressure Sensor
    • CS205-LC Fuel Temperature Sensor for the MetData1 and ET106
    • CS215 Temperature & Relative Humidity Sensor
    • CS505-LC Fuel Moisture Sensor for the MetData1 and ET106
    • CS512 Dissolved Oxygen Probe
    • HMP45C (6-wire) Temperature & Relative Humidity Sensor on the SW12V
    • NRG #200P Wind Direction Sensor
    • NRG #40 Wind Speed Sensor
    • Device for Analog Input from SDM-AO4
    • Device for Current/Voltage Input from SDM-CVO4
    • WindSonic-LC 2-D Sonic Wind Sensor for the MetData1
..more
Q. What's new in SCWin 2.3?
  1. We have merged the sensors list for our European office into SCWin, eliminating the need for two versions. If you are using our terminal input modules (TIMs), the wiring diagram in SCWin now supports them. Data storage to PCMCIA or CompactFlash cards has been added for the CR1000 and CR5000 dataloggers.
  2. Added support for alternative groups of sensor files, specifically to support sensor files developed for sensors specific to European users. The SCWin.EXE was modified to read new settings in the sensor files and display a menu item under the Settings menu to offer options for viewing Campbell Scientific Inc. or Campbell Scientific Ltd. sensor groups. 
  3. Added support for interfaces requiring special wiring between the datalogger and sensors: LLAC4 (4-channel device for reading low level AC signals on digital control ports), SW12V (standalone switched 12V relay cable for HMP45C sensors), Terminal Input Modules for the AGS Level Sensor and CNR1 Net Radiometer, A547 Interface for the CS547A Conductivity and Temperature Probe, QD1 Interface for quadrature shaft encoders, SDM-AO4 4-Channel Analog Output Module, and SDM-CVO4 4-Channel Current/Voltage Output Module. 
  4. Added support for outputting data to the CFM100 Compact Flash Module from the CR1000. 
  5. Added new sensor files: 
        107 Temperature Probe (4-wire version) for multiplexers
        108 Temperature Probe (3-wire) for multiplexers
        108 Temperature Probe (4-wire) for multiplexers
        AGS Level Sensor (Metritape)
        CNR1 Net Radiometer
        CS100 Barometric Pressure Sensor
        CS205-LC Fuel Temperature Sensor for the MetData1 and ET106
        CS215 Temperature & Relative Humidity Sensor
        CS505-LC Fuel Moisture Sensor for the MetData1 and ET106
        CS512 Dissolved Oxygen Probe
        HMP45C (6-wire) Temperature & Relative Humidity Sensor on the SW12V
        NRG #200P Wind Direction Sensor
        NRG #40 Wind Speed Sensor
        Device for Analog Input from SDM-AO4
        Device for Current/Voltage Input from SDM-CVO4
        WindSonic-LC 2-D Sonic Wind Sensor for the MetData1
        Wind Run Calculation
..more

Resources and Links

Related Documents

Home \ Products \ Software \ SCWin