EC150 Open-Path Gas Analyzer
Campbell Scientific’s EC150 is an open-path analyzer specifically designed for eddy-covariance flux measurements. As a stand-alone analyzer, it simultaneously measures absolute carbon-dioxide and water-vapor densities,...
CABLEPCBL-L 2-Conductor 16-AWG Power Cable
CABLE4CBL-L 4-Conductor 22-AWG Cable w/Drain Wire
CABLE2TP-L 2 Twisted Pair 22AWG Cable w/Drain
The CABLE2TP-L is a two-twisted pair, 22-AWG cable that has a Santoprene® jacket. Insulation colors of the twisted pairs are red/black and green/white. An aluminum...
CABLE3TP-L 3 Twisted Pair 22 AWG Cable w/Drain
The CABLE3TP is a three-twisted pair, 24 AWG cable that has a Santoprene® jacket. Insulation colors of the twisted pairs are red/black, green/white, and blue/yellow....
26390 EC150 Zero & Span Shroud Kit
The 26390 IRGASON/EC150 Zero and Span Shroud Kit is offered for customers who want to perform their own zero and span. The zero and span...
16764 CSAT3 Carrying Case (no foam)
10080 CSAT3 TC Cover
HMP155A-L Temperature and Humidity Probe
The HMP155A probe monitors relative humidity (RH) for the range of 0 to 100% RH and temperature for the range of -80° to +60°C. It...
SW12V Power Switch
The SW12V is a power switch that allows a datalogger to determine whether 12 Vdc power is passed onto an external device.
KH20 Krypton Hygrometer
The KH20 is a highly sensitive hygrometer designed for measurement of rapid fluctuations in atmospheric water vapor, not absolute concentrations. It is typically used together...
CM204 4-foot Crossarm with Bracket
The CM204 is a crossarm that attaches to an instrumentation tower or tripod. It provides a rugged, weather-resistant sensor mount for one or two sensors....
18048 3/4 IPS Aluminum Pipe, 12 inches Long
6332 3/4 IPS Unthreaded Pipe Aluminum, 10 inches Long
1049 0.75- x 1-inch NU-RAIL Crossover Fitting
The 1049 connects a 1-inch pipe to a 0.75-inch pipe. The 1049 is typically used to attach a sensor with a 0.75-inch pipe mount to...
1017 0.75" x 0.75" NU-RAIL Crossover Fitting
Resources and Links
0 items in your Quote List.
View
About Open Path EC System Sensors and Mounts
Open path eddy covariance systems incorporate eddy covariance techniques to calculate water vapor, carbon dioxide, and heat flux measurements. Customers purchase the individual components of the open-path eddy covariance system. An open-path eddy covariance system typically uses a sonic anemometer for absolute wind measurements, a gas analyzer for CO2 and H2O molar density measurements, a Kyrpton hygrometer for H2O density measurements, and a fine wire thermocouple for absolute temperature measurements.