This product is no longer available and has been replaced by: HMP60-L. Some accessories, replacement parts, or services may still be available.
Sections:
Other Accessories,
Replacement Parts
This product is currently unavailable for orders.
| Other Accessories | |
| 41303-5A | RM Young 6-Plate Gill Solar Radiation Shield |
|
The 41303-5A provides a six-plate naturally-aspirated radiation shield that houses one HMP50 probe. Its louvered construction allows air to pass freely through the shield thereby keeping the probe at or near ambient temperature. The 41303-5A attaches to a crossarm, mast, or user-supplied pipe with a 1.0" to 2.1" OD.
|
|
| 41003-5 | RM Young 10-Plate Gill Solar Radiation Shield |
|
The 41003-5 10-plate radiation shield can be used instead of the 41303-5A six-plate shield, but additional hardware is required (see below).
|
|
| 41322 | RM Young 10-Plate Shield Adapter for Use w/107, 108, 109, or HMP50 |
|
The 41322 adapter plate is used to mount an HMP50 probe in the lower part of a 41003-5 10-plate radiation shield.
|
|
| 6637 | Split Nut Plug for 43347 |
|
The 6637 split nut plug along with the 41381 extension tube allow the HMP50 to be mounted in the higher part of the 41003-5 10-plate radiation shield. This nut is used instead of the split nut provided with the 41003-5. The #18278 cable is also required for this mounting configuration.
|
|
| 41381 | RM Young 10-Plate Shield Extension Tube for use w/CS500 or HMP50 |
|
The 41381 extension tube along with the 6637 split nut plug allow the HMP50 to be mounted in the higher part of a 41003-5 10-plate radiation shield. The #18278 cable is also required for this mounting configuration.
|
|
| Replacement Parts | ||||
| HMP50CBL-L | Replacement HMP50-L Cable | |||
|
The HMP50CBL connects the HMP50 sensor head with input and power terminals on the datalogger.
|
||||
| HMP50CBL-L Options (hide details) | ||||
| -L | ft per sensor cable | |||
|
The HMP50CBL connects the HMP50 sensor head with input and power terminals on the datalogger.
|
||||
| Cable Termination Options (hide details) | ||||
| -PT | -PT w/Tinned Wires | |||
|
The HMP50CBL connects the HMP50 sensor head with input and power terminals on the datalogger.
|
||||
| -PW | -PW w/Pre-Wire Connector | |||
|
The HMP50CBL connects the HMP50 sensor head with input and power terminals on the datalogger.
|
||||
| 9598 | Replacement RH Chip for HMP60, HMP50, or CS500 | |||
|
The 9598 RH Chip is field-replaceable, as needed, eliminating the downtime typically required for the recalibration process. Chip replacement is recommended every 2 to 3 years depending on the application.
|
||||
Resources and Links


