CR1000
 
CR1000 Measurement & Control Datalogger
 
Temperature Ranges - show details
-ST -ST -25 to +50C
Every CR1000 is tested and guaranteed to perform within published specifications over the standard temperature range. Units are tested and shipped to the standard temperature range unless an extended range is specified. Any internal batteries are not tested or guaranteed across the entire standard temperature range.
-XT -XT -55 to +85C
When ordered, the CR1000 is tested and guaranteed to perform over the extended temperature range. Analog accuracies are derated approximately two times over the published specifications. The extended testing covers the -55° to +85°C range. Any internal batteries are not tested or guaranteed across the entire extended temperature range.
Warranty Lengths - show details
-SW -SW Standard 3yr Warranty
At the time of purchase, the CR1000 includes a standard warranty of 36 months. See our full warranty policy in the CR1000 manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our Extended Warranty adds 48 months to the standard 36 month warranty, bringing the total warranty period to 84 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
Calibration Certificate - show details
-NC -NC No Calibration Cert
The CR1000 is shipped without a calibration certificate.
-CC -CC Calibration Cert
When this option is chosen, a two-page calibration certificate is shipped with the datalogger. If you are using the 21852 A2LA/NVLAP Calibration Service, you do not need to order this option because Simco will send you a calibration certificate. (See the description of the 21852 service.)

Add to your Quote List


Product Details
Typically Ships Within 2 - 5 Days
Restockable Yes
Warranty 3 years
Compliance CE Compliance Image RoHS Compliance Image

The "Typically Ships Within" value is an estimate of the number of calendar days within which this product is ready to ship from Campbell Scientific. Orders with more than 10 built-to-order products will likely increase the time needed to prepare the order for shipping.

To estimate how long it will take to receive an order that contains multiple products, combine the longest Ships Within value with the transit time of the shipping method you select.

Some specialized products have long Ships Within values. Because of this, you might consider submitting a separate order for these products so your other products won't be delayed.

Ships With
(4) 505 - Screw #6-32 x .375 Pan Phillips
(1) 1113 - Flat-Bladed Screwdriver, 3 mm Blade x 60 mm Shaft
(1) 8125 - Flat-Bladed Screwdriver, 2.5 mm Blade x 50 mm Shaft
(4) 6044 - Grommet for #6 or 8 Screw
(1) 10873 - Serial Data Cable, 9-Pin Female to 9-Pin Male
(1) Default datalogger program [#17598]
(1) 3315 - Type T Thermocouple

Common Accessories

SC32B
 
SC32B: Recommend 1 of 2 for Communication to AC Powered PC
SC-USB
 
SC-USB: Recommend 1 of 2 for Communication to AC Powered PC
SC-CPI
 
SC-CPI Datalogger Serial to CPI Interface
 
Will need if using CDMs
Temperature Ranges - show details
-ST -ST -25 to +50C
Every SC-CPI is tested and guaranteed to perform within published specifications over the standard temperature range.Units are tested and shipped to standard operating range unless extended testing is specified.
-XT -XT -55 to +85C
Extended temperature testing over the -55° to +85°C range is also available. Individual units are subjected to performance tests at these extremes in a test chamber. Units that pass the tests are certified as extended temperature units.
Warranty Lengths - show details
-SW -SW Standard 1yr Warranty
At the time of purchase, the SC-CPI includes a standard warranty of 12 months. See our full warranty policy in the SC-CP manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our extended warranty adds 48 months to the standard 12 month warranty, bringing the total warranty period to 60 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.

Replacement Parts

 
CR1000WP Wiring Panel
 
The CR1000WP provides a black, anodized aluminum wiring panel with "CR1000WP" labeled in white. It may be purchased to replace a lost or damaged wiring panel. A complete CR1000 datalogger requires the CR1000WP to be connected to a CR1000M module.
Warranty Lengths - show details
-SW -SW Standard 3yr Warranty
At the time of purchase, the CR1000WP includes a standard warranty of 36 months. See our full warranty policy in the CR1000 manual for the terms and conditions of this warranty.
-XW -XW 4yr Warr Extension
Our Extended Warranty adds 48 months to the standard 36 month warranty, bringing the total warranty period to 84 months. The extended warranty may be purchased only at the time of original product purchase. It may NOT be "added later." Except for the increased coverage length, the same terms and conditions apply to the extended warranty as apply to the standard warranty.
 
The 17315 protects the peripheral port and may be purchased to replace a lost or damaged cover.
10645
 
The 10645 is the screw used in the ground lug.
1113
 
The 1113 Flat-bladed screwdriver is used to attach sensor leads to the wiring panel's screw terminals.
13519
 
The 13519 fits inside of the CR1000 module. This lithium battery powers the clock and SRAM when the primary 12 Vdc power supply is not connected. The 13519 can be replaced by the user; the process is illustrated in the CR1000 Operator's Manual.
3768
 
The 3768 is shipped attached to the CR1000. This green, plug-in power connector provides screw terminals for connecting the 12 V and GND wires of the datalogger's power supply. The 3768 may be purchased to replace a lost or damaged power connector.
6554
 
This desiccant pack fits inside of the CR1000 module. The 6554 is generally replaced when the internal lithium battery is replaced.
 
The 17746 is offered for customers who want a paper CR1000 Operators Manual. This manual comes in a 3-ring binder. The price listed is for paper manuals ordered without the datalogger. Paper manuals ordered on the same purchase order as the datalogger are available at no extra charge. However, the customer must indicate that they want a paper manual. Otherwise, they will receive a ResourceDVD containing a PDF version of the manual.
8125
 
The 8125 is a small, flat-bladed screwdriver that is extremely useful for opening the guillotine terminals on our dataloggers and measurement control devices.
10873
 
The 10873 is a serial cable that is useful for connecting the RS-232 port of the datalogger to the 9-pin RS-232 port of a computer. The cable is six feet long.
3315
 
This type T, 5 in. thermocouple is attached to a differential channel on several of our datalogger wiring panels when the datalogger is shipped. A 3315 may be ordered to replace a thermocouple that has become lost or damaged.
505
 
These screws, along with the 6044 grommets, are commonly used together to secure our equipment to the backplates of our enclosures.
6044
 
These grommets are commonly used with the 505 screws to secure our equipment to the backplates of our enclosures.

Services

 
The 17749 requires an RMA (Returned Material Authorization) from Campbell Scientific. When ordered, we recalibrate the CR1000 to meet original specifications. Recalibration includes standard temperature testing (-25° to +50°C). Before and after calibration sheets are supplied with the CR1000.
 
The 16131 orders the two-page calibration certificate. If you are using the 21852 A2LA/NVLAP Calibration Service, you do not need to order this because Simco will send you a calibration certificate. (See the description of the 21852 service.)
 
Retesting is available only for individual units that have previously passed Extended Temperature Testing. Retesting also requires concurrent purchase of recalibration. An RMA (Returned Material Authorization) from Campbell Scientific is required.
 
If you have a large group of individuals who require standard or custom training, it may be cost-effective for us to come to you. This class includes 4 days of training on the CR1000 and LoggerNet. One Applications Engineer conducts the training (5 people maximum). Our travel expenses within the continental United States are included, as are use of dataloggers, computers, software, sensors, and instructional materials. Our training materials are shipped in cases that contain 3 training set-ups per case; we have four cases available for training.
 
This class includes 4 days of training on the CR1000 and LoggerNet. Two Applications Engineers conduct the training (11 people maximum). Our travel expenses within the continental United States are included, as are use of dataloggers, computers, software, sensors, and instructional materials. Our training materials are shipped in cases that contain 3 training set-ups per case; we have four cases available for training.
 
We offer training courses at our factory in Logan, Utah. Price includes 4 days of instruction on the CR1000 Datalogger and LoggerNet software, and allows the use of training computers, dataloggers, and facilities. Travel and accommodations are NOT included. Lunch will be provided by CSI on each day of class.