OBS-3+ Pricing Details
Educational Discounts: Yes Quantity Discounts: Yes Restockable: Yes Warranty: 1 year
Educational Discounts: Yes Quantity Discounts: Yes Restockable: Yes Warranty: 1 year
| Model | Description | |||
| OBS-3+ | Turbidity Sensor(Carrying Case Not Included) | |||
| Body Type Options (hide details) | ||||
| -SB | -SB Stainless Steel Body | |||
|
An OBS-3+ turbidity sensor housed in this stainless-steel body can only be submerged in fresh water at a maximum depth of 500 m. If an OBS-3+ with a stainless steel body is submerged in salt water, the warranty will be void.
|
||||
| -TB | -TB Titanium Body | |||
|
An OBS-3+ turbidity sensor housed in this titanium body can be submerged in either fresh or salt water at a maximum depth of 1500 m.
|
||||
| Output Options (hide details) | ||||
| -2.5 | -2.5 0-2.5V Output | |||
|
The -2.5 option supports our CR200(X)-series, CR510, or CR10(X) dataloggers. Both channels have an output range of 0 to 2.5 V.
|
||||
| -5 | -5 0-5V Output | |||
|
The -5 option supports our CR800, CR850, CR1000, CR3000, CR5000, and CR9000(X) dataloggers. Both channels have an output range of 0 to 5 V.
|
||||
| -20 | -20 4-20mA Output | |||
|
With the -20 option, the low channel has an output range of 4-20 mA, and the high channel has an output range of 0 to 5 V. A CURS100 is required for our dataloggers to read the 4-20 mA output.
|
||||
| Turbidity Range Options (hide details) | ||||
| -T1 | -T1 0-250 & 0-1000 NTUs | |||
|
Measures the lower range of 0 to 250 NTUs or higher range of 0 to 1000 NTUs.
|
||||
| -T2 | -T2 0-500 & 0-2000 NTUs | |||
|
Measures the lower range of 0 to 500 NTUs or higher range of 0 to 2000 NTUs.
|
||||
| -T3 | -T3 0-1000 & 0-4000 NTUs | |||
|
Measures the lower range of 0 to 1000 NTUs or higher range of 0 to 4000 NTUs.
|
||||
| -T4 | -T4 0-2000 & 0-4000 NTUs | |||
|
Measures the lower range of 0 to 2000 NTUs or higher range of 0 to 4000 NTUs.
|
||||
| -T5 | -T5 0-4000 & 0-4000 NTUs | |||
|
Measures the range of 0 to 4000 NTUs on both channels. The -T5 option allows a channel with a 4-20 mA output (OBS-3+-20) to measure up to 4000 NTUs.
|
||||
| Common Accessories | ||||
| 21098 | OBS-3+ or OBS300 Carrying Case (Holds 2) | |||
|
The 21098 provides a carrying case that holds two sensors.
|
||||
| 21094 | OBS-3+ or OBS300 Cable, 5m (16ft) | |||
|
Campbell Scientific offers a choice of seven cables for attaching the OBS-3+ to the datalogger. The cables differ in their length. The 21094 provides a 5-m length.
|
||||
| 21307 | OBS-3+ or OBS300 Cable, 10m (32.8ft) | |||
|
Campbell Scientific offers a choice of seven cables for attaching the OBS-3+ to the datalogger. The cables differ in their length. The 21307 provides a 10-m length.
|
||||
| 21308 | OBS-3+ or OBS300 Cable, 15m (49.2ft) | |||
|
Campbell Scientific offers a choice of seven cables for attaching the OBS-3+ to the datalogger. The cables differ in their length. The 21308 provides a 15-m length.
|
||||
| 21309 | OBS-3+ or OBS300 Cable, 20m (65.6ft) | |||
|
Campbell Scientific offers a choice of seven cables for attaching the OBS-3+ to the datalogger. The cables differ in their length. The 21309 provides a 20-m length.
|
||||
| 21310 | OBS-3+ or OBS300 Cable, 25m (82ft) | |||
|
Campbell Scientific offers a choice of seven cables for attaching the OBS-3+ to the datalogger. The cables differ in their length. The 21310 provides a 25-m length.
|
||||
| 21311 | OBS-3+ or OBS300 Cable, 30m (98.4ft) | |||
|
Campbell Scientific offers a choice of seven cables for attaching the OBS-3+ to the datalogger. The cables differ in their length. The 21311 provides a 30-m length.
|
||||
| OBS-3+CBL-L | OBS-3+ or OBS300 Sensor Cable | |||
|
Campbell Scientific offers a choice of seven cables for attaching the OBS-3+ to the datalogger. The cables differ in their length. The OBS-3+CBL-L has a user-specified length; lengths between 31 and 1000 meters can be ordered. A user-specified cable length takes more time to manufacture. The delivery time of the OBS-3+CBL-L is four to six weeks.
|
||||
| Cable Length (hide details) | ||||
| -L | m per sensor cable | |||
|
Campbell Scientific offers a choice of seven cables for attaching the OBS-3+ to the datalogger. The cables differ in their length. The OBS-3+CBL-L has a user-specified length; lengths between 31 and 1000 meters can be ordered. A user-specified cable length takes more time to manufacture. The delivery time of the OBS-3+CBL-L is four to six weeks.
|
||||
| CURS100 | 100 Ohm Current Shunt Terminal Input Module | |||
|
The CURS100 is required for our dataloggers to read the 4-20 mA output.
|
||||
| HYDRO-WIPER-C | OBS-3+ Battery Powered Mechanical Wiper, 1M (3ft) Cable | |||
|
This battery-powered wiper helps ensure accurate measurements by preventing algae and other fouling from covering the probe's lens. The HYDRO-WIPER-C includes an integrated timer for turning the wiper on and off. Cable length is 1 meter.
|
||||
| HYDRO-WIPER-D | OBS-3+ 12Vdc Datalogger Controlled, Mechanical Wiper, 5M (16ft) Cable | |||
|
The HYDRO-WIPER-D uses the datalogger's power supply, has a 5-m cable, and is controlled by the datalogger. The datalogger typically activates the wiper to remove algae and other fouling before each measurement.
|
||||
| HYDRO-WIPER-D-L | OBS-3+ 12Vdc Datalogger Controlled, Mechanical Wiper | |||
|
The Hydro-Wiper-D-L is essentially the same wiper as the HYDRO-WIPER-D, except it has a user-specified cable length. A user-specified cable length takes more time to manufacture. The delivery time for the Hydro-Wiper-D-L is four to six weeks.
|
||||
| Cable Length (hide details) | ||||
| -L | m cable per wiper | |||
|
The Hydro-Wiper-D-L is essentially the same wiper as the HYDRO-WIPER-D, except it has a user-specified cable length. A user-specified cable length takes more time to manufacture. The delivery time for the Hydro-Wiper-D-L is four to six weeks.
|
||||
| 20915 | OBS Sensor 5-Point Sedimentation Calibration (User Must send in Sediment Sample) | |||
|
Campbell Scientific will perform a 5-point sedimentation calibration for an OBS-3+ turbidity sensor. The customer must send Campbell Scientific a dry sample of sediment from the water that will be monitored.
|
||||
| Replacement Parts | |
| 20986 | O-Ring .676 ID .07 Wide Nitrile 2-017 |
|
This o-ring comes attached to the OBS-3+ Turbidity Sensor. The 20986 may be purchased to replace a lost or damaged o-ring.
|
|
| Services | |
| 20914 | OBS-3+/OBS-3A 3-Point Turbidity Recalibration w/Documentation |
|
When the 20914 is ordered, Campbell Scientific will perform a 3-point turbidity recalibration on the OBS-3+ sensor. All factory recalibrations require an RMA (Returned Material Authorization).
|
|
| 20915 | OBS Sensor 5-Point Sedimentation Calibration (User Must send in Sediment Sample) |
|
When the 20915 is ordered, Campbell Scientific will perform a 5-point sedimentation calibration for an OBS-3+ turbidity sensor. The customer must send Campbell Scientific a dry sample of sediment from the water that will be monitored.
|
|
Resources and Links
Related Documents
Ships With
(1) Calibration Certificate