41003-5
41003-5
Orderable10-Plate Solar Radiation Shield
Overview
The 41003-5, manufactured by R. M. Young, is a naturally aspirated 10-plate radiation shield. Its louvered construction allows air to pass freely through the shield, keeping the probe at or near ambient temperature. The shield's white color reflects solar radiation.
Key Advantages
Shades and protects sensor
Technical Description
The 41003-5 10-Plate Solar Radiation Shield houses the HC2S3 or EE181-L Temperature and RH probe.
The 41003-5 can also house a 43347, 107, 108, 109, or HMP60 probe. The HMP45C and several other retired sensors are also compatible. Refer to the Compatibility section for the hardware required to mount the above sensors in the shield.
The 41003-5 includes a 2 in. U-bolt with a plastic v-block. The U-bolt is placed in the holes on the side of the bracket for attachment to a mast or vertical pole. The U-bolt is placed in the holes on the bottom of the bracket for attachment to a crossarm.
The 41003-5 10-plate Radiation Shield replaced the 41002 12-Plate Gill Radiation Shield in June of 2005. The biggest improvement of the 41003-5 is that it can be mounted to either a vertical pole or horizontal pipe. The retired 41002 only mounted to a vertical pole.
Benefits
- Naturally shades and protects the sensor
Specifications
- Construction
- UV-stabilized white thermoplastic plates, aluminum mounting bracket, white powder-coated stainless-steel U-bolt clamp
- Plate Diameter
- 11.9 cm
(4.7 in.)
- Height
- 20.3 cm
(8.0 in.)
- Weight
- 590 g
(1.3 lb)
Other Accessories
(5)27731
Solar Radiation Shield Hex Plug for for Mounting the HC2S3 inside the 41003-5
The 27731 hex plug is required to mount the HC2S3 temperature and relative humidity sensor in the 41003-5.
Orderable15823
Hex Plug for HMP45C or EE181
The 15823 hex plug is required to mount the HMP45C temperature and relative humidity sensor in the 41003-5.
Orderable27251
Hex Plug for 43347
This hex plug is required to secure the 43347 RTD into the 41003-5 radiation shield's base.
Orderable41322
10-Plate Shield Adapter for Use with 107, 108, 109, or HMP60
The 41322 adapter is required to install a 107, 108, or 109 probe in the 41003-5.
Orderable6637
Hex Adapter Plug
The 6637 Hex Adapter Plug can be used to install the HygroVue™10 Digital Temperature and Relative Humidity Sensor in the R. M. Young 41003-5 10-plate or 41005-5 14-plate solar radiation shield. It can also be used with the 41381 extension tube to mount a HMP60, HMP50, or CS500 temperature and relative humidity probe in the higher part of the 41003-5 or UT12VA solar radiation shield.
Orderable
Compatibility
The 41003-5 attaches to a crossarm, mast, or user-supplied pipe with a 1.0 to 2.1 in. OD.
Compatible Products
(7)109
Temperature Probe
OrderableNotesThe 41322 adapter is required to install a 109 probe.
43347
RTD Temperature Probe
OrderableNotesThe 27251 hex plug is required to secure the 43347 RTD into the radiation shield's base.
HMP60
Air Temperature and Relative Humidity Sensor
OrderableNotesFor the HMP60, the 41322 adapter can be used to mount the sensor in the lower part of the shield. Alternatively, a 41381 extension tube and the 6637 hex plug can be used to mount the HMP60 in a higher part of the shield; this configuration also requires the #18278 cable.
EE181
Air Temperature and Relative Humidity Sensor
OrderableNotesThe 15823 hex plug is required to mount the EE181 in the 41003-5.
107
Temperature Probe
OrderableNotesThe 41322 adapter is required to install a 107 probe.
108
Temperature Probe
OrderableNotesThe 41322 adapter is required to install a 108 probe.
HygroVue 10
Digital Temperature and Relative Humidity Sensor with M12 Connector
OrderableNotesCompatible with the use of the 6637 Hex Adapter Plug.