CPEC306
CPEC306
OrderableExpandable Closed-Path Eddy-Covariance System with EC155 and Pump Module
Pricing
Configuration
Sign in for option pricing- w/EC155 & Pump Module (-30 to +50C) w/CR6-NA w/VOLT116 w/Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) w/CR6-NA w/VOLT116 No Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) w/CR6-NA w/o VOLT116 w/Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) w/CR6-NA w/o VOLT116 No Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) Wired for CR6 w/VOLT116 w/Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) Wired for CR6 w/VOLT116 No Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) Wired for CR6 w/o VOLT116 w/Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) Wired for CR6 w/o VOLT116 No Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- 5 & Pump Module (-30 to +50C) w/CR6-WIFI w/VOLT116 w/Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Case5
- 5 & Pump Module (-30 to +50C) w/CR6-WIFI w/VOLT116 No Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Case5
Select a configuration to add to your quote
- Model:
- CPEC306
- Item Number:
- 45298
- Warranty:
- 1 year
Overview
The CPEC306 with EasyFlux® is a turn-key, closed-path eddy-covariance (EC) flux system for long-term monitoring of atmospheric-biosphere exchanges of carbon dioxide, water vapor, heat, and momentum. A complete system consists of a closed-path gas analyzer (EC155 closed-path gas analyzer), sonic anemometer (CSAT3A sonic anemometer), data logger (CR6 datalogger), sample pump, and accommodations for a Granite™ Volt 116 allowing for additional sensors.
The gas analyzer’s intake design and small sample cell volume (5.9 mL) provide excellent frequency response (4.3 Hz cutoff frequency) with low total system power (12 W). Additionally, the vortex intake (United States Patent No. 9,217,692) greatly reduces maintenance and maintains frequency response compared to traditional inline filters.
Key Advantages
Provides additional ports without automatic zero and span
Technical Description
The gas analyzer’s small sample cell volume (5.9 mL) minimizes the sample residence time (50 ms at the system’s nominal flow rate, 7 LPM). This gives excellent frequency response (5.8 Hz half-power bandwidth) with low total system power (12 W).
Eddy-Covariance Measurements
CO2 and H2O are measured with an EC155 Closed-Path Gas Analyzer. Three-dimensional wind speed and sonic air temperature are measured with a CSAT3A sonic anemometer head.
CPEC306 System Enclosure
The CPEC306 has two enclosures: a fiberglass enclosure that houses the CR6 datalogger, pump module, and optional Granite Volt 116, and the EC100 enclosure for data processing.
CPEC306 Pump Module
The pump module, a standard component of the CPEC306 system, consists of a small dual-head diaphragm pump with a brushless dc motor mounted inside a fiberglass enclosure. An integral cable connects the pump module to the CPEC306 system enclosure, which provides power, temperature measurement and control, pressure measurement, and pumping speed measurement and control.
Benefits
- New conformal coating helps protect sonic transducers in corrosive environments
- Expandable, mid-level system with CR6 datalogger processing power
- Suitable for sites with many sensors and either a short or tall tower
- Simple design for easier troubleshooting
Specifications
- Operating Temperature Range
- -30° to +50°C
- Input Voltage Range
- 10.5 to 16.0 Vdc
- Power
- 12 W
(typical)
35 W(maximum, at cold startup)
System Enclosure
- Dimensions
- 54 x 44.5 x 29.7 cm
(21.3 x 17.5 x 11.7 in.)
- Weight
- 13.72 kg
(30.25 lb)
14.6 kg(32.2 lb) with optional Granite Volt 116 module
Pump Module
- Inlet Connection
- 3/8-in. Swagelok
- Pressure Sensor Range
- 15 to 115 kPa
- Pumping Speed
- 3 to 9 LPM
(automatically controlled at the set point, typically 8 LPM)
Accessories
(10)CABLEPCBL
2-Conductor 16 AWG Power Cable
OrderableCABLE4CBL
4-Conductor 22 AWG Cable with Drain
Orderable45309
CPEC200/300 Pump Tubing Assembly, 0.375 OD
Orderable21823
Calibration Gas Tubing Assembly
OrderableEasyFlux DL
Eddy-Covariance Data Logger Program
Orderable38476
16 GB microSD Flash aMLC Memory Card
Orderable27158
2 GB microSD Flash SLC Memory Card
Orderable45308
CPEC200/300 Pump Tubing Assembly, 0.500 OD
OrderableEasyFlux PC
Eddy-Covariance Post-Processing PC Software
OrderableFluoreSens 10
Sun-Induced Chlorophyll Fluorescence (SIF) System
Orderable
Need Something Not Listed?
(45298)Don't see what you need from among these options? Download the complete configuration list below.
View all product configurationsRelated Resources
Documents
- Compliance
CPEC306 and CPEC310 with CR6-RF422 EU Declaration of Conformity
February 2018
View Document - Manual
CPEC306 Quick Deploy Guide
September 2018
View Document - Document
Using Molecular Sieve to Zero Infrared Gas Analyzers for Eddy Covariance or Atmospheric Profile Measurements
View Document - Manual
EC155 Packing Information
November 2018
View Document
Showing 4 of 22 results
See all DocumentsDownloads
- CR6 OSv14.5.1Login required
April 17, 2026
OS and FirmwareThis download is for the CR6 datalogger. Execution of this download places the current CR6 Operating System file(.obj) and WiFi, RF45x and RF4xx operating systems (iobj) on your computer. It also updates the CRBasic Editor compiler and support files. Why Update? New features and bug fixes. With this OS update it is recommended that you also update the Device Configuration Utility to the most recent version so that new datalogger features are available in the utility. Note: Campbell Scientific always recommends updating operating systems on site if possible. When remote updates are required, it is recommended that you implement the necessary precautions to handle unexpected OS upload complications. All datalogger settings should be retained when updated remotely. If you choose to roll back to a previous operating system, the datalogger settings will be reset to default. Watch the Video Tutorial: Sending an OS to a Local Datalogger.
- EC100 OSv8.02Login required
October 14, 2019
OS and FirmwareEC100 Operating System. Watch the Video Tutorial: Updating the EC100 Operating System.
- ECMonv1.6Login required
March 29, 2016
Software ApplicationsEC100-Series Support Software.
- Device Configuration Utilityv2.35.02Login required
June 22, 2026
Software ApplicationsA software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package. Supported Operating Systems: Windows 11 or 10 (Both 32 and 64 bit)
Showing 4 of 6 results
See all Downloads