The HFP01SC consists of a thermopile and a film heater. The thermopile measures temperature gradients across the plate. During the in-situ field calibration, the film heater is used to generate a heat flux through the plate. The amount of power used to generate the calibration heat flux is measured by the datalogger. Each plate is individually calibrated, at the factory, to output flux.

Self-calibration corrects for errors due to differences in thermal conductivity between the sensor and surrounding medium, temperature variations, and slight sensor instabilities.

HFP01SC-L Specifications

  • Sensor Type: Thermopile with film heater
  • Sensitivity (nominal):
    50 μV W-1 m-2
  • Nominal Resistance: 2 W
  • Temperature Range: -30° to +70°C
  • Expected Accuracy: ±3% of reading
  • Heater Resistance: 100 ohms (nominal)
  • Heater Voltage Input:
    9 to 15 Vdc
  • Heater Voltage Output:
    0 to 2 Vdc
  • Duration of Calibration:
    ±3 minutes @ 1.5 Watts;
    typically performed every 3 to 6 hours
  • Average Power Consumption:
    0.02 to 0.04 W
  • Plate Thickness: 5 mm (0.20 in.)
  • Plate Diameter: 80 mm (3.15 in.)
  • Weight without cable: 200 g (7.05 oz)