AeroX Light
AeroX Light
Status unavailableRunway Light Intensity Monitor (RLIM)
Pricing
Configuration
Sign in for option pricing- w/CH150 & 12Ahr BatteryAeroXLight-P1Part Number: 40804
- w/CH201 & 12Ah BatteryAeroXLight-P2Part Number: 40805
Select a configuration to add to your quote
- Model:
- AeroX Light
- Item Number:
- AeroXLight
- Warranty:
- 1 year
Overview
The AeroX™Light is a runway light intensity monitor (RLIM) designed specifically for Campbell Scientific automated weather observing systems (AWOS). The AeroX Light can monitor up to four runways that have two lighting loops per runway. Airports with more runways require additional AeroX Light RLIMs.
The AeroX Light consists of an enclosure that houses a CR1000Xe Measurement and Control Datalogger, AC power protection devices, and a power supply. Campbell Scientific offers power options to handle voltages up to 260 Vac and provide battery backup.
Learn more about our CampbellAero™ Automated Weather Observing System (AWOS) Solution and our CampbellAero Software.
Key Advantages
Monitors up to four runways
Technical Description
The AeroX Light determines runway light intensity by measuring the current in the lighting loop using clamp-on current transducers. Each current transducer outputs 4 to 20 mA of current proportional to the amount of current in the lighting loop. Typically, edge and center lighting loops are on each airport runway. The lights can be LED or incandescent. Designed to integrate seamlessly with CampbellAero software, the AeroX Light monitors the current and sends the calibrated current data to the CampbellAero server for interpretation. The CampbellAero server polls the AeroX Light when the data is required.
Benefits
- Capable of monitoring edge and center lighting loops of four runways for a total of eight lighting loops
- Reports battery voltage and errors such as AC power failure, protection circuit fault, and low battery
- Controlled by clamp-on, current-calibration software
- TCP/IP communications with CampbellAero™ server
- Lockable, poly-fiber enclosure
Specifications
- Light Monitored
- LED
(up to 6.6 A)
Incandescent(up to 20 A)
- AC Input Range
- 85 to 264 Vac
- Short-term Input Voltage
- 300 Vac
- Maximum AC Input Current
- 2 A
- AC Frequency Range
- 45 to 65 Hz
- Inrush Surge Current
- < 15 A
(typical)
- Backup Battery
- Maintains power to RLIM for a minimum of four hours.
- Operating Temperature Range
- -40 to +85°C
- Mean Time Between Failure (MTBF)
- > 500,000 h in accordance with IEC 61709
(SN 29500)
- Transient Protection
- Pluggable, no-fuse, fail-safe surge-suppression device
- Compliance Information
- All components meet UL, CE, and CSA power safety requirements.
- Case Dimensions
- 46 x 51 x 30 cm
(18 x 20 x 12 in.)
- Weight
- 14 kg
(30 lb)
Replacement Parts
(5)39167
AC Line Filter, Single-Phase DIN Rail Mount
The 39167 is a double-stage, single-phase filter and is DIN rail mountable. This filter provides protection against interference voltage from the mains power, as well as providing overcurrent and over voltage protection to the system.
Orderable39201
Replacement Surge Protection Plug for 120 Vac Systems
The 39201 is a UL-recognized type 1 and IEC type 2 surge protection plug with a varistor and thermal disconnect. This plug is used with the Phoenix Contact VAL base elements as the L-N replacement plug for 120 Vac systems. The plug has a mechanical and visual fault warning.
Orderable39202
Replacement Surge Protection Plug for 240 Vac Systems
The 39202 is a UL-recognized type 1 and IEC type 2 surge protection plug with a varistor and thermal disconnect. This plug is used with the Phoenix Contact VAL base elements as the L-N replacement plug for 240 Vac systems. The plug has a mechanical and visual fault warning.
Orderable39203
Replacement Surge Protection Plug for 120 or 240 Vac Systems
The 39203 is a UL-recognized type 1 and IEC type 2 surge protection plug with a gas discharge tube and thermal disconnect. This plug is used with the Phoenix Contact VAL base elements as the N-PE replacement plug for both 120 and 240 Vac systems. The plug has a mechanical and visual fault warning.
Orderable6053
12 V Lead-Acid Battery with Bare Terminals
The 6053 provides only a 12 Vdc, 7 Ahr sealed rechargeable battery—connectors and enclosure mounting hardware are not included. The 6053 is a component of the 17365 rechargeable power supply for several products including the CR6, CR300, CR310, CRVW3, CRVW3-NE, CR200-series dataloggers, and CR200X-series dataloggers. The 6053 is available as a replacement item.
Orderable
Ships With
(2)- Calibration Sheet Passive Clamp-On Current Sensors Conducted with FAT
- Calibration Sheet Passive Clamp-On Current Sensors Conducted with FAT