Datalogger Considerations
Compatible Contemporary Dataloggers
| CR200(X) Series1 | CR800/CR8502 | CR10001 | CR30003 | CR5000 | CR7X | CR9000X |
![]() |
![]() |
![]() |
![]() |
![]() |
Notes:
1The CR200(X)-series and CR1000 dataloggers require PConnectCE version 2.0 or higher.
2The CR800 and CR850 require PConnectCE version 2.2 or higher.
3The CR3000 requires PConnectCE version 2.1 or higher.
Compatible Retired Dataloggers
| CR500 | CR5104 | CR10 | CR10X4 | 21X | CR23X4 | CR9000 |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Notes:
4For the CR510, CR10X, and CR23X, support for both the mixed-array and PakBus® datalogger operating systems is provided in PConnectCE version 2.0 or higher; prior versions only supported the mixed-array OS.
Datalogger Interfacing
- PDA-to-CS I/O connector or PDA-to-RS232 cable.
--OR--
- SC-IRDA Infrared Interface connects to the CS I/O port (not compatible w/CR200(X)-series)
PDA Requirements
- Operating system: Microsoft® Pocket PC or Windows Mobile®
- Must be capable of serial communication
- If using the SC-IRDA, the PDA must have an IRDA port and an IR chip set compatible with the SC-IRDA.
- For Bluetooth communication, the handheld must be Bluetooth enabled.
- Pocket PCs or Mobile Handhelds Tested by Campbell Scientific
Communication Requirements
PDA Connection for Serial Communication
PDA-to-serial cable or cradle (one end of the cable/cradle must terminate in a 9-pin serial connector) is required. The cable/cradle connects to the PDA-to-CS I/O connector or PDA-to-RS232 cable via the 9-pin serial connector. This cable/cradle may be included with the PDA, or it may need to be purchased as a separate accessory from the PDA manufacturer or a third party supplier.
Bluetooth Communication
Third-party Bluetooth serial adapter is required. The interface and/or cables that are used to connect the adapter to the datalogger will vary, depending upon whether the device acts like a DTE (computer) device or DCE (PDA) device. In some instances, this is evident by the pin-out of the adapter, but not always. A general rule is if the adapter has a 9-pin female connector, then the adapter is connected to the datalogger using the PDA-to-CS I/O connector for the CS I/O port or the PDA-to-RS232 cable for the RS-232 port. If the adapter has a 9-pin male connector, then the adapter is connected to the datalogger using an SC32B for the CS I/O port or it can be connected directly to the RS-232 port.
Software
- A compatible version of Microsoft ActiveSync® installed on the PC
- One copy of PConnectCE software per handheld
Computer
PConnectCE runs on Windows-based, 32-bit operating system (Windows 95, 98, ME, NT, or XP).
Resources and Links
Ships With
(1) PDA-to-CS I/O connector
(1) PDA-to-RS232 cable
Shipping Weights & Dims
1.0 lbs
454 g
Single Box Shipping Dimensions:
12" x 12" x 4"
30.5 x 30.5 x 10.2 cm



