Standard Enclosures / ENC10/12R
ENC10/12R Raised Lid Enclosure, 10 x 12 inches

Overview

This enclosure is similar to the ENC10/12, except it has a raised lid. The raised lid allows taller peripherals to reside in it. The ENC10/12R typically houses a smaller data logger, power supply, and a small peripheral. It can also house remotely located peripherals such as multiplexers.

Read More

Benefits and Features

  • White, UV-stabilized enclosure reflects solar radiation—reducing temperature gradients inside the enclosure without requiring a separate radiation shield

Images

Backplate that is used inside the enclosure

CAD Files:

Detailed Description

The ENC10/12R's backplate is prepunched with half-inch-on-center holes suitable for attaching a data logger, power supply, and a communications or measurement and control peripheral.

The ENC10/12R is shipped with the 7363 enclosure supply kit that consists of desiccant, a humidity indicator card, cable ties, wire tie tabs, putty, grommets, screws, and PVC coupling. Additionally, Campbell Scientific offers a CS210 Enclosure Humidity Sensor for monitoring relative humidity inside of the enclosure. (See Ordering Info on the web page.)

Specifications

Construction Fiberglass-reinforced polyester enclosure with door gasket, external grounding lug, stainless-steel hinge, and lockable hasps
Color White (Reflects solar radiation, reducing temperature gradients inside the enclosure without using a separate radiation shield.)
Enclosure Classification NEMA 4X (before being modified for cable entry, conduit, or ground lug)
Number of Cable-Entry Seals 1 medium, 2 small
Dimensions
  • 30.5 x 25.4 x 14 cm (12 x 10 x 5.5 in.) internal
  • 28.42 x 23.44 x 15.09 cm (11.19 x 9.23 x 5.94 in.) internal under the lid space
  • 34.06 x 29.03 x 16.76 cm (13.41 x 11.43 x 6.6 in.) external
Weight 4.1 kg (9 lb)

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired) Although the CR1000 is compatible, this data logger can only fit inside the ENC10/12R if it is mounted vertically rather than horizontally.
CR10X (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR295X (retired)
CR300
CR3000 (retired) The ENC10/12R is compatible with the CR3000. Similar to the CR800/CR850 and CR1000, the CR3000 must be mounted vertically rather than horizontally. No space remains in the enclosure for additional peripherals.
CR350
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired) Although the CR800 is compatible, this data logger can only fit inside the ENC10/12R if it is mounted vertically rather than horizontally.
CR850 (retired) Although the CR850 is compatible, this data logger can only fit inside the ENC10/12R if it is mounted vertically rather than horizontally.
CR9000 (retired)
CR9000X (retired)

Measurement and Control

Product Compatible Note
SDM-SIO4 (retired)

Mounting Equipment

Product Compatible Note
CM500 (retired)
CM505
CM510
CM515

Additional Compatibility Information

Peripherals

Retired peripherals that won’t fit in the same ENC10/12R enclosure as the data logger/power supply include the AVW4, AM416, COM100, CR10KD, DC1765, and RC35.


Frequently Asked Questions

Number of FAQs related to ENC10/12R: 14

Expand AllCollapse All

  1. The terminals do not need to be replaced. Just sand or file the corrosion away, exposing clean copper, and the fittings will continue to be functional.
  2. Our fiberglass enclosures can withstand very cold locations, and their fiberglass/plastic construction is very resistant to corrosion.
  3. If you purchased a Stahlin enclosure from Campbell Scientific and it has a failed gasket, we can help you. We will need you to provide an image of the failed gasket, verify the size of your enclosure, and provide your contact information. We can then arrange to have a replacement gasket sent to you from Stahlin. For assistance, contact Technical Support at 435.227.9100.

  4. It depends on the device. Most devices have built-in mounting flanges, but some items require a separate mounting bracket.
  5. There is not an easy way to calculate how much desiccant is needed in an enclosure or how quickly the desiccant will need to be replaced. The following conditions affect the replacement interval:

    • How much humidity the enclosure is exposed to
    • The size of the enclosure
    • How often the enclosure door is opened and how long the door remains open
    • How airtight the enclosure is

    It may be advantageous to use more than one desiccant packet at a time inside an enclosure. Campbell Scientific recommends keeping an extra supply of desiccant on hand for as-needed replacement in the enclosure.

  6. Backplates are available in sizes designed to fit in Campbell Scientific enclosures: 10 x 12 in., 12 x 14 in., 14 x 16 in., and 16 x 18 in.

  7. Yes. In the Ordering information area of the enclosure's web page, navigate to the Replacement Parts section. The Universal Backplate for the enclosure is listed there.

  8. Use a router with a fine-toothed bit. A hole saw will also work, but the edges will not be as clean as from using a router.
  9. Yes. The CD100 mounts in an enclosure door and supports all of the CR1000KD capabilities. With the CD100, historic and real-time data can be read, and instructions can be entered without opening the enclosure door.

    Other available options that display real-time data only are the CD295 and CD294.

Privacy Policy Update

We've updated our privacy policy.  Learn More

Cookie Consent

Update your cookie preferences.  Update Cookie Preferences