EC150
 
EC150 CO2/H2O Open-Path Gas Analyzer System
 
Sensing Head Options - show details
-GH -GH Gas Analyzer Only
Choose this option to get an instrument that only measures absolute carbon dioxide and water vapor densities, air temperature, and barometric pressure.
-SH -SH CSAT3A & Gas Analyzer
-SH Sonic Carrying Case Opt
  -NC -NC No Sonic Case
  -SC -SC Sonic Carrying Case
 
Pressure Sensor Options - show details
-BB -BB Basic Barometer
Choose this option to get a barometer with a total accuracy of ±2.2 kPa (0° to +85°C).
-EB -EB Enhanced Barometer
Choose this option to get a barometer with a total accuracy of ±0.85 kPa (0° to +60°C).
EC150 Carrying Case Opt - show details
-NG -NG No EC150 Case
-GC -GC EC150 Carrying Case
The rigid carrying case holds the gas analyze.

Add to your Quote List


Product Details
Typically Ships Within 21 - 24 Days
Restockable Yes
Warranty 3 years or 17,500 hours
Compliance CE Compliance Image

The "Typically Ships Within" value is an estimate of the number of calendar days within which this product is ready to ship from Campbell Scientific. Orders with more than 10 built-to-order products will likely increase the time needed to prepare the order for shipping.

To estimate how long it will take to receive an order that contains multiple products, combine the longest Ships Within value with the transit time of the shipping method you select.

Some specialized products have long Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.

Ships With
(1) 26563 - USB Data Cable, Type A Male to IP68 Panel Type Mini-B Male
(1) EC150 Certificate of Conformance
(1) EC150 Packing Information Sheet
(1) 26520 - IRGASON and EC150 Replacement Temperature Probe
(1) 41303-5A - 6-Plate Solar Radiation Shield
(1) CM250 - Leveling Mounting Kit
(1) 4905 - Desiccant 4-Unit Bag
(1) 26787 - EC150 Case Foam Set
(1) 8125 - Flat-Bladed Screwdriver, 2.5 mm Blade x 50 mm Shaft
(12) 2207 - 4 in. Nylon Cable Tie
(2) 17492 - Stainless-Steel U-Bolt Screw 5/16-18 x 2.125 with Nuts
(2) 17446 - Stainless-Steel U-Bolt Screw 5/16-18 x 1.500 with Nuts

Common Accessories

 
CABLEPCBL-L 2-Conductor 16AWG Power Cable
 
This 16 AWG, two-conductor cable with a Santoprene jacket is used to power the EC150.
CABLEPCBL-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
 
CABLE4CBL-L 4-Conductor 22AWG Cable w/Drain
 
This 4-conductor, 22 AWG cable with drain wire and Santoprene jacket is used to attach the SDM connector on the EC150 electronics box.
CABLE4CBL-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
Choose this option if you are using this cable with a pre-wired enclosure.
26390
 
The 26390 is a zero and span shroud kit. A zero and span should be done when ambient conditions change significantly (i.e., seasonally).
31022
 
The Zero Air Generator is a low-cost, handheld source of zero air (air that has been scrubbed of CO2 and water vapor) to be used for zeroing infrared gas analyzers (IRGAs). The 31022 consists of a small pump and a molecular sieve. The pump is powered by 2 AA batteries.
27278
 
The 27278 is a lab stand kit for the EC150.
 
The 18442 provides a library of CRBasic programs used for a basic eddy covariance system.
 
The 18443 provides a library of CRBasic programs used for an extended eddy covariance system (with energy balance sensors).

Other Accessories

 
CABLE2TP-L 2 Twisted Pair 22AWG Cable w/Drain
 
This cable is needed to connect the Analog Output on the EC150 electronics box if using analog output rather than SDM. It is a two-twisted pair, 22 AWG cable with drain wire and Santoprene jacket.
CABLE2TP-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector
Choose this option if you are using this cable with a prewired enclosure.
CABLE3TP-L
 
CABLE3TP-L 3 Twisted Pair 24AWG Cable w/Drain
 
This cable is needed to connect the EC150 with an MD485 RS-485 multidrop interface if using RS-485 (<500 ft length) rather than SDM. It is a three-twisted pair, 24 AWG cable with drain wire and a Santoprene jacket.
CABLE3TP-L Options - show details
-L ft per cable

Allowed values: 1-1000 ft, increments of 1 ft

Cable Termination Options - show details
-PT -PT w/Tinned Wires
With the -PT option, the cable terminates in pigtails that connect directly to the datalogger.
-PW -PW w/Pre-Wire Connector

Replacement Parts

 
The 26510 is the chemical bottles assembly provided with the EC150. Two bottles are included.
28902
 
The sonic wick spares kit is used to replace wicks on a CSAT3, CSAT3A, or IRGASON. It includes three top wicks, three bottom wicks, an installation tool, and some adhesive.
26520
 
This special temperature probe is shipped with the EC150 and has a 10 ft cable.
4905
 
The 4905 Single 4-Unit Silica Desiccant Bag is used to desiccate the EC150's enclosure. It needs to be periodically replaced.
 
This wick can be placed on the bottom snout of the gas analyzer to help wick away rain droplets from the optical window. Recommended for sites with frequent rain.
 
This wick can be placed on the top snout of the gas analyzer to help wick away rain droplets from the optical window. Recommended for sites with frequent rain.
 
The EC100-EB includes the EC150 electronics box and a Campbell Scientific CS106 barometer mounted inside of the electronics box.
CM250
 
The CM250 is a leveling mount kit for attaching the EC150 to a crossarm.
 
The 27095 replaces a damaged EC150 carrying case and includes a foam insert. The carrying case may also be ordered as a separate item if it wasn't ordered initially with the EC150.
 
The cable is 4.5 m long. It may be purchased to replace a lost or damaged cable.
2207
 
The cable ties are constructed from a flexible, nylon material. A connection is made by pulling the tapered end through the locking end, thus forming a loop. The free end is pulled tight to secure the cables, then trimmed back to the locking end. Once attached, the cable tie must be cut to be removed.
17446
 
The 17446 provides a U-bolt and two nuts as a replacement for the original U-bolt and nuts.
17492
 
The 17492 provides a 5/16" U-bolt and two nuts. This product is used to mount solar panels, mounts, enclosures, or sensors to a mast, tower, or pole.
8125
 
The 8125 is a small, flat-bladed screwdriver that is extremely useful for opening the guillotine terminals on our dataloggers and measurement control devices.

Services

 
The 27311 provides a recalibration with zero and span. When drift between zero and span checks seems unstable, or when diagnostic output indicates a problem, the instrument should be sent in for a full factory calibration with zero and span. An RMA is required.
 
A zero and span should be done when ambient conditions change significantly (i.e., seasonally). If the user does not have a zero/span kit to do this himself/herself, it can be sent in to Campbell Scientific. An RMA is required.